INA2191A3IYBJR
Product Specifications
INA2191A3IYBJR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA2191A3IYBJR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA2191A3IYBJR: dual 100 V/V with 12 uV offset and 85 uA total
The INA2191A3IYBJR is the 100 V/V dual of the INA191 family in a DSBGA 12 pin body, and it is the practical middle of the range. Common mode spans 0.2 V below ground to 40 V above it, the supply runs 1.7 V to 5.5 V, offset is 12 uV maximum with 0.13 uV per degree of drift, and gain error is inside 0.25 percent on the A3 row. Bandwidth is 35 kHz with a 10 pF load. Both channels draw 85 uA typical and 96 uA maximum over temperature, with 200 nA maximum in shutdown.
At gain 100 the maximum shunt drop on a 3.3 V supply is about 32 mV, so a 10 milliohm shunt covers 3.2 A and a 100 milliohm shunt covers 320 mA. That is the range of a battery pack in a handheld instrument, a medical pump or a portable radio, and it is where the 12 uV offset does the most work: 12 uV through 100 milliohm is 120 uA, so the bottom of the range stays readable instead of drowning in offset.
Key data for the INA2191A3IYBJR
| Gain | 100 V/V per channel, with 25, 50, 200 and 500 as the other four options |
| Input | Common mode minus 0.2 V to plus 40 V, bidirectional, 100 pA typical bias current |
| Accuracy | Offset 12 uV maximum, 0.13 uV per degree drift, gain error within 0.25 percent on A2 to A5 rows |
| Quiescent | 85 uA typical for both channels, 96 uA maximum over temperature, 200 nA maximum shutdown |
| Bandwidth | 35 kHz at gain 100, 45 kHz at gain 25 and 27 kHz at gain 500 |
| Supply | 1.7 V to 5.5 V, DSBGA 12 pin at 1.79 mm square |
Body, marking and reel data
| Body | YBJ, DSBGA 12 pin, 1.79 mm square, the dual body of the family |
| Reel | 3000 pieces on a large reel, the only packing printed for this string |
| Finish | SNAGCU, moisture level 1 at 260 C with unlimited floor life |
| Marking | 29L1 on the A3 row, four characters, distinct from 29J1 on the A1 row |
| Temperature | Minus 40 C to 125 C, offset and gain specified across the full range |
Choosing 100 V/V over 25 or 500
Gain 100 is the compromise that most battery instruments land on. It resolves 120 uA through a 100 milliohm shunt and still covers 3.2 A through 10 milliohms, so one part number serves both the standby measurement and the working current, which is unusual. Gain 25 would cover more current and lose the standby reading to offset, gain 500 would read microamps and saturate at a few hundred milliamps.
There is a production argument too. One gain means one calibration table, so the test station does not switch ranges between the standby measurement and the load measurement, and the operator does not need two fixtures for one board.
Where the instrument has to report both ends, the answer is usually two channels at different gains rather than one channel with a programmable gain, because the INA2191 already carries two independent channels in one body and two calibration tables in one package. Our amplifier cross reference lists the five gains with offset and quiescent current side by side, and the medical device components page covers how a two gain pair is kitted and traced for an instrument build.
Buyer questions on the INA2191A3IYBJR
Can the two channels run different gains? Not in one package. The gain letter applies to both channels, so two gains mean two packages or a different family arrangement.
Is the shutdown current really 200 nA? That is the maximum over temperature for the dual with both enables low. At 25 C the typical figure is 20 nA, which is why the part can sit on a battery rail without a load switch.
What limits the common mode to 40 V? The input stage process. A 48 V bus needs either a divider or one of the 80 V families, and the divider adds an error term that has to be calibrated.
Availability and ordering notes
The A3 string is active at 3000 pieces on a large reel with SNAGCU plating and moisture level 1, marking 29L1, distinct from the A1 row's 29J1. Because the two markings differ by one character, a line that runs both gains should read the reel label and not the die marking. We confirm the gain letter, the body and the packing before shipping, and the plating and date code travel on the date code management note. The 12 uV offset figure is a maximum over temperature and not a typical at 25 C, which is the difference between a claim and a guarantee for an instrument that has to hold its accuracy in a warm room.