Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ40Z80RSMR: two to six series pack manager with impedance tracking in a thirty two pin VQFN
BQ40Z80RSMR is a pack manager that combines gas gauging, protection and authentication for two to six series cells in one device in a VQFN body of 32 pins. The part runs Impedance Track gauging against a cell model it learns in the field, drives high side N channel protection FETs, and answers the host over an SMBus v1.1 interface. It handles packs up to 29 Ah natively and larger packs through a scaling factor.
Order code and package
| BQ40Z80RSMR | VQFN RSM, 32 pins, 3000 pieces on a large reel, marking BQ40Z80 |
| BQ40Z80RSMT | same body, 250 pieces on a small reel, marking BQ40Z80 |
| BQ40Z80RSMTG4 | same body and small reel, G4 material code |
| Moisture level | Level 1, 260 C, unlimited floor life on every published row |
| Temperature | minus 40 to plus 85 C ambient on every published row |
| Supply | 2.2 V to 32 V at the pack and supply pins, with the part powered from the cells it manages |
| Interface | SMBus v1.1 two wire, the bus a smart battery system expects |
Electrical parameters that decide the application
| Cell range | 2 series to 6 series Li-ion or Li-polymer cells |
| Shutdown voltage | 1.8 V minimum, 2.0 V typical and 2.2 V maximum at the pack pin |
| Start up voltage | 2.05 V minimum, 2.25 V typical and 2.45 V maximum, always above the shutdown point |
| Hysteresis | 250 mV between shutdown and start up, which keeps a pack from oscillating at the end of discharge |
| Sense inputs | SRP and SRN accept plus or minus 200 mV across the sense resistor |
| Capacity | 29 Ah supported natively, larger packs through scaling keys |
| Authentication | elliptic curve cryptography or SHA-1, with secure memory for the keys |
| Multifunction pins | eight pins configurable as thermistor inputs, ADC inputs, GPIO, LED drives or a display button |
Family variants and how they differ
| Gauging | Impedance Track, which learns the cell resistance and capacity from the load profile in the field |
| Protection | voltage, current, temperature, charge timeout and FET failure, all programmable |
| Balancing | internal cell balancing that runs while charging or at rest |
| Protection FETs | high side N channel drive, so the pack return stays intact |
| Authentication | ECC or SHA-1 selected at configuration, with the key held in secure memory |
| Host features | TURBO Mode 2.0 and Intel dynamic battery power technology, reporting available peak power to the host |
Points to check before this part goes on a BOM
Gauging accuracy depends on the learning cycle, not on the first power up. Impedance Track builds its model from a full charge and a partial discharge with a rest, so a pack that is only ever topped up in a dock will keep the factory default model and drift. A product that ships with a gauge has to schedule one full cycle during production test.
The start up and shutdown window is wider than the cell chemistry window. A two series pack at 2.05 V per cell pair is already deep in the discharge knee, so the device survives a pack that has been left flat, but the cells may not. The 250 mV of hysteresis is what stops the gauge from cycling on and off while the protection FET is open.
The high side drive is the reason this part suits a metal enclosure. With the FETs in the positive path, the pack return stays at the same potential as the chassis, so a single insulation fault does not put the full stack voltage on the case. That is the requirement that pushes medical and telecom packs to high side protection in the first place.
Authentication has to be provisioned before the pack leaves the line. The key is written into secure memory once, and a pack shipped with the default key is a pack whose clone will pass. The provisioning step belongs in the same fixture as the gauge learning, because both need the pack powered and the bus open.
The eight multifunction pins are the part of the configuration that gets changed late. A pin used as a thermistor input cannot also drive an LED, and the change is a register write rather than a board change. That flexibility is useful, and it also means two builds of the same board can have different pin maps, so the configuration file has to be versioned with the firmware.
A pack that has latched off needs a deliberate recovery path. The device can be configured to recover on its own or to stay latched, and the choice changes what the end product does after an over current event. In a tool, recovery is wanted. In a medical pack, a latched fault with a logged reason is wanted.
What a pack integrator has to write down
Three things travel with the pack: the chemistry, the cell model and the protection thresholds. Change any one and the gauge has to relearn, the thresholds have to be rechecked against the new cell datasheet, and the configuration file needs a new version. A pack built with a dropped in cell from a second source is a pack with a new model.
The second item is the sense resistor. The gauge is calibrated against the actual shunt, so a build that changes the shunt value without changing the configuration reports current that is wrong by the ratio of the two values, and every derived figure follows it.
Where field returns come from
The most common return is a pack that reports a sudden drop from 20 per cent to empty. That is a gauge whose learned resistance no longer matches the cells, usually after a cell change or a long storage at high temperature.
The second is a pack that will not charge after a deep discharge. The protection FET is open and the charger sees no pack, and the recovery path needs the charger to present a voltage the device will accept before it closes the FET again. Whether that happens automatically is a configuration choice made at build time.
Where this order code fits
Battery packs for medical carts and infusion pumps, telecom backup units, cordless power tools, e-bikes, and portable test equipment. The common thread is a pack that has to report its remaining capacity honestly and that has to refuse a counterfeit replacement. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
Does the gauge need a full discharge to be accurate? It needs one full charge and one meaningful discharge with a rest, which the production line can do in a few hours. After that the model updates as the product is used, so a device that only ever runs between 40 and 60 per cent will keep a usable but less precise model.
What happens if the pack is left connected with the host asleep? The device drops into a low power state and keeps the gauging data, and the shutdown threshold at 1.8 V protects the cells from being drained by the gauge itself. The host has to wake the bus before it reads capacity, which costs one bus cycle.
Can the protection FETs be in the low side instead? The drive is for high side N channel FETs, so a low side arrangement does not use the device as intended and loses the benefit of an intact return path. If low side is required, the pack should use a separate protector.
Is the same part usable without authentication? Yes. Authentication is configured, not hard wired, so a pack that does not need it simply leaves the keys unwritten. The secure memory and the crypto block are still there, and the configuration file records whether they were used.
Why does the capacity figure matter at 29 Ah? The gauge scales its internal counters to the cell capacity, and 29 Ah is the largest pack it covers without a scaling key. Beyond that the key changes the resolution, so a 40 Ah pack reports in coarser steps.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.