INA213CQDCKRQ1
Product Specifications
INA213CQDCKRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA213CQDCKRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA213CQDCKRQ1: 50 V/V automotive monitor with the C grade error budget
The INA213CQDCKRQ1 is the 50 V/V member of the INA21x-Q1 family with the C accuracy grade, in a 6 pin SC70 body. It reads a shunt from 0.3 V below ground to 26 V above it, runs from 2.7 V to 26 V, and is qualified to AEC-Q100 grade 1, minus 40 C to plus 125 C ambient, with functional safety documentation available. Offset is 100 uV maximum on the family, drift 0.5 uV per degree, gain drift 10 ppm per degree and gain error 0.5 percent over temperature on the C row against 1 percent on the A and B rows. Bandwidth at gain 50 is 80 kHz.
The automotive family differs from the industrial INA21x in one more way than the grade letter. The offset limit is 100 uV on the Q1 rows against 35 uV on the industrial INA210, so the automotive part is not simply the same die with a certificate: the specification window is wider and that has to be priced into the error budget. Grade 1 also means the ambient range is guaranteed rather than a junction figure with a derating note.
Key data for the INA213CQDCKRQ1
| Gain | 50 V/V, with 75, 100, 200, 500 and 1000 available in the same Q1 family |
| Input | Common mode minus 0.3 V to plus 26 V, bidirectional, independent of the 2.7 V to 26 V supply |
| Accuracy | Offset 100 uV maximum on the Q1 rows, 0.5 uV per degree drift, gain error 0.5 percent on the C row |
| Bandwidth | 80 kHz at gain 50 with a 10 pF load, the widest row of the six gains |
| Supply | 2.7 V to 26 V, 100 uA maximum quiescent current, no enable pin |
| Qualification | AEC-Q100 grade 1, minus 40 C to 125 C ambient, functional safety documentation available |
Body, marking and reel data
| Body | DCK, SC70 6 pin, 2.00 mm by 1.25 mm, the only body the Q1 family is printed in |
| Reel | 3000 pieces on a large reel, with the G4 row of the same body as a separate order code |
| Finish | NIPDAU, moisture level 2 at 260 C with a one year floor life |
| Marking | 17G on the C3 Q1 row, three characters that carry neither gain nor grade |
| Grade | Grade 1, HBM level 2 and CDM level C6 against the industrial rows |
Reading current on a vehicle rail without a shunt amplifier chain
An automotive current sense channel has three jobs that a lab bench does not: it has to survive a load dump on the harness, it has to keep its offset across a cabin that goes from minus 30 C to plus 85 C, and it has to be documented for a functional safety file. The INA213CQDCKRQ1 answers the second and third directly and the first only partly. The common mode window covers minus 0.3 V to 26 V, which is the rail plus a transient, and anything above that needs an external clamp or a series resistor sized against the input current limit.
The C grade is the right purchase when the reading is used in a control loop rather than a fault latch, because half a percent of gain error at full scale is what separates a torque estimate from a torque guess. Where a programme needs to show a second source, our defense grade components page and the amplifier cross reference set out how we record qualification level next to the electrical parameters.
Buyer questions on the INA213CQDCKRQ1
Is the Q1 offset really worse than the industrial part? Yes, 100 uV maximum against 35 uV. The automotive specification window is wider, so a customer moving from the industrial row has to recheck the bottom of the measurement range.
Does grade 1 cover the whole engine bay? It covers minus 40 C to 125 C ambient on the board. Local heating from a nearby regulator still has to be added, and the junction limit sits above the ambient limit.
Can the same board use the industrial and automotive rows? Mechanically yes, the SC70 footprint is the same. Electrically the offset and the qualification differ, so the error budget and the documentation have to be checked rather than assumed.
Availability and ordering notes
The C3 Q1 string is active at 3000 pieces on a large reel with NIPDAU and moisture level 2, marking 17G, and the G4 row of the same body is a separate order code with its own addendum line. The automotive family has its own data sheet, SBOS475, and an automotive string cannot be verified against the industrial INA21x sheet. We check the grade, the gain and the body on the reel label and record them on the sourcing audit trail. The offset difference against the industrial row is the part of the quote a programme manager usually questions first, so it is stated in the offer rather than discovered at qualification.