BQ296227DSGR
Product Specifications
BQ296227DSGR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ296227DSGR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ296227DSGR: an overvoltage protector that also powers the always on circuit
The BQ296227DSGR is an overvoltage protector for a 2, 3 or 4 series pack that carries a regulated output alongside the protection. The regulator delivers up to 2 mA at 3.3 V on this code, which is enough to run a real time clock oscillator or a small always on circuit straight from the pack, and it shuts itself down when a cell crosses the trip point. That combination is what makes it useful in a pack that has to keep a clock alive for years without a separate housekeeping rail.
The protection side is a fixed 4.55 V trip with a 6.5 second delay, an undervoltage threshold of 2.5 V, an accuracy of plus or minus 10 mV and a supply current of about 4 microamps. Each cell is monitored independently, and the output drives an external FET or a fuse driver. The body is an 8 pin WSON.
The self disable behaviour is the part that a pack specification has to spell out. When any cell goes over the trip point, the regulated output turns off, which removes the load that is holding the pack up and lets the protection act on a pack that is no longer being asked to deliver current.
Key data for the BQ296227DSGR
| Function | Overvoltage protection with a regulated output for always on circuits |
| Cell count | 2, 3 or 4 series, one input per cell |
| Overvoltage threshold | 4.55 V fixed |
| Overvoltage delay | 6.5 seconds fixed |
| Undervoltage threshold | 2.5 V |
| Threshold accuracy | Plus or minus 10 mV |
| Regulated output | 3.3 V on this code, up to 2 mA, with a ceramic output capacitor |
| Self disable | Regulator turns off when any cell exceeds the trip point |
| Supply current | About 4 microamps |
| Package | WSON, 8 pins, DSG body |
| Temperature | Minus 40 to 110 C |
| Ordering | 3000 pieces on a large tape and reel, 250 on a small reel, marking 6226 |
Decoding the option table before you order
The BQ2962 family prints its options as a table of trip point, delay, undervoltage threshold and regulator voltage, with several part numbers sharing a row. On this code the table gives 4.55 V, 6.5 seconds, 2.5 V and 3.3 V. The neighbouring codes differ in the regulator voltage, 3.0 V or 3.15 V, and in the undervoltage threshold, 2.8 V on one row. A purchase order that names BQ2962 without the four digits will be filled with whichever option the distributor holds, and a 3.0 V regulator in place of a 3.3 V part is a clock that stops.
The cell count is set by how many sense inputs are used. On a 2 series build the upper inputs are tied to the top of the stack, following the note in the document that an unused input is shorted to the one below it. Leaving an input open on this family reads as an overvoltage and turns the regulator off at first power up.
What 2 milliamps of regulated output actually buys
A real time clock oscillator draws a few microamps, and a small supervisor or a wake circuit draws tens. Two milliamps of headroom covers those with room to spare, and it covers them from the pack rather than from a coin cell. On a product that has to keep time while the main processor is off, that removes a battery, a holder and the service life limit that comes with it.
The regulator needs a ceramic capacitor on its output for stability, and the value matters. Below the recommended value the loop can oscillate, and an oscillating regulator on an always on rail is a slow drain that looks like a leaking cell. The capacitor should be a stable dielectric, because the effective value of a high K ceramic falls with voltage and temperature.
The 4 microamp supply current is the figure for the protection side with the regulator unloaded. Add the load current to get the pack drain, and check the total against the shelf life the product claims. A pack that is expected to sit for two years before first use has a budget of a few microamps in total, not a few microamps plus a clock.
Where it fits in a build
This is a part for packs that keep something alive: meters, asset trackers, medical devices with a clock, and instruments that have to log time while off. The 110 C rating also makes it usable next to a warm power stage. It is not a gauge, and a pack that has to report capacity needs a gauge on the same board.
For a build that carries this part along with a gauge, a charger and the pack connector, the kitting service page covers how we kit the line so the pack does not stop for one missing reel.
The sourcing side of this part is covered on the one stop BOM sourcing. For a pack that carries a protector, a gauge and a connector on one BOM, that page covers how we kit the line as one release.
Questions we get on this code
Can the regulated output run a microcontroller in sleep mode? Two milliamps is enough for a small part in a low power state, not for a processor that wakes and transmits. Size the load against the 2 mA figure and add the regulator quiescent current.
Does the regulator recover after the fault clears? It turns back on when every cell falls below the trip point minus the hysteresis. In a fuse arrangement the fuse is open, so the pack is already out of service.
Why is the undervoltage threshold on the same die as the overvoltage trip? Both are cell level protections and both use the same sense inputs. The undervoltage threshold does not switch the regulator on this part, it is a separate output condition.
Is the 6.5 second delay too slow for a fast charger? The delay is there to ignore charger transients. A cell that is genuinely running away stays above the trip point for far longer than 6.5 seconds, and a transient does not.