The ISO6720FBQDRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO6720FBQDRQ1: The Automotive Dual With Both Channels Forward and a Low Default

ISO6720FBQDRQ1 is an automotive qualified dual-channel digital isolator in a SOIC (D-8) body of 8 pins. It is the automotive string of the two channel forward isolator with the low default, built on the same 50 Mbps channel as the industrial part, and the document that carries the electrical tables prints no automotive row at all.

Order code and package

Ordering stringISO6720FBQDRQ1
FamilyISO672x-Q1, the automotive option named in the industrial document
Package implied by the suffixSOIC, 8 pins, D body, 4.90 mm by 3.91 mm nominal
Reel and packingNot printed in SLLSFJ0F, confirm on the automotive addendum and on the reel label
Industrial reference rowISO6720FBDR at 3000 pieces on a large reel, level 2, marking 6720FB
Temperature rangeMinus 40 to plus 125 degrees on the industrial rows of the same silicon
Channel directionTwo channels, both from side 1 to side 2
Default outputLow, set by the F suffix
Isolation classReinforced, which is why the automotive family is documented separately

Electrical parameters that decide the application

Signaling rate50 Mbps on the industrial rows of the same channel
Isolation ratingThe automotive string is named as the reinforced option, the industrial rows print 3000 VRMS
Maximum repetitive peak voltage637 VPK on the industrial rows
Maximum working voltage450 VRMS and 637 VDC on the industrial rows
Maximum transient voltage4242 VPK on the industrial rows
Maximum impulse voltage5000 VPK on the industrial rows
Maximum surge voltage6500 VPK on the industrial rows
Common mode transient immunity150 kV per microsecond typical, 100 kV per microsecond minimum
Supply range1.71 to 1.89 V, or 2.25 to 5.5 V, per side
Level translation1.71 V to 5.5 V
Supply current per channel1.8 mA typical at 1 Mbps
Propagation delay11 ns typical, 18 ns maximum at 5 V
Pulse width distortion0.2 ns typical, 7 ns maximum at 5 V
External clearanceAbove 4 mm on the industrial body
ESD across the barrierPlus or minus 8 kV IEC 61000-4-2 contact discharge
Enable pinNone in the eight pin body
BarrierDouble capacitive silicon dioxide

Family variants and how they differ

ISO6720FBDRThe industrial string of the same channel split and the same low default
ISO6720BDRThe industrial string with the high default
ISO6721FBQDRQ1The automotive one-each-way member when a line has to come back
ISO6721FBDRThe industrial one-each-way part at the same body and reel
ISO7741-Q1A quad automotive isolator at 100 Mbps when two channels are not enough
ISO6731FDWRAn industrial triple at 50 Mbps as a cost reference

Points to check before this part goes on a BOM

The automotive rows are not printed in SLLSFJ0F. The document covers ISO6720, ISO6721 and ISO6721R and its addendum lists the industrial strings only, so the reel quantity, moisture level and marking for this ordering string have to be read from the Q1 addendum or from the label rather than assumed from the industrial row.

The industrial and automotive strings share the silicon, so the rate, current and delay figures carry across. The qualification, the temperature grade and the barrier class do not, and the reinforced class is the reason this string exists separately.

Both channels drive forward. A vehicle bus line that has to come back needs ISO6721FBQDRQ1, which is the same body with one channel in each direction, and mixing the two up on a bill of material is the kind of error that only shows up at first power up.

The low default matters more in a vehicle than on a bench. A gate driver that fires while the controller rail is still rising is a hardware fault, and the F suffix is what keeps that output low until the input side is fully powered and driving.

A 4 mm clearance in an eight pin body is a body property, not a grade property. The automotive qualification does not increase the distance, so a board that has to meet a larger clearance needs the wide body family regardless of the qualification.

A vehicle board that needs two forward channels and a low default has very few alternatives in this body size, and that is why the string is held on approved vendor lists even when the industrial part is already qualified for the same socket.

The channel count is the constraint to check first. Two forward channels cannot carry a bus that answers back, and the automotive one-each-way string is a different ordering code rather than a configuration of this one.

Why the automotive string is quoted as a separate line

A vehicle programme is qualified against the automotive document, and the paperwork has to name the ordering string that was tested. Quoting the industrial part as an equivalent is not accepted even though the silicon is the same, because the qualification evidence is attached to the string.

In practice the difference shows up in the purchase order and in the receiving inspection sheet, not in the board file. That is why the string is worth carrying on the approved vendor list as its own line rather than as an alternate of the industrial part.

What to confirm before a first order

Three things are not in the industrial document: the reel quantity, the moisture level and the marking. All three sit on the label and on the automotive addendum, and all three matter for a production line, because a level 3 part with a 168 hour floor life is handled differently from a level 2 part with a one year floor life.

The marking is the other one. Automotive markings often differ from the industrial string by a character or a suffix, and an inspection sheet written from the industrial row will flag every reel as non conforming.

What the qualification actually changes

The qualification covers the temperature grade, the test flow and the documentation, and it is attached to the ordering string. The silicon, the channel count and the barrier structure stay the same as the industrial part, which is why the electrical figures carry across in the tables.

For a programme that has to show evidence, the string on the purchase order has to match the string on the qualification report. That is a documentary requirement and it is the main reason the automotive line exists separately.

Where the eight pin body runs out of room

The body carries two channels and no enable pin. An application that needs a third line, or a way to park a line during power up, has to move to the wide body, and that move costs board area and a clearance review rather than only a component change.

That is worth deciding early. Moving from a two channel to a three channel part late in a programme usually means a board revision, and the automotive qualification evidence then has to cover the new board as well.

Where this order code fits

It is chosen where two digital lines cross one barrier in one direction on a vehicle board and the outputs have to stay low until the controller side is fully powered. Teams comparing it with a neighbouring part start from our OEM Procurement page, and teams replacing a part that has gone end of life start from the Supplier Onboarding Checklist page.

Questions buyers ask

Is this the same part as ISO6720FBDR? It is the same silicon and the same channel split. The automotive string carries its own qualification, temperature grade and barrier class, and its packing is not printed in the industrial document.

Can it be used for a line that has to come back? No. Both channels face forward. The one-each-way automotive part is ISO6721FBQDRQ1, and it uses the same eight pin body.

What should be checked on the first delivery? The reel quantity, the moisture level and the marking, because none of the three is printed in the document that carries the electrical tables. The marking in particular often differs from the industrial string.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Date Code Management page sets out the checks that keep a substitute from failing on the bench.