The TMP20AIDCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP20AIDCKR: analog output temperature sensor at 4 microampere in a 5 lead SC70
TMP20AIDCKR is a precision analog output temperature sensor with a linear voltage output in a SC70 body of 5 pins. It outputs a voltage that falls with temperature and needs no conversion, no register write and no clock, so a microcontroller reads it on an ADC channel and nothing else. The AIDCKR order code is the 5-lead SC70 on tape and reel.
Order code and package
| Order code | TMP20AIDCKR |
| Package | 5-lead SC70, 2.00 mm by 1.25 mm |
| Packing | tape and reel |
| Pins | V+, GND, VOUT, and two no connect pins in the 5-lead body |
| Output | analog voltage, negative slope with temperature |
| Interface | none, direct to an ADC input |
| Compatibility | pin compatible with the LM20 in the SC70 body |
Electrical parameters that decide the application
| Accuracy | plus or minus 2.5 degrees Celsius from minus 55 to plus 130 degrees |
| Supply | 2.7 V to 5.5 V, with 1.8 V operation between 15 and 130 degrees |
| Supply current | 4 microampere maximum |
| Output at 0 degrees | 1.8639 V at the parabolic transfer function |
| Slope | about minus 11.69 mV per degree Celsius at 25 degrees |
| Shutdown | below 0.5 V on V+, under 20 nA typical |
| Self heating | under 0.01 degrees Celsius at 4 microampere |
| Output impedance | a resistive output that needs a high impedance ADC input |
Family variants and how they differ
| TMP20 | the parabolic output part on this page |
| LM20 | the pin compatible predecessor with the same transfer curve |
| SOT-563 | the 6-lead body, 1.60 mm by 1.20 mm |
| SC70 | the 5-lead body on this order code |
Points to check before this part goes on a BOM
The transfer function is parabolic, not linear: the output is 1.8639 V at 0 degrees and the data sheet worked example gives 0.5520 V at 110 degrees, with a slope near the middle of the range of minus 11.69 mV per degree. A firmware routine that fits a straight line over the full range carries up to 1.41 degrees of error, which the data sheet states explicitly in the table of linear approximations.
For a narrow band the linear fit is much better. Over 20 to 30 degrees the residual is 0.004 degrees, over 35 to 45 degrees it is 0.004 degrees, and over minus 10 to 65 degrees it is 0.23 degrees. A product that only has to read a room temperature window can use one linear equation and skip the quadratic, and that is the case the table is written for.
The output is a voltage source with a finite output impedance, and the ADC that reads it has to have an input impedance high enough not to load it. A 12-bit converter with a 10 kohm sample network is fine; a 10 kohm potential divider placed directly on the output is not, because the divider current flows through the output stage and shifts the reading.
The 4 microampere maximum supply current limits self heating to under 0.01 degrees, which is why the part can sit inside a sealed enclosure without a correction term. A competitor part that draws 200 microampere dissipates 1 mW at 5 V, and in a small package that is a measurable offset that appears only after the product warms up.
Operation down to 1.8 V is limited to the 15 to 130 degree range. Below 15 degrees the output amplifier needs more headroom than a 1.8 V rail can give, so a battery product that has to read freezer temperatures must keep the rail at 2.7 V or higher over the whole range.
Below 0.5 V on V+ the part shuts down to under 20 nA typical. That is useful in a product that cycles its sensor rail, but the output does not go to a defined state during shutdown, so the ADC has to be gated rather than allowed to sample an unpowered node.
The 2.5 degree accuracy figure includes the part to part spread and the curvature over the full range. It does not include the ADC reference error or the divider error if one is used, so a system that claims 2.5 degrees has to spend some of that budget on a reference with better than 0.2 percent initial accuracy, which on a 3 V rail is 6 mV or about 0.5 degrees.
The SC70 and SOT-563 bodies are the smallest options and both need care on the board: the thermal pad is the die attach paddle and the part is a two terminal sensor in effect, so a ground plane connected to the GND pin pulls the die toward the board temperature. That is usually what a product wants, but a part placed next to a regulator reads the regulator and not the air.
The output is intended for a converter input with a high impedance sample network. A 100 nF capacitor from the output to ground filters pickup on a long trace and is within what the output stage can drive, but a 1 microfarad part turns the sensor into a slow filter that lags a real temperature change by seconds and hides a fast thermal fault.
A ratiometric measurement, where the converter reference and the sensor supply are the same rail, cancels the supply error in firmware. With a separate reference the supply error appears directly in the reading, and the 2.5 degree budget is spent on the regulator rather than on the sensor. The two arrangements give the same number only when the rail is exact.
The die sits on the package paddle, and the paddle is thermally connected to the pin frame. A sensor placed with its ground pin on a copper pour reads the pour, which is usually what a product wants; a sensor placed next to a switching regulator reads the regulator. The 0.01 degree of self heating is irrelevant beside a 20 degree board gradient.
The part has no configuration and no bus, which is also its limit: a product that wants two sensors has to spend two converter channels, and there is no way to identify which sensor is which. A digital sensor with an address solves that and costs a bus. The choice is a channel count decision as much as a cost one. A product that has to distinguish two nearby heat sources should give each sensor its own copper island and its own converter channel, because the package paddle couples the die to whatever copper it is soldered to, and that coupling is larger than the air temperature difference the product is trying to measure.
Where this order code fits
It is used in battery packs, handheld instruments, white goods and thermal monitoring where a microcontroller already has a spare ADC channel and no room for a digital bus. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
Does it need a pull up or a bus? No. It is a three terminal analog sensor: supply, ground and output. There is no address, no clock and no configuration register.
Can firmware use a straight line? Yes, over a narrow band. Over the full range the parabolic term matters and a linear fit carries up to 1.41 degrees of error, so the band has to be chosen deliberately.
Is it a drop-in for the LM20? In the SC70 body the pin arrangement matches the LM20, and the transfer function is the same shape. The accuracy and the supply range still have to be checked against the older part's data sheet.
What does it read at 0 and 110 degrees? 1.8639 V at 0 degrees and 0.5520 V at 110 degrees, which are the two points the data sheet uses to anchor the curve. Everything between them follows the parabola rather than a straight line.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.