Contact Us

INA183A1IDBVR

Brand: Texas Instruments
Texas Instruments INA183A1IDBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA183A1IDBVR — Power Management & Signal Chain | Superb Automation

INA183A1IDBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA183A1IDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA183A1IDBVR: zero drift current sense with a 10 mV full scale shunt

The INA183 is a zero drift current shunt monitor that works from a 2.7 V to 26 V common mode range and gives a voltage output at a fixed gain. The A1 member is the gain of 50 V/V, and the figure that defines the family is the offset: 25 microvolts typical and 170 microvolts maximum over temperature, with 0.1 microvolts per degree of drift typical. That combination is what allows a full scale shunt drop of only 10 mV, so a 10 A rail can be measured across a 1 milliohm resistor and dissipate 100 mW instead of the watt a 100 mV full scale part would burn. Common mode rejection is 100 dB minimum and 120 dB typical, and quiescent current is 83 microamps typical, 130 maximum.

The zero drift architecture chops the input stage, which removes the low frequency noise and the offset walk that a conventional pair shows over temperature. The price is a modest bandwidth, 80 kHz at a gain of 50, which is still far above what a motor current loop or a battery gauge needs. The output swing reaches within 0.2 V of the input rail at the top and 5 mV of ground at the bottom, so a unidirectional measurement keeps its resolution across the whole range.

Key data for the INA183A1IDBVR

Gain50 V/V fixed, the lowest of the three members, so 10 mV of shunt drop becomes 500 mV of output
Offset25 microvolts typical and 170 microvolts maximum over temperature, 0.1 microvolts per degree typical drift
Common mode2.7 V to 26 V, with rejection of 100 dB minimum and 120 dB typical at 10 mV of sense voltage
SupplySupplied from the IN+ pin, 83 microamps typical and 130 microamps maximum quiescent current
Bandwidth80 kHz at this gain, 30 kHz at a gain of 100 and 14 kHz at 200, with a 0.4 V per microsecond slew rate
AccuracyGain error within 0.4 per cent over temperature, nonlinearity 0.01 per cent, noise 25 nV per root hertz

Body, marking and reel data

BodyDBV, SOT-23 5 pin, 3000 pieces on a large reel, 180 mm carrier
Marking2BRQ on the A1 row, 2BSQ on the A2 row, which is how the gain is read off a mixed bag
FinishNIPDAU or SN depending on the row, moisture level 2 with a one year floor life
GradeAmbient minus 40 C to 125 C on the active rows, wider than the older shunt monitors in this catalogue

Where the zero drift offset buys accuracy

A conventional current sense amplifier has an offset in the hundreds of microvolts, so a 10 mV full scale circuit spends a large part of its range on an error that never goes away. The INA183 moves that offset down to 25 microvolts typical, which is 0.25 per cent of a 10 mV full scale, and the drift is small enough that a factory calibration holds over the temperature range of the product. The result is a current measurement that can be used for a battery gauge rather than only for a fault trip.

The single supply and the low quiescent current also mean the part can run from the rail it monitors, with the supply taken from the IN+ pin and a 0.1 microfarad capacitor beside it. That is the arrangement in a battery monitor, a power tool, a lighting driver or a small inverter. Where a customer needs a bidirectional reading, the family is unidirectional and a reference offset has to be added externally. Our power management cross reference lists the zero drift monitors by gain and common mode range, and the cost reduction page covers the shunt and monitor combination as a single choice.

Buyer questions on the INA183A1IDBVR

Can it measure 10 A with a 1 milliohm shunt? Yes, and that is the case the family was built for. The 10 mV drop at 10 A gives 500 mV at a gain of 50, which is comfortably inside the output swing and well above the 170 microvolt maximum offset.

Does the supply have to come from the monitored rail? It is supplied through the IN+ pin, so the part is normally powered from the rail it measures, with a 0.1 microfarad decoupling capacitor at the pin. The common mode floor of 2.7 V is also the supply floor.

Is the bandwidth of 80 kHz enough for a motor? For a current loop closing at a few kilohertz, yes. A circuit that has to catch a commutation spike uses a faster part with a lower gain and a larger shunt, and accepts the larger offset that comes with it.

Availability and ordering notes

The three gain options share one body and one reel size, so a customer can change the gain without changing the board. The marking carries the gain, which matters when several gain options sit in the same kit. We quote the marking alongside the orderable code so the goods inward check can confirm the gain from the package, and the procedure for that check is on our incoming inspection plan page.