Contact Us

DRV8350FHRTVR

Brand: Texas Instruments
Texas Instruments DRV8350FHRTVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

DRV8350FHRTVR — Power Management & Signal Chain | Superb Automation

DRV8350FHRTVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The DRV8350FHRTVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

DRV8350FHRTVR: the 100 V gate driver with functional safety documentation

The DRV8350FHRTVR is the F variant of the DRV8350, a 100 V three-phase gate driver for external N-channel FETs. The F is the difference that matters to a machine builder: this silicon is released as functional safety quality-managed, and the vendor supplies documentation to aid an IEC 61800-5-2 functional safety system. In practice that means a drive that has to be certified for a safe torque off function can point at a document set for the driver instead of treating it as an unqualified component.

Electrically it is the same 9 V to 100 V gate driver as the plain 8350. Peak gate current runs 50 mA to 1 A source and 100 mA to 2 A sink, set on the IDRIVE pin. The high side is biased by a doubler charge pump regulated to VDRAIN plus 10.5 V with 25 mA of average output, and the low side runs from a linear regulator that holds VGLS at 14.5 V and then 11 V at the gate outputs. Below 12 V of VM the pump runs in full doubler mode and produces twice VM minus 1.5 V unloaded, which is what keeps a 12 V system working at the bottom of its battery range.

The smart gate drive block is where most of the value sits. It watches the gate voltage and the drain voltage together, inserts a minimum dead time, and pulls the gate down hard if a dV/dt event tries to turn a FET back on. The slew rate is adjustable, which is how a drive trades switching loss against emissions without changing the FET or the board. A VDS comparator on each phase trips on overcurrent, and the threshold is one of seven values set by a resistor.

This member has no current sense amplifiers and no buck regulator. The 8353F adds the three amplifiers, and the R letter adds the 350 mA buck. The F itself is what a machine builder pays for when the end product needs a safety case rather than a data sheet.

Key data for the DRV8350FHRTVR

Operating range9 V to 100 V on VM, charge pump referenced to VDRAIN
OutputsThree half bridges for external N-channel FETs
Gate current50 mA to 1 A peak source, 100 mA to 2 A peak sink, 25 mA average
Gate suppliesVCP at VDRAIN plus 10.5 V, VGLS at 14.5 V, gate outputs at 11 V
SafetyFunctional safety quality-managed, documentation to aid IEC 61800-5-2 system work
PWM modes6x, 3x, 1x and independent inputs, 1x mode with an internal block commutation table for 120 degree sensored drive
ProtectionVM undervoltage, gate drive undervoltage, VDS overcurrent in seven steps, shoot through prevention, thermal warning and shutdown
Sleep current20 uA typical at VM of 48 V
Logic1.8 V, 3.3 V and 5.0 V CMOS inputs
Not fittedNo shunt amplifiers, no buck regulator on this variant

Body, packing and marking data

Body32-pin WQFN, the RTV outline, 5.00 mm by 5.00 mm, 0.75 mm maximum height
Carrier3000 pieces on a 330 mm large tape and reel
FinishNIPDAU lead finish, moisture level 2, 260 C peak reflow, one year floor life
TemperatureMinus 40 C to plus 125 C operating
Marking8350FH on the body, lot and date code on the reel label

Reading the code before you buy it

The string reads DRV8350 for the circuit, F for the functional safety release, H for the hardware interface, RTV for the 32-pin body, and R for the large reel. The FL and FS combinations exist as separate order codes: DRV8350FSRTVR is the same body with SPI instead of pins, and DRV8353FHRTAR is the 40-pin body with the three sense amplifiers. None of the F parts share a document with the non F parts, which is the first thing to check when a drawing quotes a revision.

That last point has a purchasing consequence. The plain DRV8350 document, revision SLVSDY6A, contains no row for any F order code, because the safety variants are published separately under SLVSFV1B. A buyer who searches the standard document for DRV8350FHRTVR finds nothing and may conclude the part does not exist. The way to confirm it is to open the F document and read the addendum, where the string is listed at 3000 pieces on a large reel with NIPDAU finish and level 2 moisture sensitivity.

The F suffix does not change the pinout, so a board built for DRV8350HRTVR accepts the F part. What changes is the paperwork: the safety documentation set is tied to the F order code, so a unit built with the non F part cannot claim the same safety case even though the die is described identically in the electrical tables.

Where the DRV8350FHRTVR fits

Servo drives, collaborative robot joints and automated guided vehicles are the applications where a functional safety argument has to be written, and where a 100 V rail is normal because the bus runs at 48 V or 60 V with room for regeneration. Linear motor transport systems use the same driver with a higher pole count, and there the adjustable slew rate is what keeps the cable emissions inside the limits a clean room demands.

Delivery drones and e-mobility platforms use the 100 V rating for the same margin reason, and the 1x PWM mode with an internal commutation table lets a small controller drive a sensored motor with one PWM line and three hall inputs. Our drone and UAV component page lists the surrounding parts that appear in those drive stages.

Because the FETs are external, the same driver covers a 200 W joint and a 3 kW traction stage. What changes is the FET, the gate resistor value and the copper. That scalability is the reason a machine builder standardises on one driver circuit and one safety document across a product family instead of qualifying a new integrated driver for every power level.

Questions we get on this code

Does functional safety quality-managed mean the part is certified? It means the vendor manages the development process to a functional safety standard and supplies documentation to support the system level case. The certification belongs to the machine, not to the driver, and a safety assessor will ask for the driver documents as an input rather than accept the part on its own.

What is the difference between F and non F on the bench? Nothing that a meter will show. Same body, same pins, same electrical limits. The difference is the document set and the order code, which is why a prototype can be built with either and only the production build has to match the safety file.

Can the 32-pin F part replace the 40-pin 8353F? No. The 40-pin RTA body carries the three sense amplifiers and their output pins, so the extra eight pins are function, not spare. A board that needs phase current measurement has to start from the 8353F.

Why 100 V when the bus is 48 V? Because a motor that is decelerated by the load pushes energy back into the bus, and a 48 V bus with a 60 V clamp still sees spikes that a 60 V driver cannot survive. The 100 V part is the margin, and it costs less than the field failure it prevents.

How do we verify incoming lots of a safety part? The marking and the reel label carry the F code, but the real check is the certificate of conformance matched to the order code, because a mixed reel of H and FH parts cannot be told apart by the package. Our incoming inspection plan page sets out the document trail that goes with that check.