DRV401AIRGWR
Product Specifications
DRV401AIRGWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV401AIRGWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV401AIRGWR: The Signal Conditioner for a Fluxgate Current Sensor, Not a Standalone Driver
DRV401AIRGWR is a signal conditioner and coil driver for Vacuumschmelze fluxgate current probes in a VQFN (RGW) body of 20 pins. It excites a fluxgate probe, amplifies the probe signal with a 4 V per V differential stage that has a 0.1 mV offset, closes a compensation loop through an H bridge that can source and sink 75 mA, and outputs a voltage proportional to the primary current. It also demagnetises the core at power up and on command, which is what keeps a 1000 A sensor accurate after a fault current has pushed the core into saturation.
Order code and package
| Ordering string | DRV401AIRGWR, large reel, 3000 pieces |
| Family document | DRV401, SBVS070B, revised May 2009 |
| Package | VQFN (RGW), 20 pins, exposed pad |
| Lead finish | NIPDAU |
| Moisture level | Level 2, 260 C, one year floor life |
| Body marking | HAAQ |
| Temperature range | minus 40 to plus 125 degrees |
| Obsolete row in the family | DRV401AIDWP in SO PowerPAD, marked obsolete on the addendum |
| Active SO row | DRV401AIDWPR, 1000 piece reel, same die in a wider body |
| Supply | 5 V single rail, 7 V absolute maximum |
Electrical parameters that decide the application
| Supply range | 5 V nominal, 7 V absolute maximum |
| Differential amplifier gain | 4 V per V, gain error 0.3% maximum |
| Amplifier offset | 0.1 mV maximum, drift 1 uV per C |
| Amplifier bandwidth | 2 MHz, slew rate 6.5 V per us |
| Input resistance | 20 kOhm differential, 50 kOhm common mode |
| Output noise density | 170 nV per root Hz at 1 kHz |
| Compensation coil drive | H bridge, 75 mA on the probe pins and 25 mA elsewhere |
| Probe loop frequency | 250 kHz minimum, half cycle 280 ns typical |
| Probe comparator threshold | 22 to 34 mA, 28 mA typical |
| Probe pin resistors | 47 to 71 Ohm to the supply, 60 to 90 Ohm to ground |
| Signal output range | 48 mV from either rail at 2.5 mA, with an over range flag |
| Voltage reference | 2.5 V typical for the output stage |
| Degauss | at power up and on demand, 106 ms cycle |
| Junction to ambient | the QFN body with a soldered pad is the thermal path |
Family variants and how they differ
| DRV401 | The device on this page, for VAC fluxgate probes |
| DRV401A | The current letter, with the same function and a wider temperature window |
| DRV411 | A later conditioner for the same class of probe with a different loop topology |
| What it is not | Not a current sense amplifier, it needs the probe to close the loop |
| Probe family | Vacuumschmelze cores from a few amps to several thousand amps |
| Drive option | External high power drivers can replace the internal H bridge for large coils |
Points to check before this part goes on a BOM
A fluxgate sensor is not a shunt. The probe is a saturable core driven into both polarities at 250 kHz, and the second harmonic of the probe signal is proportional to the field the primary current produces. The DRV401 does three things: it excites the probe through IS1 and IS2, it amplifies the difference with a 4 V per V stage, and it drives a compensation winding so the core stays at zero flux. The output is the compensation current, which means the measurement does not depend on the core linearity.
The 0.1 mV offset of the differential stage is what makes a 1000 A sensor possible. With a 4 V per V gain, an offset of 1 mV at the input appears as 4 mV at the output, and in a closed loop that becomes a fixed current error. The same arithmetic applies to the drift, which is 1 uV per C, so a 100 C swing moves the output by 0.4 mV, well inside the resolution of a 12 bit converter on a 2.5 V reference.
Degaussing is not a convenience. A fault current of several thousand amps drives the core into saturation and the loop cannot recover the residual flux by itself, so the part runs a demagnetisation cycle of about 106 ms at power up and whenever the controller asks. During that cycle the output is not valid, and a system that samples the sensor continuously has to ignore the period or hold the last value.
The internal H bridge is limited to 75 mA on the probe pins and the loop resistor values are chosen for a probe of a few ohms. A large core with more turns and more resistance needs an external driver, and the part supports that by bringing the comparator output out. That is the route a 2000 A sensor takes, and the internal bridge then only drives a small signal.
What a board has to get right
The probe wiring is the sensitive node. IS1 and IS2 carry a square wave at 250 kHz and the differential amplifier measures a signal in the microvolt range, so the probe leads have to be short, symmetric and away from the compensation winding. The internal resistors of 47 to 71 Ohm and 60 to 90 Ohm are matched to 1500 ppm, and any external asymmetry adds directly to the offset.
The output stage drives 2.5 mA into a load and swings to within 48 mV of either rail, with an over range flag that asserts 2.5 to 3.5 us after a 1 V step. A converter that expects a full rail to rail swing loses the top and bottom of its range; a converter that watches the flag knows when the reading is out of bounds and can report a fault instead of a number.
The compensation winding is where the accuracy is finally decided. The loop drives current into a coil wound around the core until the flux returns to zero, and the output voltage is measured across a resistor in that loop. The resistor tolerance and its temperature drift enter the reading directly, so a 0.1 percent part with 25 ppm per C costs less than the error it removes. The loop is stable with a coil of a few ohms and becomes slow with a coil of a hundred, which is when the external driver and a different compensation network come in.
Decoupling on this part is not cosmetic. The H bridge switches the full coil current at 250 kHz and the differential stage resolves microvolts at the same time, so a supply that dips on every edge appears as a signal on the output. A 10 uF ceramic and a 100 nF part at the supply pins, with the probe return taken straight to the ground pin, keeps the switching current out of the measurement path. The exposed pad carries the heat, and it also has to be the quietest point on the board.
Where this order code fits
Current sensor builders usually arrive from the analogue cross reference side, and replacement enquiries start from the obsolete part page Teams comparing it with a neighbouring part start from our Amplifier Cross Reference page, and teams replacing a part that has gone end of life start from the Obsolete RF Part Replacement page.
Questions buyers ask
Can this part be used without a VAC probe? No. The loop is tuned for a specific core and excitation frequency, and the internal timing assumes the probe saturates within the 280 ns half cycle window. A different core needs a different excitation scheme, which is what the DRV411 and its register set exist for.
What sets the current range of the sensor? The number of primary turns, the compensation winding and the value of the loop resistor. The part sets the accuracy of the loop, not the range, and the same die serves a 50 A sensor and a 2000 A sensor with different coils and a different external driver.
Is the SO package still available? The plain DRV401AIDWP row is obsolete, while DRV401AIDWPR on a 1000 piece reel and the QFN body on this page are both active. A board that needs the wider body for thermal reasons should move to the reel row rather than plan a last time buy.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.