ISO808TR
Product Specifications
ISO808TR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO808TR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO808TR: eight isolated high side channels in one PowerSO-36
ISO808TR is the tape and reel order code of the ISO808, an eight channel galvanically isolated high side driver from STMicroelectronics built for inductive loads in factory automation. Each channel is a solid state relay with its own current limit and its own thermal shutdown, and the whole device carries two galvanically isolated voltage domains: VCC and ground on the process side where the load sits, VDD and ground on the logic side where the controller sits. The two sides talk through an isolation barrier and an ST proprietary protocol, and nothing in the signal path crosses that barrier as a copper connection.
The part is the parallel interface member of the family. A host drives eight input pins, a common output enable and a reset line, and reads one open drain fault output. The SPI member with the same eight channels and a status register is a different order code, and a board wired for the parallel part cannot be reworked to the serial one without changing the pattern.
Everything below is taken from DS14169 Rev 6, July 2025: the process side and logic side ranges, the on resistance, the current limit, the watchdog window, the thermal resistances of the two packages and the isolation ratings that the safety file has to quote.
What the order code sits on
| Function | eight channel galvanically isolated high side driver, parallel interface |
| Process side supply | 9.2 V to 36 V on VCC, 45 V absolute maximum |
| Logic side supply | 2.75 V to 5.5 V on VDD, 3.3 V and 5 V compatible inputs |
| On resistance | 0.125 ohm typical per channel |
| Channel current | under 0.7 A on ISO808, under 1 A on ISO808-1 |
| Current limit | 0.7 A minimum on this grade, active limitation per channel |
| Clamp on VCC | 47 V minimum, 52 V typical, 57 V maximum |
| Demagnetisation | VCC minus 54 V typical, for fast turn off of inductive loads |
| Isolation | 2500 Vrms withstand on PowerSO-36, 3000 Vrms on TFQFPN32 |
| Clearance and creepage | 2.6 mm on PowerSO-36, 3.3 mm on TFQFPN32 |
| Thermal resistance | 0.8 degrees per watt junction to case, 16.9 junction to ambient on PowerSO-36 |
| Dissipation ceiling | 3.8 W at 85 degrees ambient on PowerSO-36 with the junction below 150 degrees |
| Storage temperature | minus 40 to plus 150 degrees |
| ESD | 2000 V human body model |
| Standards | UL1577 and UL508 certified, safety limits per IEC 60747-17 |
Two supplies, two under voltage lockouts
The device runs from two rails that are not allowed to come up in any particular order, so each side has its own under voltage lockout with hysteresis. On the process side the turn on threshold is between 8.4 V and 9.2 V and the turn off threshold is between 7.7 V and 8.1 V, which gives about 150 mV of hysteresis at a 36 V rail. On the logic side the window is tighter: turn on between 2.55 V and 2.75 V, turn off between 2.45 V and 2.65 V, hysteresis between 40 mV and 100 mV.
The consequence for a 24 V system is that the driver keeps working down to a supply that a 24 V rail only reaches during a deep dip, and stops cleanly below that rather than driving the gates with a gate voltage that is too low to keep the channel in saturation. A 24 V industrial rail with a wide tolerance and a transient requirement is the case this device was written for, and the 45 V absolute maximum on the supply pin gives room for the clamp to act before the process stage is damaged.
The logic side at 2.75 V minimum is what allows a 3.3 V microcontroller to drive the inputs directly. The input thresholds are specified against the VDD rail rather than against a fixed voltage, so a board that runs the logic side at 3.3 V and a board that runs it at 5 V both see the same relative margins, and a mixed system with a 3.3 V host and a 5 V sensor bus does not need level shifting between them.
What the watchdog protects and what it does not
The two halves of the device are supplied separately and communicate over the barrier, and the watchdog exists for the case where the logic side loses its supply. The logic stage sends a refresh to the process stage at about 15 kHz, and if the process stage does not receive an update within the watchdog window, which is 272 to 400 microseconds with 320 typical, all outputs are turned off until a new update arrives. A failure of the logic rail therefore leaves the loads de-energised rather than latched in whatever state they were in.
The data sheet is explicit that this does not protect against a host controller that has frozen. The refresh signal counts as a valid update, so a microcontroller that stops writing new commands but keeps the interface alive will keep the outputs in their last commanded state. A system that needs to detect a frozen host has to do so on the host side, with its own watchdog, and treat the driver as a device that will hold the last command indefinitely.
