Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ27421YZFR-G1A: a single cell gauge with the sense resistor on the die
The BQ27421YZFR-G1A is a system side fuel gauge for one Li-ion cell. It sits on the main board rather than inside the pack, reads the pack through two connections, and reports remaining capacity in mAh, state of charge in per cent and battery voltage in mV over a 400 kHz I2C bus. The Impedance Track algorithm behind those numbers adjusts for ageing, self discharge, temperature and rate, so the reported state of charge holds up as the pack loses capacity.
What makes this member interesting is the sense element. Most gauges need a shunt on the board, a kelvin pair and a calibration step. The BQ27421-G1 integrates a 7 milliohm sense resistor into the die, which removes the shunt, its two traces and the tolerance that comes with them. The document states the part needs connections only to PACK+ and PACK minus for gauging, and that is the whole current path. For a handheld or a wearable where the pack sits a few millimetres from the processor, that removes the largest source of coulomb counting error on a small board.
The body is a 9 ball chip scale package at 1.62 mm by 1.58 mm with 0.5 mm pitch. It runs from the battery through an internal regulator, so there is no separate rail to sequence, and it reports an internal die temperature or accepts a host reported temperature when the thermistor sits elsewhere.
Key data for the BQ27421YZFR-G1A
| Function | System side fuel gauge for one Li-ion cell, Impedance Track algorithm |
| Sense element | 7 milliohm resistor integrated on the die, no external shunt |
| Reports | Remaining capacity in mAh, state of charge in per cent, voltage in mV, state of health |
| Voltage measurement | BAT pin range 2.45 V to 4.5 V, 125 ms conversion, 15 bit effective resolution |
| Interface | I2C at 400 kHz, standard command set, configurable state of charge interrupt |
| Normal current | 93 microamps typical with the load above the sleep threshold |
| Sleep and hibernate | 21 microamps in sleep, 9 microamps in hibernate |
| Shutdown | 0.6 microamps in host commanded shutdown, regulator output disabled |
| Chemistry codes | 0x128 for 4.2 V cells, 0x312 for 4.3 V to 4.35 V, 0x3142 for 4.3 V to 4.4 V |
| Package | DSBGA, 9 balls, 1.62 mm by 1.58 mm, 0.5 mm pitch |
| Temperature | Minus 40 to 85 C operating |
| Ordering | 3000 pieces on a large tape and reel, moisture level 1 at 260 C, no floor life limit |
The three chemistry codes, and why the suffix decides the build
The G1A row carries chemistry identifier 0x128 and is set up for a cell that charges to 4.2 V. The G1B row carries 0x312 for a cell that charges to 4.3 V or 4.35 V, and the G1D row carries 0x3142 for a cell between 4.3 V and 4.4 V. The three parts share a body, a pinout and a package, and the marking on the top of the die reads BQ27421 on all of them, so a reel that has lost its label cannot be told apart by looking at the part.
That matters because the chemistry identifier sets the table the gauge uses for open circuit voltage against state of charge. Fit a 4.35 V cell and leave the 4.2 V identifier in place, and the gauge stops charging at the wrong point and reports the pack as full while a slice of capacity is still unused. The error looks like a pack that has aged early. It is a configuration mistake, and no amount of learning cycles will correct it, because the algorithm is comparing the cell against the wrong table.
Ask for the row when you order, not the family name. A purchase order that names BQ27421YZFR without the suffix will be filled with whichever row the distributor holds, and the difference only shows up at the end of a charge cycle on the bench.
What Impedance Track needs from the pack
The algorithm works from two things: an accurate open circuit voltage reading when the cell is at rest, and a model of how the internal resistance changes with state of charge and temperature. It does not need a full discharge cycle to start reporting, which is the practical advantage over coulomb counting. A pack that has been sitting on a shelf for a month still comes up with a usable state of charge after the first relaxation, because the gauge is reading the cell rather than counting electrons from an unknown starting point.
The relaxation matters. A gauge that is asked for a state of charge reading two seconds after a 2 A pulse will answer from the model and the last known point, not from a settled voltage, and the answer will be a little off. The smoothing filter in the part exists for exactly this reason, and it is why a reading taken at idle is more trustworthy than one taken under load.
Temperature is the other input. With no thermistor connected the gauge uses its own die temperature, which tracks the board rather than the cell. On a product where the pack sits against a processor that runs warm, the die reads high and the model predicts a higher internal resistance than the cell actually has. Wire the pack thermistor where the document shows it and the reading follows the cell.
Where it fits in a build
This is a gauge for a product with one cell, a processor that can spare 90 microamps, and a pack that may or may not be removable. Medical handhelds, portable instruments, asset tags with a rechargeable cell and consumer devices with a small battery all fit that description. What does not fit is a two cell pack, or a product where the gauge has to sit inside the pack on the cell flex, because the integrated sense resistor assumes the current path passes the board.
For a programme that is already running this code and needs the reel split across two build dates, the date code management page sets out how we track reel age and what we will not ship into a new production run.
The sourcing side of this part is covered on the component lead time solutions. For a gauge that is quoted late in a programme, that page sets out the stock, date code and packaging checks we run before a date is promised.
Questions we get on this code
Does the gauge need a calibration step in production? No. The sense resistor is inside the die, so there is no shunt tolerance to trim and no current calibration register to load. What the line does need is the correct chemistry identifier written once, and that can be part of the same programming step that loads the pack parameters.
Can it report state of health on a pack with no cycle history? Yes, but the first estimate is a starting point rather than a measurement. The gauge improves the figure as it sees charge and discharge cycles, so a brand new pack reports a value close to 100 per cent until there is evidence to the contrary.
What happens if the pack is removed and refitted while the board is powered? The gauge keeps its learned values in volatile memory and loses them if its own supply drops. On a removable pack that means a short re learning period after each swap, which is why the document describes the part as suited to both embedded and removable batteries rather than treating them as the same case.
Is the 93 microamp figure the number to use for a battery life budget? Use it as the normal mode figure and add the sleep and hibernate numbers separately. A product that spends most of its life with the load below the sleep threshold sits nearer 21 microamps, and a product in a shipping mode sits at the shutdown number.