The ISO1042DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1042DWR: isolated CAN FD transceiver with 70 V bus fault protection
ISO1042DWR is an isolated controller area network transceiver in a SOIC body of 16 pins. It places a silicon dioxide barrier between a CAN bus and the local controller, passing classic frames at 1 Mbps and flexible data rate frames up to 5 Mbps with a loop delay of 152 ns. The DWR order code is the 16-pin wide body SOIC on a reel.
Order code and package
| Order code | ISO1042DWR |
| Package | 16-pin wide body SOIC, DW |
| Packing | tape and reel |
| Data rate | 1 Mbps classic CAN, 5 Mbps CAN FD |
| Isolation | 5000 V RMS withstand, 1060 V RMS working, 1500 V peak repetitive |
| Bus fault protection | 70 V DC on the bus pins |
| Common mode | plus or minus 30 V |
| Supply | VCC1 1.71 V to 5.5 V, VCC2 4.5 V to 5.5 V |
Electrical parameters that decide the application
| Loop delay | 152 ns, transmit to receive round trip |
| Bus ESD | 16 kV human body model on the bus pins |
| Supply current side 1 | about 3 mA at 5 V with the bus dominant |
| Temperature range | minus 40 to plus 125 degrees |
| Barrier type | silicon dioxide, basic and reinforced options |
| Unpowered state | bus pins present a passive high impedance |
Family variants and how they differ
| ISO1042DW | 16-pin wide body, 5000 V RMS, this order code |
| ISO1042DWV | 8-pin body, 5000 V RMS, same silicon |
| ISO1044B | 8-pin body, 3000 V RMS, smaller common mode range |
| ISO1042BDW | basic insulation grade of the same part |
Points to check before this part goes on a BOM
The 5000 V RMS figure is a one minute withstand test, and the number that belongs in a working voltage statement is the 1060 V RMS working voltage or the 1500 V peak repetitive isolation voltage. A 400 V traction bus sits comfortably inside the working figure, while a customer who quotes the withstand number as if it were a continuous rating is overstating what the barrier carries.
Both sides need their own supply, and side two is restricted to 4.5 V to 5.5 V while side one accepts 1.71 V to 5.5 V. A 5 V bus transceiver therefore requires a 5 V isolated rail on the cable side, and the isolated supply is a separate line item that a bill of materials built from the transceiver alone will not show.
Loop delay of 152 ns is a round trip through both directions of the barrier, not a one way propagation figure. In a CAN FD network with a 5 Mbps data phase, a bit is 200 ns, so the delay plus the transceiver and cable delays is what sets the maximum bus length in the fast phase.
The 70 V bus fault rating is what survives a short to a 48 V or 60 V battery rail in a vehicle harness. A 12 V or 24 V system is far inside it, and a 72 V traction system is outside it, so the fault figure has to be checked against the highest battery voltage in the harness rather than against the nominal rail.
Common mode range of plus or minus 30 V is the range over which the receiver still resolves the differential signal while ground potentials differ. Ground offset beyond that range is the usual cause of a bus that works on the bench and fails on a long harness, and it is a reason to keep the isolated part rather than a non isolated transceiver with a common ground.
The dominant time out feature turns off a driver that has been held dominant for longer than the internal limit, which prevents one faulty node from locking the whole bus. Firmware that expects a stuck TXD to hold the bus dominant will see the driver release instead, and the resulting error frames are the intended behaviour rather than a fault in the part.
Unpowered bus pins are a passive high impedance, so a node that loses its supply does not load the bus. That is the property that keeps a multi node harness alive during a module brownout, and it only holds while the barrier is intact and VCC2 is absent, not while VCC2 is at a low but nonzero voltage.
Termination on an isolated CAN segment is still two 120 ohm resistors at the ends, and the isolated node needs its own split termination to keep the common mode stable. The barrier does not replace the termination, and a segment that loses its far end terminator shows up as increasing error frames with cable length rather than as a dead bus.
The isolated supply on side two has to deliver the transceiver current plus whatever the termination draws. A driver transmitting a dominant bit into a 60 ohm load draws far more than the 3 mA quiescent figure, and a transformer driver sized from the quiescent number browns out on the first frame rather than on the hundredth.
Where this order code fits
It is used in electric vehicle and hybrid controllers, motor drives, battery management harnesses, industrial networks and any CAN segment that crosses a safety barrier. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Does it work at 3.3 V on both sides? Side one can run from 3.3 V, side two needs 4.5 V to 5.5 V because the bus driver is a 5 V circuit. A 3.3 V only build needs a different order code or a 5 V isolated rail.
Is the 5000 V RMS rating a continuous rating? No. It is a 60 second withstand test, and the continuous working figure is 1060 V RMS with 1500 V peak repetitive isolation.
Can it be used without an isolated supply? It will pass data, but the barrier is then only a capacitive link and the ground loop it was bought to break still exists.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.