Contact Us

DRV5057A4QDBZR

Brand: Texas Instruments
Texas Instruments DRV5057A4QDBZR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

DRV5057A4QDBZR — Power Management & Signal Chain | Superb Automation

DRV5057A4QDBZR

Texas Instruments — Power Management & Signal Chain

Product Overview

The DRV5057A4QDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

DRV5057A4QDBZR: linear position as a PWM duty cycle

The DRV5057A4QDBZR is a linear Hall sensor with a pulse width modulated output instead of an analog voltage. A 2 kHz clock leaves the package continuously, the duty cycle sits at 50 percent at zero field, and the duty moves with the applied field at 0.25 percent per mT on the A4 option. The A4 setting covers about 168 mT, the widest range in the family.

A PWM output solves a problem that analog Hall sensors have in industrial wiring: a voltage that has to travel 2 metres through a harness picks up noise and loses accuracy. A duty cycle carries the information in timing rather than in level, so a ground offset or a supply drop does not change the reading. The vendor states this directly as the reason the part exists.

The A4 option is the coarse end of the four sensitivities: A1 is 2 percent per mT over 21 mT, A2 is 1 percent over 42 mT, A3 is 0.5 percent over 84 mT and A4 is 0.25 percent over 168 mT. The A versions carry 0.12 percent per degree of magnet temperature compensation and the Z versions do not.

Key data for the DRV5057A4QDBZR

OutputPWM, open drain, 20 mA sink, 2 kHz carrier
Quiescent duty50 percent at zero field, 46 to 54 percent over the window
Sensitivity0.25 percent duty per mT at 5 V on the A4 option
Linear rangeAbout 168 mT, the widest in the family
Clamp behaviourDuty clamps near 6 percent and 94 percent beyond the linear range
Supply and current3.3 V or 5 V, 6 mA typical and 10 mA maximum
Power-on time0.9 ms to the first valid duty cycle

Body, packing and marking data

BodySOT-23, three pins, DBZ outline
Packing3000 pieces on a reel, printed as the ammo carrier on the active row
FinishTin lead finish, moisture level 2 at 260 C, one year floor life
Marking57A4 on the body, which identifies the A4 die

Reading a duty cycle in a controller

The receiving side needs a timer rather than an ADC. Measure the high time and the period, divide, and the result is the field. A capture input on a microcontroller does this in hardware, and a 2 kHz carrier leaves plenty of time for the arithmetic, which is why the part suits a small controller without an analogue front end.

The open drain output needs a pull up, and the value sets the rise time against the cable capacitance. A 4.7 k resistor into a 100 pF cable is fast enough for a 2 kHz carrier; a 100 k resistor into the same cable is not, and the duty cycle will appear to wander as the edges round off.

The clamp behaviour is worth knowing. Beyond the linear range the duty stops at about 6 percent and 94 percent rather than at 0 and 100 percent, which allows a controller to detect saturation as distinct from a missing signal. A pulse train that disappears entirely means the supply or the pull up, not an over-range field.

Where a PWM sensor is the better choice

Position sensing on a machine with a long harness, height and tilt measurement, fluid flow and game controller axes all appear on the vendor list. The common thread is distance between the sensor and the controller, or an environment where an analog level is hard to keep clean.

For a board that is moving from an analog sensor to a PWM one, the how to verify a drop in replacement page covers the interface change, and the medical device components page is worth reading where the mechanism is a pump or a valve in a clinical product.

Questions we get on this code

Can the PWM output be read by an ADC instead of a timer? It can, with a low pass filter and a long averaging window, but the result is slower and less accurate than a capture timer. The whole advantage of the part is lost if the duty is converted back to a voltage at the receiving end.

What happens if the sensor is unpowered? The open drain output goes high impedance and the pull up takes the line to the rail, which a capture timer reads as a permanent 100 percent duty. That is a distinguishable fault, and it is one of the reasons the open drain output is preferred over a push-pull one on a long cable.

The last question is resolution. At 0.25 percent per mT and a 168 mT range, a 16 bit timer on a 2 kHz carrier resolves about 0.005 percent of duty, which is 0.02 mT. In practice the noise on the edges limits it long before the timer does.