ISOUSB111DWR
Product Specifications
ISOUSB111DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISOUSB111DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISOUSB111DWR: an isolated USB 2.0 repeater in one body
The ISOUSB111DWR is a galvanically isolated USB 2.0 repeater that supports low speed at 1.5 Mbps and full speed at 12 Mbps. It sits between an upstream port and a downstream port and repeats the USB signalling across a silicon dioxide barrier, so a peripheral can be galvanically separated from a host without a hub chip, a separate isolator and an isolated supply on the peripheral side of the link.
The part handles the awkward parts of USB itself. It detects the connection and the speed automatically, reflects the pull ups and pull downs that a host or a device expects to see, supports the L1 sleep and L2 suspend states, and reverses the role of the upstream and downstream ports when a new connection appears on the other side. That last behaviour is what makes the part usable in On The Go and Type C dual role products.
Isolation is 5000 VRMS for one minute under UL 1577 with a working voltage of 1500 VRMS, and the common mode transient immunity is 100 kV per microsecond typical with 75 kV per microsecond minimum. The bus side runs from a VBUS range of 4.25 V to 5.5 V, an internal 3.3 V regulator supplies the transceiver, and the emissions performance is stated against CISPR 32 class B.
Key data for the ISOUSB111DWR
| Function | Isolated USB 2.0 repeater, transparent to the host and to the device |
| Speed | Low speed 1.5 Mbps and full speed 12 Mbps, with automatic speed and connection detection |
| Isolation | 5000 VRMS for 60 s per UL 1577, 1500 VRMS working voltage |
| Supply | VBUS 4.25 V to 5.5 V on the bus side, internal 3.3 V regulator for the transceiver |
| Immunity | CMTI 100 kV per microsecond typical and 75 kV per microsecond minimum |
| Power states | L1 sleep and L2 suspend supported, with automatic role reversal on reconnect |
| Emissions | Stated to meet CISPR 32 class B limits |
Body, packing and marking data
| Body | SOIC DW, 16 pins, wide body |
| Packing | 2000 pieces on a large reel |
| Finish | NIPDAU on the A row, moisture level 3 with a 168 hour floor life, 260 C peak |
| Marking | ISOUSB111 printed on the body |
| Temperature | Minus 40 C to plus 125 C |
What the repeater does not do
It does not provide power across the barrier. Each side needs its own supply, and the isolated side needs an isolated converter, which is where a part like the ISOW series or a small flyback earns its place. A board that expects the repeater to pass VBUS through the barrier will not get a working port, because the barrier is a data barrier and the bus power is separate.
It also does not negotiate. The repeater passes the signalling through, and the host and device still run their own enumeration, including any descriptor request that the application depends on. That is what makes it transparent, and it is also why a marginal cable or a device that draws more than the port can supply still fails, with the repeater faithfully passing the failure along. Debug the port with the repeater in place rather than assuming the isolation is the cause, and check the cable, the port current budget and the device descriptor before the part is changed.
Where an isolated USB port is needed
Medical instruments use an isolated USB port so a patient connected device can talk to a PC without carrying the PC ground into the measurement. Test and measurement equipment uses the same part to break a ground loop between an instrument and a laptop, and industrial equipment uses it where a service laptop would otherwise tie the cabinet ground to the bench.
Our medical device component sourcing page covers the documentation for a patient connected port, and the how to verify a drop in replacement page covers the bench checks when a board moves from a hub plus isolator arrangement to this repeater.
Questions we get on this code
Buyers ask whether high speed USB at 480 Mbps is supported. It is not. This part covers low speed and full speed only, and a high speed link needs a different device. A camera or a mass storage port on a medical instrument usually needs high speed, so check the device descriptor before the part is chosen.
The second question is about role reversal. It is automatic and it happens after a disconnect, which is fine for a dual role port and confusing for a fixed host. If the product is a fixed host, confirm that the downstream port is where the device is plugged and that no reconnect happens on the upstream side during normal use, because a reversal in the middle of a session will drop the link and force a fresh enumeration.