INA228AIDGSR
Product Specifications
INA228AIDGSR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA228AIDGSR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA228AIDGSR: 85 V power and energy monitor with a 20 bit converter, 1 uV offset and an I2C interface
INA228AIDGSR is a power, energy and charge monitor in the ten pin VSSOP body that measures a shunt across a common mode from 0.3 V below ground to 85 V, converts with a 20 bit delta sigma stage at 1 uV of maximum offset, and reports over I2C in a VSSOP body of 10 pins. The INA228 measures current, bus voltage, power, energy, charge and die temperature with one converter and one pair of inputs. The shunt input has two ranges, plus or minus 163.84 mV and plus or minus 40.96 mV, the bus input accepts 0 V to 85 V, and the supply is 2.7 V to 5.5 V. The interface is I2C with an alert output, and the body is a ten pin VSSOP with a 1.2 V logic threshold.
Order code and package
| Order code | INA228AIDGSR |
| Function | power, energy, charge and temperature monitor |
| Common mode input range | minus 0.3 V to 85 V |
| Bus voltage input range | 0 V to 85 V |
| Shunt input range | plus or minus 163.84 mV or plus or minus 40.96 mV |
| Resolution | 20 bit delta sigma converter |
| Supply voltage | 2.7 V to 5.5 V |
| Interface | I2C with an alert output |
| Package | ten pin VSSOP, DGS body |
| Document | INA228 data sheet, SBOSA24 class |
Electrical parameters that decide the application
| Shunt offset voltage | plus or minus 0.3 uV typical, plus or minus 1 uV maximum |
| Offset drift | plus or minus 0.01 uV per C maximum |
| Gain error | plus or minus 0.05 percent maximum |
| Gain error drift | plus or minus 20 ppm per C maximum |
| Common mode rejection | 154 dB minimum, 170 dB typical |
| Power accuracy over the temperature range | 0.5 percent of full scale maximum |
| Energy and charge accuracy | 1.0 percent of full scale maximum |
| Alert response time | 75 us |
| Temperature sensor accuracy at 25 C | plus or minus 0.15 C typical, plus or minus 1 C maximum |
| Temperature sensor accuracy over the range | plus or minus 0.2 C typical, plus or minus 2 C maximum |
| Supply current | 640 uA typical, 750 uA maximum, 1.1 mA over the temperature range |
| Shutdown current | 2.8 uA typical, 5 uA maximum |
| Power up time | 300 us |
| Logic input high threshold | 1.2 V |
| Operating temperature range | minus 40 C to 125 C |
Points to check before this part goes on a BOM
One microvolt of maximum offset across a 1 milliohm shunt is 1 mA of apparent current, and across a 10 milliohm shunt it is 0.1 mA. That is what makes the 40.96 mV range usable: with a 1 milliohm shunt, a 20 A load develops 20 mV, which sits in the middle of the smaller range and leaves the larger range free for the inrush event that follows a hot plug. The range is selected by a register bit, so firmware can switch between the two as the load moves.
The energy and charge registers are the reason this part is not simply a current monitor. Accumulating energy in firmware means sampling at a fixed rate and living with the jitter and the missed samples, and any offset in the current reading integrates into a charge error that grows without bound. With an offset drift of 0.01 uV per C, a 40 C swing is 0.4 uV, which across a 1 milliohm shunt is 0.4 mA, and over a thousand hours that is 400 mAh of charge that never flowed. The hardware accumulator does not remove that drift, but it does remove the sampling error on top of it.
The 154 dB minimum common mode rejection is what allows the shunt to sit at the top of an 85 V bus. A rejection of 154 dB attenuates a 60 V common mode step to 0.38 uV referred to the input, which is below the 1 uV offset. That comparison is the working case: below that level the common mode no longer contributes, and above it the input divider and the shunt wiring become the limiting terms.
Supply current of 640 uA typical, rising to 1.1 mA over the temperature range, is 15 mAh a day and about 2 Ah over a year of continuous operation. That is a system monitor, not a battery powered sensor. A product that sleeps on a coin cell has to switch the monitor off between readings, and the shutdown current of 2.8 uA plus the 300 us power up time then becomes the budget: a reading every ten seconds costs about 3 uA of average current.
The temperature channel is on the die, not on the board, so it reads the monitor's own junction rather than the air around the shunt. With a 1 C maximum error at 25 C and 2 C over the range it is useful for compensating the shunt and for a thermal alarm, and it is not a substitute for a sensor placed where the heat is. The 75 us alert response is what makes it useful for a fast overcurrent: the alert can be tied to a comparator or a controller input and act long before a polled read completes.
The logic threshold of 1.2 V means the I2C pins work with a 1.8 V bus as well as with 3.3 V, and the supply can be 5 V while the bus is 1.8 V, which is the arrangement on a board with a low voltage microcontroller and a 5 V analogue section. The pull ups belong on the bus side, and their value is set by the bus capacitance and the 400 kHz or 1 MHz rate rather than by the monitor, which sinks a fixed current and does not care about the rail it is pulled to within its absolute maximum.
The bus voltage input accepts 0 V to 85 V independently of the shunt input, so the voltage sense can sit on the load side of the shunt or on the source side, and the power register multiplies whichever it is wired to. A monitor wired to the source side reports the power delivered to the shunt as well as to the load, which is 20 mW at 20 A through a 1 milliohm shunt, or 0.5 percent of a 4 W reading. Small, and it is exactly the kind of term that shows up when a power budget is compared against a bench meter.
Where this order code fits
This order code belongs on 48 V and 60 V telecom and datacom rails, battery pack monitors, solar strings, server power shelves and any board where the energy or charge total has to be accumulated rather than inferred. It is chosen when a system needs a digital power reading with a defined accuracy at full scale, because the energy and charge registers do the integration in hardware and remove the drift that comes from sampling in firmware. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
Which shunt range should be used? The 40.96 mV range gives the finer resolution and the 163.84 mV range gives the headroom. With a 1 milliohm shunt and 20 A the sense voltage is 20 mV, which fits the smaller range with room for a 100 percent overload. With a 10 milliohm shunt the same current gives 200 mV, which needs the larger range or a smaller shunt. The offset of 1 uV is a smaller fraction of the larger sense voltage, so the decision is a trade between resolution and offset error.
Is this part suitable for a battery fuel gauge? For a pack monitor, yes: the charge and energy accumulators run in hardware and the 1 percent full scale figure is defined. For a small battery that sleeps, the 640 uA supply current rules it out unless the monitor is switched. The offset drift of 0.01 uV per C is the term that matters over long integration, because it becomes a charge error that accumulates rather than an instantaneous one.
What does the 0.5 percent power accuracy figure include? It is a full scale figure over the temperature range and it covers the current and voltage paths and their multiplication. It is not a percentage of reading, so at 10 percent load the error is a larger fraction of the actual power. A system that needs 1 percent at 10 percent load has to look at the offset and gain terms separately rather than at the headline number.
Can the alert pin drive a protection circuit directly? It responds in 75 us, which is fast enough to signal a controller or a comparator, and it is not a protection device in itself. Its output polarity and latch behaviour are register options, so a circuit that depends on the pin for a fast shutdown has to define what clears it. The usual arrangement is to have the alert interrupt a controller that then decides, with the monitor providing the measurement rather than the trip.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.