ISO1410BDWR
Product Specifications
ISO1410BDWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1410BDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1410BDWR: The 500 kbps Half-Duplex Member of the 5 kVRMS Isolated RS-485 Family
ISO1410BDWR is an isolated half-duplex RS-485 and RS-422 transceiver with a basic barrier in a SOIC (DW) body of 16 pins. It is the slowest member of the ISO14xx family at 500 kbps, built for long cable runs where a low edge rate matters more than throughput, and the B suffix is the basic isolation option.
Order code and package
| Ordering string | ISO1410BDWR |
| Package | SOIC, 16 pins, DW wide body, 10.30 mm by 10.30 mm nominal |
| Isolation option | B suffix, basic isolation, 6000 VPK surge against 10000 VPK on the reinforced rows |
| Carrier | The family addendum is offset row by row, the pattern is a 40 piece tube and a 2000 piece reel |
| Temperature range | Minus 40 to plus 125 degrees Celsius |
| Duplex | Half duplex, DE and RE control on the logic side |
| Logic side supply | 1.71 V to 5.5 V |
| Bus side supply | 3 V to 5.5 V |
| Pin compatibility | Same pin map as most isolated RS-485 transceivers in a wide body |
Electrical parameters that decide the application
| Signaling rate | 500 kbps |
| Bus standard | TIA/EIA-485-A, PROFIBUS compatible at a 5 V bus supply |
| Bus loading | One eighth unit load, up to 256 nodes |
| Fail-safe | Receiver output high on bus open, short and idle |
| Common mode transient immunity | 100 kV per microsecond typical |
| ESD on the bus pins | Plus or minus 30 kV human body model |
| IEC ESD | Plus or minus 16 kV contact discharge per IEC 61000-4-2 |
| Fast transient | Plus or minus 4 kV per IEC 61000-4-4 |
| Isolation, UL | 5000 VRMS for one minute |
| Transient isolation | 7071 VPK |
| Working voltage | 1500 VPK repetitive peak |
| Surge, basic option | 6000 VPK per VDE against 10000 VPK on the reinforced rows |
| Power up behaviour | Glitch free on both rails, safe for hot plug in |
| Body | Wide body SOIC, the reason the clearance suits mains-referenced buses |
Family variants and how they differ
| ISO1410 | Same 500 kbps half duplex device with the reinforced barrier |
| ISO1412B | Full duplex at 500 kbps with the basic barrier |
| ISO1430B | Half duplex at 12 Mbps, the middle rate of the family |
| ISO1432B | Full duplex at 12 Mbps |
| ISO1450B | Half duplex at 50 Mbps, the fast member |
| ISO1452B | Full duplex at 50 Mbps |
Points to check before this part goes on a BOM
500 kbps is not a limitation that was left in by accident. A slower edge rate radiates less and survives a longer cable, which is why the low rate member is still ordered for building and process networks that were never going to run faster.
The B suffix changes the surge class, not the working voltage. The document prints 1500 VPK of repetitive peak isolation for both the plain and the B strings, and the difference sits in the surge test at 6000 VPK against 10000 VPK.
The bus side needs at least 3 V. A 3.3 V bus is inside the range but a 2.5 V bus is not, and the logic side will happily run at 1.8 V while the bus side sits at 5 V.
The addendum in this revision is offset by one line in places, so the 40 piece tube and the 2000 piece reel are quoted as the family pattern rather than as a confirmed row for this string.
The wide body is 10.30 mm square and the eight millimetre creepage that comes with it is the reason the part exists in this shape. A narrow body would not meet the spacing that a mains-referenced bus needs, however good the barrier itself is.
Both the plain and the B strings are printed with 1500 VPK of repetitive peak isolation. The difference between them is the surge class, so a substitution has to be checked against the surge test the product was certified to, not against the working voltage row.
The fast transient rating of plus or minus 4 kV is quoted for the bus pins with the barrier in place. It is not a reason to omit a transient suppressor on a bus that leaves the building, because the energy in a lightning-induced surge is far above what an on-chip clamp can absorb.
Where the slow member still wins
A run of several hundred metres of twisted pair at 115 kbps or below does not need a 50 Mbps part, and the slower device has more margin against the reflections that a long stub produces. The same argument applies to a retrofit where the existing cable was never specified for data.
What 500 kbps means on a long cable
The rate sets the shortest bit the receiver has to resolve, and a slow bit is what makes a long run possible. At 500 kbps a bit is two microseconds, which is long compared with the reflections that a few tens of metres of twisted pair produce, so a network that was never terminated to the standards of a fast bus can still work.
The trade is throughput. A building network that polls a few dozen nodes a second does not need more, and the slower edge rate radiates less, which is often the reason the low rate member is chosen for a product that has to pass an emissions test in a metal enclosure with a cable gland.
Hot plug, termination and the idle bus
A module inserted into a live bus presents its own termination and its own bias network. The glitch free power up on both rails keeps the receiver from emitting a false start while the module settles, but the connector pin length is what decides whether the bus sees a stub during insertion.
The fail-safe receiver covers the case where no driver is active. With the bus open, shorted or idle the output sits high, so the controller reads a mark rather than a random level, and that behaviour is what allows a protocol to detect an idle line without a separate bias resistor network on every node.
What the bus side supply actually powers
The bus side of an isolated transceiver is a complete RS-485 driver and receiver, so it needs its own rail between 3 V and 5.5 V. That rail has to come from an isolated supply, usually a small transformer driver and a rectifier, and its current has to cover the driver at full load rather than the idle receiver.
The logic side can be anything from 1.71 V to 5.5 V, which is what allows a 1.8 V controller to sit directly on the barrier. Mixing a 1.8 V logic side with a 5 V bus side is normal and does not need a level shifter on either side of the part.
Where this order code fits
It goes where an existing field bus runs at 500 kbps or slower and the barrier has to hold off a mains-referenced ground on the other side. Teams comparing it with a neighbouring part start from our OEM Procurement page, and teams replacing a part that has gone end of life start from the Incoming Inspection Plan page.
Questions buyers ask
Can the B part be replaced by the reinforced part? Mechanically they are the same body and the pin map matches. The substitution is a question of the surge class the end product was tested to, so the certificate has to be checked before the swap.
Does 500 kbps cover a PROFIBUS segment? The device is described as PROFIBUS compatible at a 5 V bus supply. The segment rate has to stay inside 500 kbps, which covers the common 93.75 kbps and 187.5 kbps settings but not 1.5 Mbps.
What happens on a hot swap? The power up and power down are glitch free on both rails, so the receiver does not emit a false start bit while the module is being inserted.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.