DRV5055A1QDBZ

Brand: Texas Instruments
Texas Instruments DRV5055A1QDBZ is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

DRV5055A1QDBZ — Power Management & Signal Chain | Superb Automation

DRV5055A1QDBZ

Texas Instruments — Power Management & Signal Chain

Product Overview

The DRV5055A1QDBZ from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

DRV5055A1QDBZ: a ratiometric linear Hall sensor at 100 mV per mT

The DRV5055A1QDBZ is a ratiometric linear Hall sensor in the SOT-23 body, with the A1 sensitivity of 100 mV per mT and a quiescent output at half the supply. Ratiometric means the output is measured against the same rail that feeds the sensor, so a 5 percent supply change moves the offset and the gain together and the ADC, referenced to the same rail, does not see it.

The A1 option is the most sensitive of the DRV5055 group, with a linear range of about plus or minus 21 mT at 5 V. Sensitivity is specified as 95 to 105 mV per mT at 5 V, and 57 to 63 mV per mT at 3.3 V, so the same part reads about 60 percent of the sensitivity on a 3.3 V rail. The A versions also carry magnet temperature compensation at 0.12 percent per degree, which counteracts the loss of field as a ferrite magnet warms.

The part senses flux perpendicular to the top of the package, runs from a 3.3 V or 5 V supply, and has a 20 kHz sensing bandwidth, which is high enough to see a fast mechanical event and low enough to keep the output noise manageable.

Key data for the DRV5055A1QDBZ

OutputAnalog, ratiometric, quiescent at half the supply
Sensitivity at 5 V100 mV per mT typical, 95 to 105 mV per mT over the window
Sensitivity at 3.3 V60 mV per mT typical, 57 to 63 mV per mT
Linear rangePlus or minus 21 mT at 5 V
Quiescent voltage2.5 V typical at 5 V, 2.43 to 2.57 V over the window
Bandwidth20 kHz sensing bandwidth
Supply and current3.3 V or 5 V, 3 mA typical at 5 V and 2 mA at 3.3 V

Body, packing and marking data

BodySOT-23, three pins, DBZ outline
PackingNo reel letter on this string, so the packing is not the published 3000 piece row
FinishTin lead finish, moisture level 2 with a one year floor life on the reel rows
Marking55A1 on the body, which identifies the A1 die

The missing letter at the end of the string

The code reads DRV5055, A1 sensitivity, Q temperature, DBZ body, and then stops. On this family the last letter is the packing: R is the 3000 piece large reel, T is the 250 piece reel, and no letter is a bulk bag. The addendum prints DRV5055A1QDBZR and DRV5055A1QDBZT as active rows and does not print a bare DRV5055A1QDBZ row.

That matters at order time rather than at engineering time. A bill of materials with the bare string will be quoted against a reel row by one distributor and against a bag by another, and the two are not the same article for a pick and place line. The safe habit is to add the packing letter explicitly, and to state the reel size on the purchase order.

The second point is the A versus Z split. A1 is temperature compensated, so the sensitivity rises about 0.12 percent per degree to offset a magnet that weakens as it warms. Z1 has the same sensitivity and the same range but no compensation, and the two are otherwise identical, which is why the letters are easy to confuse on a drawing.

Where the A1 sensitivity fits

Valve and damper position, joystick and trigger travel, and any mechanism with 10 to 20 mT of swing are the natural fits for 100 mV per mT. The ratiometric output also suits a controller whose ADC reference is the same 5 V rail, because the supply tolerance cancels in the reading.

For a program moving from an older linear sensor, the how to verify a drop in replacement page sets out the sensitivity and offset checks, and the IMU selection guide explains where a linear Hall part still beats an inertial sensor for absolute position.

Questions we get on this code

Why does the sensitivity change with the supply? Because the part is ratiometric: the internal gain is tied to the rail, so a 3.3 V part delivers roughly 60 percent of the 5 V figure. That is a feature on a ratiometric system and a trap on a system that assumes a fixed mV per mT number.

What about the quiescent tolerance? The 2.43 V to 2.57 V window is 2.8 percent, which is wider than the sensitivity window and dominates the offset error at zero field. A controller that calibrates the zero position at start up removes most of it, and one that trusts the nominal 2.5 V carries the full error into the position reading.

A third point is the output loading. The output stage drives a defined load, and a long cable with a large capacitance will slow the 20 kHz bandwidth that the part advertises. On a bench test the signal looks clean, and on the machine the same signal has a rounded edge that the controller samples at the wrong moment. Terminate or buffer at the receiving end rather than trusting the data sheet figure over an unknown load.