TMP6131QDYARQ1
Product Specifications
TMP6131QDYARQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP6131QDYARQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP6131QDYARQ1 automotive grade silicon linear thermistor in the 0603 SOT-5X3 body
The TMP6131QDYARQ1 is the automotive row of the TMP61 silicon thermistor family in the 0603 SOT-5X3 body, with the same positive coefficient element as the catalog part and a nominal resistance of 10 kilohm at 25 degrees. The Q1 letter is the qualification row rather than a different die, so the resistance to temperature curve that the board was validated against does not change when a program moves from the catalog part to the automotive one.
For a engineering team the practical value of the automotive row is the paperwork and the temperature grade, not new electrical behaviour. The element holds a 6400 ppm per degree coefficient at 25 degrees with 0.2 percent typical coefficient tolerance, plus or minus 1 percent on the nominal from 0 to 70 degrees and plus or minus 1.5 percent over the full range, and the SOT-5X3 body gives a footprint that most automotive assembly lines already run.
Key parameters taken from the TMP6131QDYARQ1 document
| Element | Silicon thermistor, positive temperature coefficient, 10 kilohm at 25 C |
| Tolerance | Plus or minus 1 percent maximum from 0 to 70 C, plus or minus 1.5 percent over minus 40 to 150 C |
| Coefficient | 6400 ppm per C at 25 C, 5910 at 85 C and 6220 at minus 35 C |
| Coefficient tolerance | 0.2 percent typical at 25 C, 0.4 percent typical at minus 35 C |
| Range | Minus 40 to plus 150 C, with fail-safe behaviour at the top of the range |
| Drift | 0.5 percent typical long term drift after 1000 hours at 150 C, 1.2 percent maximum in the 0603 body |
| Fail behaviour | A short to the supply raises the resistance, so the fault reads hot rather than cool |
| Body | SOT-5X3, DYA suffix, 0603 footprint, three terminals with one unused |
| Grade | Automotive Q1 row of the family, with the qualification and the change control that goes with it |
| Conversion | Resistance to temperature table from the vendor, generated by the family board tool |
| Response | Thermal response in the region of half a second in the small body, set by the thermal mass |
| Self heating | Low excitation power keeps the element close to the surface it is bonded to |
| Order code facts | TMP6131QDYARQ1, SOT-5X3 DYA body, tape and reel, automotive Q1 grade |
| Family | The same curve ships as TMP61 in the 0402 X1SON body and in a two pin TO-92S body |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The automotive row exists so that a program can keep one part number from prototype to series production without a re-qualification of the sensing element. What changes is the documentation trail: the Q1 row carries the qualification the customer's supplier approval asks for, and the change control that goes with it. A board that was validated on the catalog part and then moved to the Q1 row has to re-run the thermal and lifetime validation, because the grade changes the accepted operating envelope even when the silicon is the same.
The 0603 body is the one to choose when the assembly line already runs 0603 passives, because it uses the same feeder, the same nozzle and the same placement tolerance. The 0402 body saves space and responds faster and asks more of the line. On an automotive program where the board goes through a two sided reflow with a heavy thermal mass on one side, the larger body is easier to place and easier to inspect, and the difference in response time rarely matters at the temperatures that matter here.
Self heating is worth a calculation on an automotive board because the ambient inside an ECU is already high. The element is excited by a divider, and the power in the element is the square of the excitation voltage over its resistance. At 140 degrees the resistance is several times the 25 degree value, so the self heating falls as the part gets hot, which is the comfortable direction. The number to check is at the cold end, where the resistance is lowest and the current through the divider is highest, and where a cold start test may hold the divider on for a long time.
Because the output is a resistance, the diagnostic strategy can be built into the divider rather than into the software. Two resistors in series with the element give a window comparator that separates open, short and in range without a converter, and the positive coefficient means both fault directions land outside the in range window. That is a cheap way to satisfy a functional safety requirement on a temperature input, and it is the reason this family appears in automotive sensor interfaces that do not have a spare analogue channel.
- Resistance at 25 degrees against the 9.9 to 10.1 kilohm window, on the first article from each lot.
- Divider output across the full temperature range at the rail the ECU actually provides, cold crank included.
- Self heating at the cold end with the divider energised for the longest period the firmware allows.
- Open, short and in range diagnosis with the window comparator thresholds chosen for the actual divider.
- Placement and reflow record against the automotive process, including the second reflow pass.
- Traceability record from the reel label to the board serial, which is what the customer audit will ask for.
Which projects this part fits
This part fits automotive ECU and transmission control temperature sensing, battery pack and busbar monitoring, inverter and motor hot spot measurement, charger inlet temperature, and any automotive sensor interface that has to keep working from a cold crank to a hot soak. For SUPERB customers building automotive electronics and charging hardware it is the practical way to keep an analogue temperature input without an NTC calibration step, and the automotive row keeps the part number stable through the program.
Questions that come up before a purchase order is released
Is the Q1 part electrically identical to the catalog part?
The element and the curve are the same family. The qualification, the accepted operating envelope and the change control differ, and a program that moves between them has to re-run the validation that depends on those. Treating the two rows as interchangeable without that step is what produces a qualification finding late in a program.
Why a three terminal body for a two terminal element?
The extra terminal is a mechanical and routing convenience rather than an electrical one, and the document shows which pins carry the element. A routing that treats the third pin as a connection will short the divider, so the pin assignment has to be read from the document rather than inferred from the drawing.
What is the fail-safe direction?
A positive coefficient element rises in resistance as it heats, so a short to the supply pushes the divider output towards the supply and the reading fails high. That is the direction a protection circuit wants, because the failure looks like an over temperature and the system shuts down rather than continuing to run hot.
How does this compare with an NTC for accuracy over life?
The vendor prints 0.5 percent typical drift after 1000 hours at 150 degrees, with 1.2 percent maximum in the 0603 body. An NTC bead of similar cost drifts more and its curve is steeper at the cold end, so the same analogue front end resolves less temperature there. The trade is that the conversion table has to come from the vendor rather than from a standard beta formula.
Can the same divider feed a comparator and a converter?
Yes, and that is a common pattern: the converter is used for the control loop and the comparator, with a wider window, is used for the fault path. The two thresholds have to be set from the same resistance table, and the comparator window has to allow for the divider tolerance plus the element tolerance at the trip temperature.
How SUPERB handles this line
We supply the TMP6131QDYARQ1 from original reels with the automotive letter and the date code verified on the label, and we can provide the family document number with the shipment for the customer audit. Where a program needs the catalog body instead, the power management cross reference page lists the family by body and grade. For continuity over a long automotive program, component obsolescence management covers the options, and incoming inspection plan covers the incoming checks that catch a wrong grade before it reaches the line.