INA232AIDDFR
Product Specifications
INA232AIDDFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA232AIDDFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA232AIDDFR: 48 V, 16 bit monitor with a 10 nA input bias current
The INA232AIDDFR is a 16 bit current, voltage and power monitor in an 8 pin SOT-23-THIN body that senses on rails up to 48 V while running from a supply as low as 1.7 V. The number that separates it from the older 12 bit monitors in the same family is the input bias current: 10 nA maximum, which is two to three orders below what a resistor divider or a large shunt can tolerate. That is what allows a 1 ohm shunt to be used on a 20 mA standby rail, where the shunt drop at 20 mA is 20 mV and a 1 uA bias current would already be 5 percent of the signal.
The full scale range is selectable between 20 mV and 80 mV, giving 16 bits over a window that is either 0.3 uA or 1.2 uA per step on a 1 ohm shunt. Gain error is 0.3 percent maximum and offset 50 uV maximum, with the ADC, the multiplier and the calibration register all inside the package. The device alerts on over and under current as well as over and under voltage, so one part covers both the measurement and the protection threshold on a hot swap rail.
Key data for the INA232AIDDFR
| Common mode | 0.3 V to 48 V on the input pins, independent of the supply, high side or low side |
| Full scale | 20 mV or 80 mV differential, selected in the configuration register, 16 bit resolution over either window |
| Accuracy | Gain error 0.3 percent maximum, offset 50 uV maximum, input bias current 10 nA maximum |
| Supply | 1.7 V to 5.5 V, 300 uA typical quiescent, 1.2 V compliant I2C and SMBus interface |
| Timing | Conversion time 140 us to 8.244 ms with averaging from 1 to 128 samples |
| Alert | Over and under current plus over and under voltage thresholds on one open drain ALERT output |
Body, marking and reel data
| Body | DDF, 8 pin SOT-23-THIN, the low profile body at 1.1 mm maximum height |
| Reel | 3000 pieces on a large reel for the R suffix |
| Finish | NIPDAU at moisture level 1, unlimited floor life, no bake step in the assembly flow |
| Address set | The A option uses one set of four addresses from the A0 pin, the B option a different set, together covering eight devices |
| Temperature | Minus 40 C to 125 C, specified over the full range rather than at 25 C only |
Where a 48 V monitor with nanoamp bias earns its place
Telecom line cards, power over ethernet ports, base station remote radio heads and industrial 48 V buses all need a current reading somewhere between the input connector and the first converter. Two things make that awkward on a 48 V rail. The first is that a shunt large enough to give a usable signal at 1 A drops too much at 20 A, so the monitor has to resolve a small differential on a large common mode, which is what the 0.3 percent gain error and the 110 dB class of rejection are for. The second is that any bias current flowing in the shunt adds directly to the reading, so a 10 nA input is what makes a 1 ohm shunt usable at all.
The 20 mV full scale setting is the one to reach for on a standby rail and the 80 mV setting for a load rail. On a 10 milliohm shunt the difference between them is 2 A against 8 A of headroom, which is the whole range of a small DC/DC converter. The alert thresholds are programmed in the same units as the measurement register, so a threshold set once survives a change of shunt only if the calibration register is rewritten at the same time. Where a board is moving between this part and the 12 bit INA234 or the 85 V INA238, our amplifier cross reference puts the three side by side on resolution, common mode and bias current, and the drop in replacement check note covers what has to be re-verified when the register map is close but not identical.
Buyer questions on the INA232AIDDFR
Does 48 V mean a 48 V battery can be connected directly? The input pins tolerate minus 0.3 V to 48 V in the recommended range, so a nominal 48 V lead acid pack that reaches 58 V during an equalise charge is outside it. A 48 V regulated rail with normal tolerance is inside.
Why does the supply go down to 1.7 V? Because the monitor is often powered from the same low voltage housekeeping rail as the microcontroller, and on a 1.8 V logic board that rail is 1.8 V, not 3.3 V. The bus pins are 1.2 V compliant for the same reason.
Are the A and B options interchangeable? Only in the sense that the die is the same. The address set differs, so a board laid out for A cannot simply take B unless the host is rewritten to look at the other addresses.
Availability and ordering notes
INA232AIDDFR is active at 3000 pieces on a large reel with NIPDAU at moisture level 1. Both the A and the B address options are published in the same DDF body at the same quantity, so the letter is a host software decision and not a packing one. The package drawing in this revision lists the body as 1.1 mm maximum height, which is the number that matters when the monitor sits under a shield can. Where the board has to be inspected for the correct address option after reflow, the marking and the reel label are the only two places the letter appears, and our incoming inspection plan note describes how we separate the two in a goods in check.