ISO6760QDWRQ1
Product Specifications
ISO6760QDWRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO6760QDWRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO6760QDWRQ1: six isolated channels facing one way
The ISO6760QDWRQ1 is the six channel member of the ISO676x group, and all six channels on this part number run in the forward direction. One side drives, the other side receives, and every channel crosses the same silicon dioxide barrier. Boards that need a wide parallel bus, a row of gate signals or a bundle of digital inputs crossing a safety boundary use this shape because nothing has to be turned around mid bus.
Each channel is a logic input, a capacitive barrier and a logic output buffer. The barrier is rated to 5000 VRMS for one minute under UL 1577 and certified to DIN EN IEC 60747-17, with 1500 VRMS of working voltage and a 10 kV surge capability. With no input power or no input signal on the F version the output falls low, and on the plain version it stays high. The plain code on this page therefore holds a defined high state when the field side goes dark.
Data rate reaches 50 Mbps, and the propagation delay is 11 ns typical and 18 ns maximum at a 5 V rail. Common mode transient immunity is 150 kV per microsecond typical, which is the figure that decides whether a motor drive edge or a switching node couples through the barrier and corrupts a sample. Supply current sits at 1.6 mA per channel typical at 1 Mbps, so six channels cost about a tenth of what six optocouplers would draw.
Key data for the ISO6760QDWRQ1
| Channels | Six, all six in the forward direction, one input buffer and one output buffer per channel |
| Data rate | 50 Mbps maximum specified |
| Isolation | 5000 VRMS for 60 s per UL 1577, 4242 VPK per VDE 0884-17, 1500 VRMS working voltage, 10 kV surge |
| Supply | Side one 1.71 V to 1.89 V and 2.25 V to 5.5 V, side two the same, so 1.71 V to 5.5 V translation is available in either direction |
| Timing | Propagation delay 11 ns typical and 18 ns maximum at 5 V, pulse width distortion 7 ns maximum |
| Immunity | CMTI 150 kV per microsecond typical, system level ESD, EFT and surge immunity stated by the vendor |
| Current | 1.6 mA per channel typical at 1 Mbps, 5.7 mA maximum for the whole side at DC input |
Body, packing and marking data
| Body | SOIC DW, 16 pins, 10.30 mm by 7.50 mm, the wide body that carries the 5000 VRMS barrier |
| Packing | 2000 pieces on a 330 mm reel, tape width 16.4 mm, on the published rows of this family |
| Finish | NIPDAU, moisture level 2, 260 C peak, one year floor life |
| Temperature | Minus 40 C to plus 125 C on every published row of the family |
Order code note before you place the string on a purchase order
The catalogue string on this page carries a Q1 suffix, and the orderable addendum of the industrial document does not print that suffix. The rows it does publish are ISO6760DWR and ISO6760FDWR, both at 2000 pieces on a large reel, both NIPDAU at moisture level 2, both minus 40 C to plus 125 C. The tape and reel table at the back of the same document carries a Q1 column, which is where the letter comes from, but a column in a packing table is not an orderable row.
That distinction matters at goods inwards. If the purchase order names the Q1 string and the carton arrives marked ISO6760DWR, an inspector who only compares strings will reject a correct part. Either confirm the automotive release with the vendor before the order is placed, or write the industrial string on the order and keep the qualification question separate. The automotive version, where it exists, is released under its own document with its own temperature grade.
Where six forward channels earn their place
A three phase inverter needs six gate signals crossing from the controller to the power stage. Six channels in one body keep the skew tight, keep the bill of materials short and keep the board area down. The same count covers a parallel ADC interface, a bank of relay drivers or a set of digital inputs from a field connector, which is why the part turns up in motor control, grid equipment, factory automation and building automation at the same time.
Medical monitors use the same barrier for a different reason: patient connected circuits have to stay separated from mains referenced circuitry, and the 5000 VRMS rating with a 1500 VRMS working voltage covers the isolation requirement in one component. Our medical device component sourcing page covers the paperwork that goes with that decision, and the pin to pin cross reference page is the place to start when a board is moving from an optocoupler row to this part.
Questions we get on this code
The first question is always the difference between the isolation rating and the working voltage. The 5000 VRMS figure is a one minute withstand test at production and qualification. The 1500 VRMS figure is what the part can hold continuously for the life of the equipment, and that is the number a safety file has to use. A board that leans on the withstand number for continuous stress will not pass a review.
The second question is the default state. If the output must read low when the field side loses power, the F version is the correct order code. If it must read high, the plain version is. Mixing the two on one board is a common source of a fault that only appears when a connector is unplugged. Ask for the F suffix in writing, and check the marking on the first article against the row in the packing table.