Contact Us

TPS22950YBHR

Brand: Texas Instruments
Texas Instruments TPS22950YBHR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS22950YBHR — Power Management & Signal Chain | Superb Automation

TPS22950YBHR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS22950YBHR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS22950YBHR: 5.5 V 3.2 A load switch with adjustable current limit in a six ball chip scale package

TPS22950YBHR is a load switch with 34 milliohm on-resistance, a current limit set by one resistor from 50 mA to 3.5 A, reverse current blocking and a fault flag, used to protect a rail or to sequence it in a DSBGA (YBH) body of 6 pins. It works from 1.8 V to 5.5 V, passes 3.2 A through 34 milliohm at 5 V and 41 milliohm at 3.3 V, and limits the output current to a value set by a resistor on the ILIM pin anywhere from 50 mA to 3.5 A. Turn on is deliberately slow at 800 microsecond at 5 V to keep the inrush inside the limit.

Order code and package

Order code read outTPS22950 YBH R: load switch TPS22950 with auto retry current limit, YBH six ball chip scale package, R large tape and reel
PackageDSBGA (YBH), 6 balls, 1.106 mm by 0.706 mm, ball pitch 0.4 mm, 180 mm reel
Carrier in the vendor addendum3000 pieces on a large reel; the leaded alternative is the six pin SOT body in the TPS22950C order code
Moisture levelLevel 1, 260 degrees peak reflow, unlimited floor life
Ball materialTin silver copper, quoted as SNAGCU
Temperature rangeJunction minus 40 to plus 125 degrees operating, minus 40 to plus 150 absolute maximum
Absolute maximum6 V on the input, 6 V on the ON pin, 6 V on the fault pin, and a junction limit of 150 degrees

Electrical parameters that decide the application

Input range1.8 V to 5.5 V, so the switch works on a 1.8 V, 2.5 V, 3.3 V or 5 V rail
Output current3.2 A continuous, with an adjustable current limit from 50 mA to 3.5 A set by a resistor to ground on the ILIM pin
On-resistance34 milliohm typical and 41 milliohm maximum at 5 V and 25 degrees, 41 milliohm typical and 51 maximum at 3.3 V, rising to 49 and 54 milliohm at 5 V over the temperature range
Turn on time800 microsecond typical at 5 V and 550 microsecond at 3.3 V, which is the slow ramp that keeps the inrush into the load capacitance below the current limit
Quiescent current44 microamp typical and 60 microamp maximum at 25 degrees with the switch on and no load, 60 microamp maximum over the full range
Shutdown current0.2 microamp typical and 0.4 microamp maximum at 25 degrees, rising to 9 microamp at 85 degrees and 46 microamp at 125 degrees because of the leakage of the devices around it
Fault responseThe TPS22950 retries automatically after a current limit event, while the TPS22950L latches off so that the fault has to be cleared by cycling the ON pin
Fault flagAn open drain FLT pin pulls low during thermal shutdown or a reverse current condition, so a controller can count faults rather than infer them
Reverse current blockingAlways on in the TPS22950, with no pin to configure, so a load cannot push current back into a collapsed input
Quick output discharge150 ohm internal path that discharges the output when the switch is turned off, which stops a rail from floating down slowly
ON pinHigh above 1 V, low below 0.35 V, with a 500 kohm pulldown when the pin is low and 50 nanoamp maximum leakage when it is high, so it can be driven from a low power logic output
Thermal135.8 degrees per watt junction to ambient for the YBH body, against 104.8 for the leaded SOT body
Thermal shutdownThe switch turns off when the junction exceeds its limit and the fault pin reports it, which is the guard against a sustained overcurrent that the current limit alone would not clear

