BQ25101YFPR
Product Specifications
BQ25101YFPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ25101YFPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ25101: a 250 mA linear charger for the smallest packs
The BQ25101YFPR charges a single Li-ion or Li-polymer cell at up to 250 mA from an input rated to 30 V, with a 6.5 V overvoltage cut off and a 6 ball chip scale body. It is built for products where the pack is small: a wearable, a sensor node, a disposable style medical patch, a headset.
Two figures describe why this part is chosen instead of a generic linear charger. The first is the termination current, which is settable down to 1 mA. A charger that terminates at 10 per cent of a 250 mA fast charge current stops at 25 mA, and on a 40 mAh pack that leaves a real amount of capacity unused every cycle. The second is the battery output leakage, a maximum of 75 nA. On a product that sits in a drawer for a year, that figure decides whether the pack is still alive when it is taken out.
The charge profile is the standard three phase one: conditioning, constant current, constant voltage, with the termination threshold set by a resistor. A ten hour safety timer backs it up.
Key data for the BQ25101YFPR
| Function | Single cell Li-ion and Li-polymer linear charger |
| Charge current | 10 mA to 250 mA, set by a resistor |
| Current accuracy | 10 per cent charge current |
| Voltage accuracy | 1 per cent charge voltage |
| Termination | Adjustable, minimum 1 mA |
| Battery leakage | 75 nA maximum with the input removed |
| Input rating | 30 V rating, 6.5 V input overvoltage protection |
| Chemistry options | 4.35 V on the H variants, 4.30 V on the A variant, 4.2 V on the base |
| Thermal | Regulation at 125 C junction, shutdown at 150 C |
| Package | DSBGA, 6 balls, YFP body |
| Temperature | Minus 40 to 85 C operating |
Body and ordering data
Six strings share the document: bq25100, bq25101, bq25100A, bq25100H, bq25101H and bq25100L. They differ in the regulation voltage and in the presence of the status output, not in the charge engine. The orderable row on this page is BQ25101YFPR, DSBGA YFP with 6 balls, 3000 pieces on a large tape and reel, SNAGCU finish, moisture level 1 at 260 C with no floor life limit, minus 40 to 85 C, marking 25101.
A 6 ball body at 1.6 mm by 0.9 mm class size is smaller than the passive parts around it. The reel is where the cost sits, and a line that runs small batches should take the 250 piece row rather than open a 3000 piece reel for a hundred units.
The 4.35 V variants and the cell they belong to
A cell specified for 4.35 V holds about 8 per cent more capacity than the same cell specified for 4.2 V, and the charger has to match the cell rather than the other way round. Charging a 4.2 V cell to 4.35 V shortens its life and, at the top of the temperature range, is a safety issue. Charging a 4.35 V cell at 4.2 V is safe and simply leaves capacity unused.
The three voltage options exist because the same die is sold into three different pack specifications. When a product changes cell vendor, the charger string may have to change with it, and that is the change that gets missed between a pack qualification and a production release.
Where it fits in a build
Headsets, wearables, sensor nodes, small medical patches and any product with a pack under 200 mAh. The 75 nA leakage is what makes it usable in a product that is stored for a long time between uses. The medical device components page covers the traceability and packaging questions that come with the patch and monitor market.
For a pack above 500 mAh, 250 mA of charge current is a two hour charge at best and the part is the wrong size. Move to a 1 A part with a power path.
The sourcing side of this part is covered on the date code management. For a small pack built in short runs, that page covers how we handle reel splits and date codes so a two year old charger does not reach a new build.
Questions we get on this code
Can it charge from a 12 V source? The input survives 30 V and the protection cuts at 6.5 V, so a 12 V source is disconnected rather than used. The 30 V figure is a survival rating.
What happens when the battery is missing? The output regulates at the charge voltage and the current falls to the termination level. There is no power path on this part, so a system load in parallel with the pack has to leave enough current for the pack to reach termination within the ten hour timer.
Is 1 mA termination real? It is the minimum the resistor can be set to, and it is accurate enough for a small pack. On a 40 mAh cell, 1 mA is 2.5 per cent of capacity, which is close to the self discharge of the cell itself.
How much does the thermal loop cost me? At 250 mA from 5 V into a 3.7 V cell the dissipation is only about 0.3 W, so the loop rarely acts. It acts on a 9 V source or in a sealed enclosure.