Product Overview
The INA125P from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA125P: an instrumentation amplifier with a bridge excitation reference inside it
The INA125 is an instrumentation amplifier with a precision voltage reference on the same die, and that combination is aimed at one job: a bridge sensor that needs excitation and a differential amplifier in a single package. The reference is pin selectable at 1.24, 2.5, 5 or 10 V, the amplifier takes a gain from 4 to 10,000 with one external resistor, and the whole part draws 460 µA with a sleep pin for duty cycled operation.
For a pressure or load transducer the reference is the half of the problem that a plain amplifier does not solve. A bridge with a 2 mV per volt sensitivity on a 5 V excitation gives 10 mV at full scale, and the excitation has to be stable because the sensitivity is proportional to it. Putting the reference and the amplifier on one die means the two drift together, which is a smaller error than two separate parts with independent temperature coefficients.
The INA125P rows as the addendum publishes them
| Part class | Instrumentation amplifier with precision voltage reference |
| Vendor status | ACTIVE, production data |
| Data sheet | SBOS060 |
| Reference voltages | 1.24 V, 2.5 V, 5 V and 10 V, pin selectable |
| Sleep mode | Yes, dedicated pin |
| Gain equation | G = 4 + 60 kΩ divided by RG |
| Gain range | 4 to 10,000 V/V |
| Input offset voltage | 250 µV maximum |
| Offset drift | 2 µV per degree maximum |
| Input bias current | 20 nA maximum |
| Common mode rejection | 100 dB minimum |
| Input noise at 1 kHz | 38 nV per root Hz |
| Quiescent current | 460 µA |
| Supply range | Single supply 2.7 V to 36 V |
| Body | PDIP, N outline, 16 pins |
| Carrier | 25 pieces per tube |
| SOIC sibling | INA125U and INA125UA, SO-16 body |
| Moisture level | Not applicable to this package type |
| Temperature range | Minus 40 to plus 85 degrees |
The 16 pin body is a consequence of the reference, not of the amplifier. The reference needs its own output pin, its own sense connection and a set of taps for the four voltages, and those pins are what occupy the extra eight positions. A board laid out for a plain eight pin amplifier cannot take this part without a new footprint, which is the first thing to check when a customer proposes it as a substitute.
Bridge excitation, ratiometric measurement and the reference taps
A bridge sensor's output is proportional to its excitation, so the cleanest measurement is ratiometric: the same voltage that excites the bridge is the reference of the converter, and the two drifts cancel. The INA125 makes that possible by bringing the reference out on a pin, but the converter has to be able to take that node as its reference, and the node has a finite output impedance. A converter with a high impedance reference input works directly; one that draws current needs a buffer.
The four selectable voltages are set by strapping pins, not by a resistor divider, which is why they are accurate. A 2.5 V tap on a 5 V supply is the usual choice for a 350 Ω bridge, and a 10 V tap needs a supply above 12 V. The reference's current capability is finite, so a bridge with four 350 Ω resistors drawing 14 mA at 5 V needs a pass transistor or a lower excitation voltage, and that limit is the one that decides whether this part can drive the bridge directly.
Sleep, duty cycle and a 460 µA budget
The sleep pin is what makes this part interesting for a battery instrument. A transducer that is read once a second can be powered down between readings, and the reference and the amplifier go down together, which is the reason to have them on one die. The wake up time then becomes the constraint: a reference that takes milliseconds to settle limits the duty cycle to something slower than a fast multiplexed system, and the reading has to be taken after the settling time, not at the moment the pin goes high.
At 460 µA the running current is modest but not micropower, so a circuit that leaves the part on continuously will flatten a coin cell in weeks. The arithmetic is straightforward: a 200 mAh cell at 460 µA lasts 430 hours, which is 18 days. Duty cycling to 1 per cent brings that to five years, and the sleep current, not the running current, then decides the life.
The reference is a precision part and should be treated as one
A pin selectable reference with 1.24 V as its base is a bandgap, and a bandgap has a curvature that is trimmed at one temperature. The drift is therefore specified over a range rather than as a single coefficient, and a channel that measures at one temperature only is fine while a channel that spans a cabinet temperature range has to use the drift figure. The reference and the amplifier drift in the same direction on this part, which is the point of integrating them, but the two coefficients are not identical and the residual is what the specification has to cover.
Decoupling the reference output is worth a capacitor, and the value is set by the load steps rather than by stability. A bridge that is switched on and off presents a step to the reference, and the capacitor supplies the charge for the step. A 1 µF ceramic close to the pin is a reasonable start, and the settling time after a sleep cycle is the measurement that confirms it is enough.
Buying INA125P
The part is active in a 25 piece tube, which is a small carrier for a 16 pin DIP. A build of a few hundred boards needs a dozen tubes, and a board that carries two bridges needs two parts per board. The SO-16 siblings exist for a reflow line and carry the same die, so the package choice is the same process decision as elsewhere in this catalogue.
The reference accuracy should be confirmed against the customer's specification before the part is committed to a board, because the four taps are not all equally accurate and the 10 V tap on a 12 V supply has less headroom than the 2.5 V tap. Our medical device components page covers the bridge instrumentation we see in patient monitors, and the amplifier cross reference page lists the alternatives with an integrated reference.
Wiring a bridge to the part
A four wire bridge with separate excitation and sense leads is the arrangement that removes the lead resistance from the measurement, and the INA125 supports it because the reference has a sense connection. A two wire bridge shares the excitation and sense leads, which is simpler and puts the lead resistance in series with the bridge, and on a long cable that error is larger than the amplifier offset. The choice is a wiring decision that changes the accuracy more than the grade does.
The excitation leads should be twisted and kept away from the signal pair, because the bridge current times the lead inductance is a noise source, and the signal pair is at millivolts. A shielded cable with the shield driven from the reference rather than grounded is the standard arrangement for a transducer on a cable, and it costs one connection rather than a component.
Questions that arrive with this part number
Whether the reference can supply a 350 Ω bridge is the first question, and the answer depends on the excitation voltage: at 5 V the bridge draws 14 mA, which is more than the on chip reference will deliver, so a pass device is needed. Whether the part can run from a 3 V rail is the second, and it can, but the 2.5 V tap leaves little headroom and the 5 V tap is impossible. The third question is the sleep pin's effect on the reference, which settles more slowly than the amplifier and therefore sets the wake up delay.
The fourth is the pin count. A 16 pin footprint is not compatible with an eight pin amplifier, and a substitution in either direction is a board revision rather than a part swap.