Contact Us

ISO1042QDWRQ1

Brand: Texas Instruments
Texas Instruments ISO1042QDWRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO1042QDWRQ1 — Power Management & Signal Chain | Superb Automation

ISO1042QDWRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO1042QDWRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO1042QDWRQ1: An Isolated CAN FD Transceiver With 70 V Bus Fault Protection

ISO1042QDWRQ1 is an isolated CAN and CAN FD transceiver in a SOIC (DW) body of 16 pins. It runs classic CAN to 1 Mbps and CAN FD to 5 Mbps across a 5000 VRMS barrier, and the bus pins survive plus or minus 70 V of fault while the loop delay stays at 152 ns.

Order code and package

Ordering stringISO1042QDWRQ1
PackageSOIC, 16 pins, DW body, 10.30 mm by 10.30 mm by 7.50 mm
CarrierThe industrial rows print 40 pieces in a tube and 2000 pieces on a large reel
Moisture levelLevel 3, 260 C peak reflow, 168 hour floor life on the printed rows
Temperature rangeMinus 40 to plus 125 degrees Celsius
Logic side supply1.71 V to 5.5 V, covers 1.8, 2.5, 3.3 and 5 V logic
Bus side supply4.5 V to 5.5 V
Part markingISO1042 on the industrial rows
Addendum noteThe automotive Q1 rows are not printed here, ISO1042-Q1 is a separate family
Smaller bodySOIC 8 pins, DWV body, 5.85 mm by 5.85 mm by 11.50 mm

Electrical parameters that decide the application

Classic CAN rateUp to 1 Mbps
CAN FD rateUp to 5 Mbps
Loop delay152 ns, transmit to receive
Bus fault protectionPlus or minus 70 V DC on the bus pins
Common mode rangePlus or minus 30 V
ESD on the bus pinsPlus or minus 16 kV human body model
Common mode transient immunity100 kV per microsecond
Isolation rating5000 VRMS for one minute per UL 1577
Working voltage1060 VRMS
Transient and working peak7071 VPK transient, 1500 VPK repetitive peak
UndervoltageProtection on both VCC1 and VCC2
TXD timeoutDominant time out protection against a stuck driver
Unpowered bus behaviourIdeal passive, high impedance bus terminals
StandardISO 11898-2:2016 physical layer

Family variants and how they differ

ISO1042DWIndustrial 16 pin version of the same die
ISO1042DWVEight pin small body for a board with no room for the wide part
ISO1042BThe B revision rows, printed alongside the plain rows in the same addendum
ISO1044Smaller and slower sibling for classic CAN only
ISO1050Earlier isolated CAN transceiver, the part most often replaced
ISO1410BIsolated RS-485 when the field bus is not CAN

Points to check before this part goes on a BOM

The automotive rows are not in this document. Everything printed here is the industrial ISO1042 and the B revision, so the Q1 reel size, the marking and the temperature grade have to come from the ISO1042-Q1 addendum rather than being copied across.

Level 3 with a 168 hour floor life is unusual for a part this small. A reel that sat open over a long shutdown needs a bake before reflow, and the label on the reel is the authority for that.

70 V of bus fault protection is a survival rating for the pins, not an operating range. The common mode window that still guarantees communication is plus or minus 30 V.

The 152 ns loop delay is the number that decides whether a CAN FD data phase can be timed from the controller without a transceiver delay compensation figure in the timing budget.

The eight pin version is 5.85 mm square and it carries the same die and the same barrier as the sixteen pin body. The smaller body has less creepage, so the isolation class has to be read from the body that is actually fitted.

Because the logic side accepts 1.71 V, a 1.8 V controller can drive this part without a level shifter, which is unusual for an isolated transceiver and is the reason it appears in newer products.

The passive behaviour with no supply is worth stating in a product manual. A node that is unpowered but still connected must not load the bus, and this part presents a high impedance rather than a clamp.

Isolated CAN in a vehicle or a drive cabinet

A CAN segment that runs between two cabinets at different ground potentials needs the barrier, and the reason is usually not the data rate but the fault energy that a long bus can deliver into the transceiver when a harness shorts to a 24 V rail.

The TXD dominant time out is the protection that keeps a stuck controller from holding the bus dominant forever. It is invisible in normal operation and it is the reason a bus recovers after a controller reset without a power cycle of the whole segment.

The CAN FD timing budget with a barrier in the path

A CAN FD frame has an arbitration phase at the nominal rate and a data phase at the faster rate, and the transceiver loop delay sits inside the data phase timing. At 152 ns this part is fast enough that the controller delay compensation figure can be calculated from the data sheet rather than measured on a bench.

The barrier does not change that number, which is the point of quoting a loop delay rather than a propagation delay. A part that quotes only one direction leaves the reader to add the transmit and receive paths together, and the sum is what the timing tool needs.

Surviving a fault on a 24 V harness

The plus or minus 70 V bus fault rating is what allows the part to sit on a harness that can be shorted to a truck rail or to a welding return without an external protection network. The common mode window that still guarantees communication is narrower at plus or minus 30 V, and the two numbers answer different questions.

The other protection that matters in the field is the dominant time out. A controller that hangs with its transmit line held low would otherwise hold the whole segment dominant, and every other node would stop talking until the harness was unplugged.

The isolated 5 V rail behind the transceiver

An isolated CAN node needs a 5 V rail on the bus side, and that rail has to be generated on the isolated side from the logic side supply. The transceiver draws its driver current from that rail, so the converter has to be sized for the dominant bit current rather than the average.

The undervoltage protection on both rails is what prevents a half powered node from driving a corrupted frame onto a live bus. When either rail falls below its threshold the driver goes passive, which is the behaviour the rest of the segment needs during a brownout.

Where this order code fits

It is specified where a CAN or CAN FD segment crosses between cabinets or between a vehicle bus and an isolated controller, and where a harness fault has to be survived rather than fused away. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Does it support CAN FD at the full 5 Mbps data phase? Yes, up to 5 Mbps in FD mode and 1 Mbps in classic mode, on the same pins, with the same loop delay quoted for both.

What replaces the ISO1050? This family is the usual move, because the loop delay is shorter and the bus fault rating is higher. The pin map is not identical, so the substitution has to be checked pin by pin.

Why does the reel have a 168 hour floor life? The printed rows carry moisture level 3, which allows 168 hours out of the bag at 30 C and 60 per cent relative humidity before a bake is required.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.