Contact Us

ISO6521FDR

Brand: Texas Instruments
Texas Instruments ISO6521FDR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO6521FDR — Power Management & Signal Chain | Superb Automation

ISO6521FDR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO6521FDR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO6521FDR: the same two way link with outputs that fail low

The ISO6521FDR is the F variant of the dual channel functional isolator, with one channel in each direction and a default output that goes low when the input side loses power or its signal. The barrier is the same double capacitive silicon dioxide structure, rated for functional isolation at 450 Vrms and 637 Vdc of working voltage with a 2000 Vrms transient for 60 seconds, and each channel carries 50 Mbps with 11 ns typical propagation delay at 3.3 V.

The difference from the plain part is a single behaviour, and it is the behaviour that decides safe state in a fault. A gate signal, an enable line or a chip select that must not be asserted when the controller disappears needs a low default. A part that drives high in the same event can command a power stage on, which is the failure mode that a safety review looks for first.

Key data for the ISO6521FDR

ChannelsTwo channels, one forward and one reverse, in an eight pin body
DefaultOutput low when the input side is unpowered or the input signal is lost
Rate50 Mbps per channel, 11 ns typical propagation delay at 3.3 V
IsolationFunctional class: 450 Vrms and 637 Vdc working, 2000 Vrms and 2828 Vdc transient for 60 s
Supplies1.71 V to 1.89 V and 2.25 V to 5.5 V rails, translation across 1.71 V to 5.5 V
PowerAbout 1.8 mA per channel at 1 Mbps at 3.3 V, 150 kV per microsecond typical CMTI

Body, marking and reel data

BodySOIC D, 8 pins, 4.9 mm by 6.0 mm, with the leadless VSON option at 3.0 mm by 2.0 mm
Reel3000 pieces on a large reel on both body options
Marking6521F on the body
HandlingMoisture level 2, 260 C peak, one year floor life
TemperatureMinus 40 C to 125 C

What the F suffix changes in a real product

Consider a driver board that holds a power switch closed through an isolated enable line. If the controller card is pulled, the isolator input disappears. A default high part keeps the enable asserted and the switch stays closed with nobody in command. The F part releases the line, the switch opens, and the product returns to a state that a technician can work on safely. That single difference is why the F rows exist and why the two rows are never interchangeable on a bill of materials.

The second scenario is a fault output. A return channel that reports a fault should read as no fault when the remote side is dead, or as fault. The choice depends on whether the system can tolerate a spurious stop or would rather stop on doubt. Both answers are defensible; the part number has to match the one the safety case assumes.

Ordering and verification notes

The first check is the marking. This row prints 6521F and the plain row prints 6521, so a visual inspection at goods in will separate them, but only if the inspection sheet lists both. The second is the reel: 3000 pieces on a large reel is the only published packing, so a smaller build takes a partial reel or a distributor cut.

The third is the barrier class. Functional isolation at 450 Vrms is not a safety barrier, and a product that relies on the barrier for protection needs a different family. The fourth is the supply on each side: the 1.71 V to 1.89 V window and the 2.25 V to 5.5 V window are not symmetric, and a rail that sits at 2.0 V satisfies neither.

Safe state, marking and the goods in check

This row is bought when the safe state has to be low, and the quotation says so explicitly because the marking on the body is the only visible difference from the plain part. An inspection sheet that lists 6521 will pass a 6521F reel without noticing, and a board that relies on the low default will then hold a power stage on during a fault. We print both strings on the incoming check and confirm the suffix on the reel label.

The second point is the barrier class. Functional isolation at 450 Vrms is not a safety barrier, and a product that relies on the isolator for protection needs a different family. The third is the rail window: one side takes 1.71 V to 1.89 V and the other 2.25 V to 5.5 V, so a 2.0 V rail sits outside both and the link will not run.

Where the enable line belongs to a power stage and the safe state has to be documented, our note on component verification at goods in is on our incoming inspection plan page. Where the isolator is one line of a larger kit that has to arrive together, the service is described on our kitting service page.