ISO1410DWR
Product Specifications
ISO1410DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1410DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1410DWR: 5 kVRMS isolated RS-485 and RS-422 transceiver, 500 kbps, wide body SOIC
ISO1410DWR is a galvanically isolated half bridge between a logic side and an RS-485 bus, with the isolation barrier and the bus protection inside one body in a SOIC (DW) body of 16 pins. It carries 500 kbps across a 5 kVRMS barrier, protects the bus pins against 30 kV of human body discharge and 16 kV of contact discharge, and holds 256 nodes on one bus with an eighth unit load receiver.
Order code and package
| Ordering string | ISO1410DWR, DW package, 16-pin wide body SOIC, tape and reel |
| Family members | ISO141x at 500 kbps, ISO143x at 12 Mbps, ISO145x at 50 Mbps, in basic and reinforced options |
| Package | 16-pin wide body SOIC, 10.3 mm body width for the creepage the barrier needs |
| Ambient range | -40 C to 125 C |
| Isolation ratings | 5000 VRMS for one minute per UL 1577, 7071 VPK transient and 1500 VPK working voltage |
| Supplies | VCC1 from 1.71 V to 5.5 V on the logic side, VCC2 from 3 V to 5.5 V on the bus side |
Electrical parameters that decide the application
| Data rate | 500 kbps for the ISO141x members |
| Bus standard | TIA/EIA-485-A, and PROFIBUS compatible at a 5 V bus supply |
| Bus protection | 30 kV HBM, 16 kV IEC 61000-4-2 contact, 4 kV IEC 61000-4-4 fast transient |
| Common mode transient immunity | 100 kV per microsecond typical |
| Unit load | One eighth, up to 256 nodes on one bus |
| Fail safe | Receiver output defined for bus open, bus short and idle bus |
| Certifications | VDE 0884-17, UL 1577, IEC 62368-1, IEC 60601-1, IEC 61010-1, plus CQC, TUV and CSA |
Points to check before this part goes on a BOM
The logic side runs from 1.71 V, which is the detail that makes this part usable next to a modern processor. A 1.8 V UART cannot drive a 5 V transceiver directly, and a level shifter in front of an isolator adds a component and a propagation delay. Here the logic side is powered from the processor rail and the bus side from the field rail, and the two can be any combination inside the ranges.
The 500 kbps member is not a slow version of the fast one, it is the low emission version. A slower edge rate radiates less, which is why the 500 kbps parts are the ones specified for PROFIBUS at 5 V and why they are chosen in motor drive cabinets where a 12 Mbps part would need shielding. If the protocol needs 12 Mbps the ISO143x member is the same body and pinout, and the board can be re-populated.
The 16 kV contact discharge rating is a system level number only when the bus is laid out as the data sheet shows. The protection clamps are inside the device, and their effect depends on the return path from the connector to the bus side ground being short and wide. A board that runs the pair across a split in the ground plane loses most of the rating, and the failure appears as a transceiver that dies in the field but never on the bench.
The 100 kV per microsecond common mode transient immunity is what keeps a node alive when the ground potential of two cabinets jumps. At that rate a 1 kV step arrives in 10 ns, and a transceiver without the barrier sees it as a data edge. This is the reason an isolated part is used even when the protocol would work with a non isolated one: the isolation is for the ground difference, not for the data.
Failsafe output state is a protocol requirement in RS-485, not a convenience. When no driver is enabled the bus floats, and a receiver without failsafe outputs random data that the UART reads as a stream of start bits. The data sheet guarantees a defined state for open, shorted and idle bus, which is what allows a multi-drop network to keep its framing during the gaps between messages.
The eighth unit load receiver is what allows 256 nodes. A standard unit load limits a bus to 32 nodes, and the arithmetic is set by the driver current and the input current of each receiver. In a retrofit where an existing network already has 40 nodes, this part is the way to add a segment without changing the driver or the termination, and the termination resistors stay at the same values.
Termination is unchanged by the isolation and is still the part people get wrong. An RS-485 segment needs 120 ohm at each physical end and nothing in the middle, and the isolated node counts as one node on the segment. The failsafe receiver covers the idle bus, so external bias resistors are only needed when the network is long enough that the leakage of 256 receivers pulls the differential voltage below the threshold, which at an eighth unit load per node is a much smaller effect than the old 32 node buses had.
Where this order code fits
It is used in grid equipment, solar inverters, factory automation, motor drives, HVAC controllers and building automation, where an RS-485 segment crosses between cabinets or between a logic board and a field wiring terminal block. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Defense Grade Components page.
Questions buyers ask
Can the logic side run at 1.8 V and the bus side at 5 V? Yes. VCC1 accepts 1.71 V to 5.5 V and VCC2 accepts 3 V to 5.5 V, so the two sides are independent and the part also translates levels.
Does it need external protection on the bus? The bus pins carry the ESD and fast transient ratings internally, so the extra components are only needed for surge levels above the specified IEC tests.
What is the difference from the 12 Mbps member? Data rate and edge rate. The 500 kbps part is quieter and is the one specified for PROFIBUS, the 12 Mbps part is for faster protocols, and both share the package and pinout.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.