ISO1050DWR

Brand: Texas Instruments
Texas Instruments ISO1050DWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO1050DWR — Power Management & Signal Chain | Superb Automation

ISO1050DWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO1050DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO1050DWR: Isolated CAN transceiver with a 5 kV RMS barrier and a 150 ns loop delay

ISO1050DWR is an isolated CAN physical layer device in the 16 pin DW body that meets ISO 11898-2 across a 5000 V RMS barrier, with a 150 ns typical loop delay and bus fault protection from minus 27 V to 40 V in a SOIC-16 body of 16 pins. The ISO1050 is a galvanically isolated CAN transceiver that combines the isolation barrier with the physical layer in one package, so a controller on one side and a bus on the other do not share a ground. The barrier is rated 5000 V RMS in the DW body and 2500 V RMS in the smaller DUB body, the loop delay is 150 ns typical and 210 ns maximum, and the bus pins survive minus 27 V to 40 V. The device provides fail safe outputs so an unpowered node does not hold the bus dominant, and a dominant state timeout that releases the bus if the controller stops.

Order code and package

Order codeISO1050DWR
Functionisolated CAN transceiver, ISO 11898-2
Isolation rating, DW body5000 V RMS
Isolation rating, DUB body2500 V RMS
Loop delay150 ns typical, 210 ns maximum
Bus fault protectionminus 27 V to 40 V
I/O supply support3.3 V and 5 V controllers
Package16 pin SOIC, DW body
Safety approvalsVDE 0884-17 and UL 1577

Electrical parameters that decide the application

Transient immunity50 kV per microsecond typical
Common mode range on the busminus 12 V to 12 V
Comparative tracking indexgreater than 600 V
Fail safe outputsbus goes recessive when the supply is lost
Dominant timeoutreleases the bus if the controller stops driving
Supply current, side 1a few milliamps at 5 V, higher on the bus side
Maximum power dissipation, side 125 mW with a 500 kHz square wave on TXD
Bus pinsCANH and CANL, protected to the stated fault range

Points to check before this part goes on a BOM

Two hundred and ten nanoseconds of maximum loop delay is a large fraction of a bit time and it has to be budgeted with the rest of the segment. At 1 Mbps the bit time is 1000 ns, so the transceiver loop alone is 21 percent of a bit, and the controller's own delay and the cable propagation add to it. At 500 kbps the same delay is 10.5 percent, and at 125 kbps it is 1.7 percent. That is why an isolated node is comfortable at 500 kbps and needs the sample point moved later at 1 Mbps, and why two isolated nodes in series on one segment rarely work at the higher rate.

The 5000 V RMS barrier is a type test rating and the working voltage is a different number. In a battery management system the isolation has to hold the stack voltage continuously, and the relevant figure is the repetitive peak voltage and the pollution degree of the assembly, not the type test. The 600 V comparative tracking index of the package material is the number that describes how the surface behaves under contamination, and it is the reason the part is used in equipment that has to hold off a high voltage for years rather than for a test.

Fail safe outputs are the property that keeps a dead node from taking the bus down. If the supply on the isolated side is lost, the transceiver's output goes to the recessive state rather than to dominant, so the bus stays usable by the other nodes. Without that behaviour a powered down node with a dominant output holds the whole segment at zero, and the symptom is a network that works until one device loses power and then fails completely. The dominant timeout provides the same protection against a controller that stops updating its transmit pin while its supply stays up.

The bus fault range of minus 27 V to 40 V covers the wiring errors that happen in a cabinet: a 24 V supply connected to a bus pin, a ground offset between two cabinets, or a short to a 24 V signal. A transceiver without that range fails on the first wiring error, which is why the range is quoted rather than left implicit. The common mode range for actual communication is narrower at minus 12 V to 12 V, so a node that is faulted to 30 V survives but does not communicate, which is the correct behaviour.

Fifty kilovolts per microsecond of transient immunity is what allows the device to sit across a barrier with a switching converter on one side. A motor drive with a 400 V bus and a 20 ns edge produces 20 V per ns, well inside the rating, and the isolation barrier is what keeps that edge from appearing as a common mode step on the controller side. The number is quoted as typical rather than minimum, so a board that relies on it should leave margin, and the barrier capacitance across the package is the path that couples the transient in the first place.

The I/O side runs from 3.3 V or 5 V, and the bus side needs 5 V for the CAN driver. That means an isolated node needs a supply on each side, usually from a small isolated converter or from a transformer with a winding for the bus side. The isolated supply is the part of the board that is forgotten in the bill of materials, and a node that works on the bench from two bench supplies fails in the cabinet where only one supply exists.

A 16 pin SOIC with a 5 kV barrier has a fixed creepage that cannot be improved by footprint work, so the board spacing outside the package has to match the barrier inside it. A slot under the package, or a cut out in the plane, is what keeps the board from providing a path around the package. The part is qualified to the barrier rating on its own, and the assembly is qualified by the spacing around it, which is why the document gives the package dimensions and the approvals separately.

Where this order code fits

This order code belongs on industrial networks where the bus runs between cabinets at different ground potentials, on motor drives and inverters that carry a floating controller, on battery management systems at the top of a high voltage stack and on any CAN segment that crosses an isolation boundary for safety. It is also the part chosen where the physical layer and the barrier have to fit one package, because a discrete transformer and transceiver pair takes more board area and adds a propagation delay that the loop timing has to absorb. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Can this replace a discrete transceiver and digital isolator? It replaces both and it removes the propagation delay of the separate isolator from the loop. A discrete pair has the isolator delay plus the transceiver delay, which is usually more than the 210 ns maximum of this part, so the timing budget improves as well as the board area. The trade is that the isolated supply is still needed on the bus side.

What data rate does the loop delay support? The delay is 210 ns maximum, so at 1 Mbps it is 21 percent of a bit and the sample point has to be placed accordingly. At 500 kbps it is 10.5 percent and at 125 kbps it is 1.7 percent. The practical limit is set by the whole segment, not by the transceiver alone, and two isolated nodes in series are the case that runs out of margin first.

What happens if the isolated supply fails? The bus side goes to the recessive state through the fail safe behaviour, so the rest of the network keeps working. A node that fails with a dominant output would hold the segment low, which is the failure that fail safe outputs exist to prevent.

Is the 40 V bus fault rating enough for a 48 V system? The operating common mode range is minus 12 V to 12 V and the fault range is minus 27 V to 40 V. A 48 V bus is above the fault rating, so the part is not the right choice for a direct connection to that rail. It suits a 24 V industrial network with wiring errors, which is the range the numbers describe.

SUPERB holds and sources this interface line against the exact order code, with the reel, date code and country of origin stated on the offer. When a bus node has to move to a second part, the Component Lead Time Solutions page sets out the checks that separate a working substitute from one that fails on the bench.