TMP6331DYAR
Product Specifications
TMP6331DYAR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP6331DYAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP6331DYAR: a 100 k linear thermistor that behaves like a resistor, not a curve
TMP6331DYAR is a silicon based thermistor with a nominal 100 k resistance at 25 degrees and a positive temperature coefficient of 6400 parts per million per degree. It is the 0603 body member of the TMP63 family, two pins, no bias circuit to linearise and no calibration table to fit. The point of the part is that the resistance against temperature curve is a straight line within a fraction of a percent, so a product can convert a reading with a multiply and an add instead of a lookup table.
The tolerance is plus or minus 1 percent maximum between 0 and 70 degrees, and the operating window is minus 40 to plus 150 degrees in the 0603 body. That window is what separates this part from the NTC thermistors it replaces: a 10 k NTC that is accurate at 25 degrees has lost most of its sensitivity by 125 degrees, while this part still moves about 640 ohms per degree at the top of its range.
The numbers below come from SNIS211D, revised November 2020, and from the orderable addendum. They are the ones we check when a customer forwards a BOM that lists a thermistor without a tolerance, because the difference between a 1 percent part and a 5 percent part is invisible until the first calibration run.
Why a linear part changes the conversion
An NTC divider produces a voltage that follows an exponential, so a processor either carries a lookup table with interpolation or fits a Beta equation. Both cost flash and both need the individual part tolerance to be handled. A linear thermistor produces a voltage that is a straight line, so the conversion is a slope and an offset, and a single point calibration removes the offset term.
The linearity is not perfect, and the document prints the second order term in the resistance table rather than in the feature list. For a protection threshold the error is irrelevant. For a measurement that has to read within half a degree across a wide window, the residual curvature is a correction term of a few tenths of a degree, and the vendor supplies the table to compute it.
| Function | silicon linear thermistor, positive temperature coefficient |
| Nominal resistance | 100 k at 25 degrees Celsius |
| Resistance tolerance | plus or minus 1 percent maximum from 0 to 70 degrees |
| Temperature coefficient | plus 6400 ppm per degree at 25 degrees |
| Coefficient tolerance | 0.2 percent typical across the temperature range |
| Operating window | minus 40 to plus 150 degrees Celsius in the 0603 body |
| Bias current | 0 to 40 microamps recommended, 20 microamps in the electrical table |
| Voltage across the part | 0 to 5.5 V recommended, 6 V absolute maximum |
| Current limit | 450 microamps absolute maximum |
| Thermal response | 0.6 seconds to 63 percent in stirred liquid, 0402 body |
| Long term drift | 0.3 percent typical over 600 hours at 150 degrees |
| Fail-safe behaviour | resistance falls on a short circuit failure, so the reading goes low |
| Thermal resistance | 742.9 degrees per watt junction to ambient, 0603 body |
| ESD | plus or minus 2000 V human body, plus or minus 1000 V charged device |
| Package | SOT-5X3, DYA, 0603 footprint, two pins |
| Carrier | 3000 pieces on a large reel |
| Moisture level | level 1 at 260 degrees, unlimited floor life |
| Marking | 1HG |
Bias arithmetic that decides the divider
At 20 microamps the part drops 2 V, because 20 microamps through 100 k is 2 V. On a 3.3 V rail that leaves 1.3 V for the series resistor and the converter input, which is workable but tight, and it is the reason this resistance value suits a 5 V rail better than a 3.3 V rail. At 10 microamps the drop is 1 V and the divider has room to breathe on 3.3 V, at the cost of halving the signal slope.
With a matched 100 k series resistor on a 3.3 V rail the divider sits at 1.65 V at 25 degrees and moves about 5.28 mV per degree near that point. A 12 bit converter on the same 3.3 V reference resolves 0.806 mV per count, so one count is 0.153 degrees, which is finer than the 1 percent resistance tolerance can support. The converter is therefore never the limit, and the accuracy of the reference and the tolerance of the two resistors are.
Self heating is negligible and worth proving rather than assuming. At 20 microamps the dissipation is 40 microwatts, and with 742.9 degrees per watt the die sits 0.03 degrees above the board. Even at the 40 microamp limit the rise is 0.12 degrees, so a build can raise the bias current to gain signal without worrying about the sensor heating itself.
Fail-safe behaviour and why it matters in a medical build
The part is a positive coefficient device, and the document states a built-in fail-safe for short circuit failures: a shorted part reads as a low resistance, which in a divider reads as a low temperature. That direction is the safe one for a heater, where a false low reading means the heater keeps running until a second limit trips, and it is the unsafe one for a protection circuit that trips on high temperature. The firmware has to know which direction the failure moves and put the independent limit on the other side.
The other half of the fail-safe story is the open circuit case, which every two pin sensor shares: an open reads as a high resistance and therefore a high temperature. A firmware that cannot tell an open sensor from a hot one will report a fault as an alarm, which is acceptable, or an alarm as a fault, which is not.
Placement and response time
The 0603 body has a thermal mass small enough that the response in stirred liquid is 0.6 seconds in the 0402 member of the family, and slightly slower in the 0603. That speed is only useful if the part is placed on the thing being measured rather than on the board near it. A thermistor next to a power inductor reads the inductor, and no amount of calibration fixes that.
The recommended arrangement is the part on a short trace with a ground pour that does not connect to a heat source, and a bias resistor of the same value placed close so that both see the same board temperature. If the bias resistor drifts with temperature the divider moves even when the sensor is stable, and a 100 ppm per degree resistor contributes a small fraction of a degree over a 100 degree window, which is acceptable for most builds and not acceptable for a calibration reference.
Where it fits in a medical or industrial build
Temperature monitoring in HVAC, thermostats, industrial control, appliances, display backlights, motor control and chargers is the list the document gives. In our own builds the part appears in patient warming equipment, in laser diode temperature control and in battery packs, in all three cases because the linear output makes the firmware simple and the 150 degree window covers a fault condition.
For a medical device the 1 percent tolerance and the 0.3 percent drift figure are the two numbers an auditor will ask about, and the medical device component page collects the parts we keep for that class of build. The incoming inspection plan page describes how we sample a thermistor reel, which for this part means a resistance check at two temperatures rather than a visual check.
Ordering and incoming checks
The orderable row prints TMP6331DYAR as active and in production, SOT-5X3 with two pins, 3000 pieces on a large reel, moisture level 1 at 260 degrees and marking 1HG. The DECT row is the 0402 body on a 10000 piece reel and the DECR row is the same body in a smaller carrier, so a purchase order that names only the family can land on the wrong footprint. The 0603 body and the 0402 body are not interchangeable on a board.
Incoming inspection is a resistance measurement at 25 degrees on a sample of ten, compared against the tolerance window, plus a check of the marking and the reel label. Because the part is level 1, no baking is needed, which removes a scheduling step that the older NTC parts often carry.
For a build that needs the thermistor, the bias resistor and the connector on one line, the one stop BOM sourcing route keeps them together, which matters because the bias resistor tolerance decides the divider accuracy as much as the sensor does.
Three questions buyers ask about this string
Can it replace a 10 k NTC without a firmware change? No. The resistance at 25 degrees is ten times higher, the slope has the opposite sign and the curve is linear, so the divider and the conversion both change.
Is the 0603 body available with a higher tolerance? One percent is the published grade for this family. A tighter part would have to come from a different technology, and the calibration route is usually cheaper than a tighter sensor.
What happens at 150 degrees? The part continues to behave as a resistor, but it is at the top of its specified window and the drift figures no longer apply. A product that has to survive a fault at 150 degrees should be built so that the sensor is not the only limit.