Thermal behaviour with eight channels in one body
Eight channels sharing one die means the thermal path is shared even though the protection is not. Each channel has its own junction temperature sensor and turns off when it crosses the shutdown threshold, restarting when it falls below the restart threshold, and there is a separate case temperature sensor that turns off the overloaded channels when the case crosses its own limit while leaving the healthy channels running. That split is what keeps one shorted output from taking the other seven down during a fault.
The numbers to size a heatsink or a copper area against are the thermal resistances: 0.8 degrees per watt junction to case and 16.9 junction to ambient for the PowerSO-36, which with an 85 degree ambient and a 150 degree junction allows 3.8 W in the package. At 0.125 ohm and 0.7 A per channel the conduction loss is about 61 mW per channel, so eight channels fully on dissipate under half a watt and the thermal budget is dominated by switching and by the load current during a fault rather than by normal operation.
The 0.7 A current limit is the number that decides the load, not the 0.7 A rating alone. A solenoid that draws 0.5 A steady and 1.4 A inrush will hit the limit on every actuation, and the channel will regulate the current at 0.7 A for as long as the inrush lasts, with the excess voltage dropped across the die. The data sheet gives the single pulse avalanche energy and the thermal impedance, and the practical rule is to size the load so the inrush stays inside the limit or to accept that the channel will thermally cycle on every cycle of the load.
Packages, carriers and the ordering table
| PowerSO-36 | through hole style power package, 2.6 mm clearance, 0.8 degrees per watt junction to case |
| TFQFPN32 | surface mount, 3.3 mm clearance, 3000 Vrms isolation, 1 degree per watt junction to case |
| ISO808TR | PowerSO-36 order code, the tape and reel row of the table |
| ISO808TR-1 | same package, the 1 A per channel grade |
| ISO808QTR | TFQFPN32 order code, tape and reel |
| ISO808QTR-1 | TFQFPN32, 1 A per channel grade |
| Carrier | the PDF extract interleaves the tube and tape and reel columns, so the carrier is confirmed on the purchase order |
| Document | DS14169 Rev 6, July 2025 |
The ordering table in the data sheet is printed as four columns and the text extraction interleaves them, which is why the carrier line above reads as a caution rather than as a quantity. What is not ambiguous is the split between the two packages: the PowerSO-36 body carries the higher clearance and the lower thermal resistance, and the TFQFPN32 body carries the higher isolation rating and a smaller footprint. A board that has to pass a 3000 Vrms hipot at the barrier wants the QFN part, and a board that has to dissipate a fault current for a measurable time wants the PowerSO part.
Where the part belongs
Programmable logic controllers, industrial PC input and output cards, numerical control machines and drivers for resistive, capacitive and inductive loads are the applications the vendor lists. The common requirement is a bank of outputs that a controller has to switch while the field side sits at a different ground potential, and the alternative to an isolated driver is eight optocouplers, eight discrete switches and a current limit circuit per channel, which is more than twice the board area and a much longer bill of materials.
For a buyer the interesting question is usually whether the parallel part or the serial part is the right one. The parallel part needs eight microcontroller pins plus an enable and a reset, and it gives back one fault line; the serial part needs four pins and gives back per channel diagnostics. A board with a small controller and a fixed load bank is the parallel case, and the workflow on our power management cross reference page lists what to compare when a customer is choosing between them, including the fault reporting a test fixture needs. When the chosen part is short, the component lead time solutions page covers the options short of a board change.
Questions buyers ask before a first order
Does the part work on a 12 V field supply? Yes. The process side starts at 9.2 V, so a 12 V rail is inside the range with the under voltage lockout clearing at about 8.8 V.
What happens if the logic supply disappears? The watchdog turns all outputs off within 320 microseconds typical and holds them off until an update arrives, so the loads are de-energised rather than latched.
Can two channels be paralleled for a higher current? The data sheet does not publish a paralleling specification for this family, and the current limit is per channel, so a load above 0.7 A belongs on the 1 A grade rather than on two channels in parallel.
Is the isolation rating the same on both packages? No. The PowerSO-36 is rated 2500 Vrms and the TFQFPN32 is rated 3000 Vrms, and the creepage differs with it, so the package choice follows the safety requirement rather than the footprint.