Contact Us

ISO7842FDWWR

Brand: Texas Instruments
Texas Instruments ISO7842FDWWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO7842FDWWR — Power Management & Signal Chain | Superb Automation

ISO7842FDWWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO7842FDWWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO7842FDWWR: The 8000 VPK Reinforced Quad in the Extra Wide Body

ISO7842FDWWR is a reinforced four channel digital isolator with two channels each way in a SOIC (DWW) body of 16 pins. It reaches 8000 VPK of reinforced isolation and 5700 VRMS for one minute by moving to a body that is 17.25 mm wide, with 14.5 mm of clearance, two channels forward and two back at 100 Mbps, and the F suffix driving every output low when the input side dies.

Order code and package

Ordering stringISO7842FDWWR
PackageSOIC, 16 pins, DWW extra wide body, 10.30 mm by 17.25 mm nominal
Carrier1000 pieces on a large reel
Tube siblingISO7842FDWW at 45 pieces in a tube, same die
Narrow body siblingISO7842FDWR in the DW body at 2000 pieces on a reel, 8 mm clearance and a lower barrier
Moisture levelLevel 2, 260 C peak reflow, one year floor life
Temperature rangeMinus 55 to plus 125 degrees Celsius
Part markingISO7842F
Channel directionTwo channels forward, two reverse
Default outputLow, set by the F suffix

Electrical parameters that decide the application

Signaling rate100 Mbps
Propagation delay11 ns typical at 5 V, with the maximum printed per rail in the switching tables
Supply current per channel1.7 mA typical at 1 Mbps
Supply range2.25 to 5.5 V, with level translation across the same range
Isolation rating5700 VRMS for one minute per UL 1577, tested at 1.2 times for one second on every unit
Maximum repetitive peak voltage2828 VPK in the DWW body against 2121 VPK in the DW body
Maximum working voltage2000 VRMS in the DWW body against 1500 VRMS in the DW body
Maximum transient voltage8000 VPK
Maximum impulse voltage9800 VPK
Maximum surge voltage12800 VPK, 1.2 by 50 microsecond waveform
External clearanceAbove 14.5 mm in the DWW body, 15.0 mm typical, against above 8 mm in the DW body
External creepageAbove 14.5 mm in the DWW body, 15.0 mm typical
Distance through insulationAbove 21 micrometres
Tracking indexAbove 600 V, material group I
Barrier capacitance2 pF from input to output
Common mode transient immunityPlus or minus 100 kV per microsecond minimum, the leading figure in this family
Barrier lifeAbove 40 years at the rated working voltage
Enable pinsOne per output, driving the output to high impedance
Climatic category55/125/21, pollution degree 2

Family variants and how they differ

ISO7842DWWRThe same extra wide body with the high default output
ISO7842FDWRThe wide body version at 2000 pieces on a reel, 8 mm clearance, same 8000 VPK transient but a lower working voltage
ISO7842FDWWThis die in a 45 piece tube
ISO7742FDWRThe 100 Mbps quad at 5000 VRMS when the barrier does not need the extra wide body
ISO6741FDWRA 50 Mbps quad in the wide body at lower cost
ISO6731FDWRA 50 Mbps triple when only three lines cross the barrier

Points to check before this part goes on a BOM

The extra wide body buys working voltage, not transient voltage. Both bodies are printed at 8000 VPK transient and 9800 VPK impulse, and the difference appears in the repetitive peak figure, 2828 VPK against 2121 VPK, and in the working voltage, 2000 VRMS against 1500 VRMS. A specification written around surge alone does not need the wider body.

Clearance in the DWW body is above 14.5 mm with 15.0 mm typical, which is roughly twice the wide body. On a board, that distance has to survive the mounting pads and any coating, so the pad geometry under the part is part of the isolation review rather than a mechanical detail.

The temperature range starts at minus 55 degrees, not minus 40. That is unusually wide for a digital isolator and it is one of the reasons the part appears in rail and defence bills of material, where the ambient requirement is often written to minus 55.

The enable pins put the output into high impedance rather than into the default level. In a multi-controller arrangement that is what allows two isolators to share one bus, but it also means the bus has to be pulled to a defined state by something else while both are disabled.

The 1000 piece reel is the smallest in this family. The extra wide body is not offered in a 2000 piece reel, so a low volume build takes the 45 piece tube and the packing cost has to be carried in the quote.

Where the wide body is worth its board area

Rail traction, grid protection and medical equipment all write their isolation requirement against a working voltage rather than against a surge, because the barrier sits across a supply that is present continuously. In those applications the 2000 VRMS working figure of the DWW body is the number being certified, and the wide body earns its area back on the certificate.

A second group of boards uses the part purely for clearance. When the mechanical envelope allows a 17.25 mm body and the safety review asks for more than 14 mm of clearance, the wider part avoids routing slots and keep-out work that would otherwise cost more than the component.

The enable pins and the fail-safe state

Two channels run each way in this part, and every output has its own enable. A controller that wants to park the bus drives the enable and lets the output float, which is different from letting the input side lose power, where the output goes to the default low after the fail-safe delay.

Both states are useful and they are not the same. Confusing them is a common source of a bus that behaves correctly on the bench and locks up in the field, because the pull resistors were sized for the floating state and not for the driven one.

How the two bodies compare on paper

Both bodies carry the same 100 Mbps channel, the same 2.25 to 5.5 V supply range and the same 40 year barrier life projection. The extra width is spent entirely on distance, which lifts the clearance from above 8 mm to above 14.5 mm and the working voltage from 1500 VRMS to 2000 VRMS.

That means a board built around the wide body for clearance reasons still gets the same timing and the same drive strength. The change is mechanical and documentary rather than electrical.

Stock and packing

The extra wide body ships 1000 pieces on a reel and 45 in a tube, and there is no 2000 piece reel. For a programme that builds a few hundred boards a quarter, the tube is the practical carrier and the packing cost per unit is higher than on the wide body.

Holding both bodies on the shelf is common, because a single programme often has one board that needs the wider barrier and several that do not. Marking the reels clearly matters, since the two parts differ by one letter in the ordering string.

Where this order code fits

It is chosen where a reinforced barrier has to hold a high working voltage continuously and the mechanical envelope allows the extra wide body, most often in rail, grid protection and medical equipment rather than in a compact industrial module. Teams comparing it with a neighbouring part start from our Strategic Sourcing page, and teams replacing a part that has gone end of life start from the Supplier Quality Audit page.

Questions buyers ask

Can the wide body part drop into a board routed for the DW body? No. The DWW body is 17.25 mm long against 10.30 mm, and the pin pitch is the same but the span is not. It needs its own footprint and its own clearance review.

What does the extra width actually buy? More than 14.5 mm of clearance and creepage against above 8 mm, a 2828 VPK repetitive peak rating against 2121 VPK, and a 2000 VRMS working voltage against 1500 VRMS. The transient and impulse ratings are the same in both bodies.

Why is the supply range 2.25 to 5.5 V rather than 3.3 to 5 V? The barrier is built to translate across that full range, so a 2.5 V FPGA can talk to a 5 V driver through one part. The output drive and the propagation delay do change with the rail, so the switching table has to be read at the rail in use.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.