Contact Us

SN65HVD1471DR

Brand: Texas Instruments
Texas Instruments SN65HVD1471DR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

SN65HVD1471DR — Power Management & Signal Chain | Superb Automation

SN65HVD1471DR

Texas Instruments — Power Management & Signal Chain

Product Overview

The SN65HVD1471DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

SN65HVD1471DR: a full duplex 3.3 V RS-485 transceiver with 16 kV contact ESD

The SN65HVD1471DR is a full duplex RS-485 transceiver on a 3.3 V rail, with separate driver and receiver pins so the transmit pair and the receive pair are independent. Its headline is protection: more than 30 kV human body model, more than 16 kV IEC 61000-4-2 contact discharge and more than 4 kV of fast transient burst, which is the set of events a cable in an industrial cabinet actually sees.

The 1471 member is fully enabled, with no driver or receiver enable pins, which suits a point to point or a bus where the transceiver is always listening and always able to talk. Data rate is 400 kbit/s, the receiver hysteresis is 70 mV, and the quiescent current is below 1.1 mA with a standby figure of 10 nA typical and under 5 uA maximum when both halves are disabled on the members that have enables.

Key data for the SN65HVD1471DR

DuplexFull duplex, separate A, B, Y and Z pins, no enable pins on this member
Rate400 kbit/s, the low speed member of the family, against 20 Mbps and 50 Mbps siblings
Loading1/8 unit load, up to 256 nodes on one bus segment
ProtectionAbove 30 kV HBM, above 16 kV IEC 61000-4-2 contact, above 4 kV IEC 61000-4-4 burst, glitch free power up and down
Receiver70 mV of hysteresis for noise rejection, wide common mode range for long cable runs
CurrentUnder 1.1 mA quiescent in operation, 10 nA typical and under 5 uA maximum in standby on the enabled members

Body, marking and reel data

BodyD, SOIC 8 at 4.90 mm by 3.91 mm, with an MSOP 8 at 3.00 mm by 3.00 mm in the same family
Reel2500 pieces on a large reel for the plain, .B and G4 rows, carrier tape 12.4 mm
MarkingVD1471 on the plain and G4 rows, HVD1473 on the .B row of the same order string, which is a marking slip in the vendor file
HandlingMoisture level 2 with 1 year floor life on the plain row, level 1 unlimited on the G4 row, so the two rows differ in bake rules
TemperatureMinus 40 C to 125 C on every published row, which is the extended industrial range

Where full duplex earns the extra two pins

Half duplex RS-485 shares one pair and turns the driver around between messages, which costs a turnaround delay and a bus arbitration scheme. Full duplex keeps a transmit pair and a receive pair apart, so a master can stream commands while a node streams data back. For a motion controller that has to send a position setpoint every millisecond and read an encoder in between, that separation is the difference between a working loop and a bus that always answers one cycle late.

The 400 kbit/s ceiling is deliberate. Lower edge rates travel further on the same cable, and a 1200 m run at 400 kbit/s is a normal industrial distance rather than an experiment. Where the cable is short and the data is heavy, the 20 Mbps and 50 Mbps members of the same family use the same board footprint, so the rate can be raised without a new board.

The protection figures are measured on the bus pins, not on the logic pins, which is where a cable discharge lands. A 16 kV contact event is a person touching the connector, and the IEC test repeats it ten times per polarity at each pin. That is the reason this family is chosen for equipment that is cabled and uncabled on a bench rather than in a rack.

Questions we get when this code is on a BOM

The question that decides the order is usually about the enable pins. The 1471 has none, so it cannot be tri-stated by the controller, which is fine on a dedicated pair and wrong on a shared bus where several nodes take turns. The 1470 and 1473 members carry active high driver enables and active low receiver enables, and the choice has to be made from the bus topology rather than from stock.

The second question is about moisture level. The plain row prints level 2 with a one year floor life, the G4 row prints level 1 with unlimited floor life, and both are the same silicon. A line that runs long shifts with open reels should order the row whose floor life matches its schedule, because a level 2 reel that sits out for a week needs a bake before reflow.

How SUPERB supports this line item

We quote the SN65HVD1471DR with the row, the moisture level and the marking stated per reel, and we hold the 3.3 V full duplex family together so a rate change does not become a sourcing project. Customers comparing this part against a 5 V transceiver can start from our CAN bus transceiver selection page, which also covers the RS-485 side of the same interface family.

When a bus segment is being extended or a node count is going up, the component lead time solutions page describes how we present the available rows and their date codes before a build schedule is fixed.