Versions, pins and the leaded alternative

TPS22950YBHRthe part on this page, auto retry current limit, six ball chip scale package, 3000 pieces on a 180 mm reel
TPS22950Lthe latch off version, where a current limit event turns the switch off until the ON pin is cycled, chosen when a fault must not be retried automatically
TPS22950C in the SOT bodythe leaded six pin alternative at 2.90 mm by 2.80 mm with 104.8 degrees per watt, chosen when the board cannot take a chip scale part or when rework access matters
ILIM pinthe current limit setting resistor, which covers 50 mA to 3.5 A and therefore allows the same part to protect a 100 mA sensor rail or a 3 A peripheral rail
ON pin pulldown500 kohm internal, which keeps the switch off when the driving pin is floating rather than letting the rail come up uncontrolled

Points to check before this part goes on a BOM

A load switch with adjustable current limit is a different component from a fuse and from a fixed load switch, and the difference shows up at start up. The 800 microsecond ramp at 5 V means the inrush into the load capacitance is spread over a time long enough that the current limit does not trip, so a rail with 100 microfarad of capacitance charges at about 0.6 A instead of a spike limited only by the ESR. That is what allows the limit to be set close to the load current rather than far above it.

The choice between the auto retry and the latch off version is a system decision. Auto retry suits a peripheral that may be hot plugged and where a transient overcurrent should clear itself; latch off suits a load where a repeated fault would be dangerous or where the controller needs to know the fault happened and decide what to do. Both carry the same part number root, so the difference is one letter and it has to be checked on the bill of materials rather than assumed from the family name.

Reverse current blocking is the feature that matters when a rail is fed from two sources. If the input collapses while the output is held up by a battery or a large capacitor, a switch without blocking turns into a path back into the collapsed rail and pulls the whole node down. The TPS22950 blocks that condition automatically and reports it on the fault pin, which is a useful signal for a controller that wants to know why a rail sagged.

The shutdown current is specified at three temperatures and the numbers are far apart: 0.2 microamp at 25 degrees, 9 microamp at 85 and 46 microamp at 125. That is not a defect, it is the leakage of the devices around the switch rising with temperature, and it means a battery powered product that has to hold its sleep current over a hot environment should be quoted against the 85 or 125 degree figure rather than the room temperature one.

The quiescent current of 44 microamp with the switch on deserves a note because it is higher than a load switch with a fixed limit. The adjustable limit and the reverse blocking circuits are what draw it, and on a rail that is on all the time it is a real cost. Where a 3.2 A switch is being used to pass 20 mA, the current consumption of the switch itself exceeds the load, and a simpler part or a direct connection is the better answer.

The chip scale body at 135.8 degrees per watt is not a good thermal path, and the 34 milliohm on-resistance is what makes it workable. At 3 A the switch dissipates about 0.3 W, which is 41 degrees of rise in the YBH body and 31 in the SOT body. A build that runs 3 A continuously at a 85 degree ambient is at the edge in the chip scale part and comfortable in the leaded one, which is the practical reason the leaded version exists.

Where this order code fits

Protects and sequences peripheral rails in personal electronics, notebooks, set top boxes, industrial controllers and battery powered instruments, particularly where a 5 V or 3.3 V rail has to be switched into a load with a large input capacitance or protected against a short. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

How is the current limit set? By a resistor from the ILIM pin to ground, covering 50 mA to 3.5 A. The setting is what the switch will hold into an overload, and the slow turn on ramp is what keeps the inrush below that value at start up.

What is the difference between the TPS22950 and the TPS22950L? The fault response. The plain part retries automatically after a current limit event; the L version latches off and needs the ON pin cycled before the load is powered again.

Does it block reverse current? Yes, always on with no pin to configure, and the fault pin reports the condition. That matters when the output is held up by a battery or a second supply while the input collapses.

What is the on-resistance? 34 milliohm typical and 41 maximum at 5 V and 25 degrees, 41 typical at 3.3 V, rising to 54 milliohm maximum at 5 V over the full temperature range.

Is the chip scale package thermally adequate at 3 A? It dissipates about 0.3 W at 3 A and the YBH body is 135.8 degrees per watt, so the rise is roughly 41 degrees. That is acceptable at a moderate ambient and marginal at 85 degrees, where the leaded SOT body at 104.8 degrees per watt is the safer choice.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.