The BQ24616RGER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ24616RGER standalone switch mode charger controller with JEITA support
The BQ24616RGER is a standalone synchronous buck charge controller for one to six series lithium cells, with a system power selector and JEITA compliant temperature behaviour. It drives external N-channel FETs at 600 kHz, regulates charge voltage to plus or minus 0.5 percent and charge and adapter current to plus or minus 3 percent, and runs from a 5 V to 28 V adapter. Up to 10 A of charge current is available with the right FETs and inductor.
This is a controller, not an integrated charger, and that is deliberate. Packs from one to six cells and charge currents up to 10 A do not fit inside one package, so the power stage is external and the part owns the control loop, the protection and the power path. The JEITA behaviour means the charge voltage and current step down as the pack temperature leaves the comfortable window, which is what medical and industrial customers ask for when a pack may be charged in an uncontrolled room.
Key parameters taken from the BQ24616RGER document
| Function | standalone synchronous buck charge controller, 1 to 6 cells |
| Package | RGE, 24 pin VQFN, 4.00 mm by 4.00 mm |
| Adapter input range | 5 V to 28 V |
| Switching frequency | 600 kHz |
| Charge current | up to 10 A, plus or minus 3 percent |
| Charge voltage accuracy | plus or minus 0.5 percent over minus 40 C to 125 C |
| Adapter current accuracy | plus or minus 3 percent |
| Reference output | 3.3 V on the VREF pin, 1 uF ceramic |
| Charge voltage on the feedback pin | 2.1 V in the warm temperature window |
| Power path | automatic adapter or battery selection with a reverse protection input FET |
| Sleep comparator | 40 mV to 150 mV, 100 mV typical, with 15 nA of sleep current |
| Gate drive | 6 V, 30 ns dead time, up to 99.5 percent effective duty |
| Safety | input overvoltage, battery detection, programmable safety timer, charge overcurrent, battery short, battery overvoltage, thermal shutdown |
The table above is read from the vendor document rather than from a catalogue summary. Where the document prints a minimum and a maximum, both are kept, because the number a test station should use is the limit and not the typical.
Where the numbers matter in a real build
The feedback voltage is 2.1 V, not the 0.6 V that most buck converters use. A divider copied from a 0.6 V reference part gives a charge voltage three and a half times too high, and the pack will be destroyed on the first charge. The 2.1 V reference is high on purpose: it keeps the divider current low enough for a battery powered product to leave the divider connected, and it reduces the error contribution of the divider itself.
The three current set pins are separate for a reason. ISET1 sets the fast charge current, ISET2 sets both the precharge current and the termination threshold, and ACSET sets the adapter current limit. The vendor requires the fast charge current to be at least twice the termination current, otherwise the charger terminates early and the pack never reaches full capacity. That rule is easy to break when the charge current is reduced for a smaller adapter without changing ISET2.
The JEITA behaviour works from the thermistor divider on the TS pin. As the pack temperature moves out of the comfortable window, the part reduces the charge voltage first and then the current, and it stops charging outside the allowed window. For a product charged in a warehouse or a vehicle, this is the difference between a pack that lasts its rated cycles and one that is replaced inside the warranty.
The power path is what makes this part usable in a system with a removable pack. The adapter feeds the system through the input FETs while the battery charges, and when the adapter is removed the pack takes over with a break before make sequence. The reverse protection FET stops the pack from pushing current back into the adapter input, which is a real failure mode when a charged pack is connected to an unpowered adapter lead.
- External FETs mean the current limit and the thermal budget are set by the components around the part, not by the package.
- The 600 kHz switching frequency is a compromise that keeps the inductor reasonable at 10 A without pushing switching losses too high.
- The 99.5 percent maximum duty cycle matters at low adapter voltage, where a six cell pack needs almost the full input range.
- Sleep current of 15 nA means a pack left connected to the board does not drain through the charger.
Which projects this part fits
Notebooks and mobile internet devices, industrial and medical equipment, handheld terminals, portable instruments and any product that charges a multi cell pack from an adapter and needs a system rail at the same time. Medical carts and bedside monitors are the classic case, because the pack must keep the system alive while the adapter is swapped. The medical device component page covers the documentation we hold for charger parts in medical builds, and power management cross reference lists the controllers we stock alongside it.
The three set-point equations and a worked example
Three resistor networks set everything that matters on this controller, and the document prints the equations for all three. The charge voltage is 2.1 V times one plus R2 over R1, where R2 sits from the feedback pin to the battery and R1 from the feedback pin to ground. The charge current is the ISET1 voltage divided by 20 times the sense resistor. The adapter current is the ACSET voltage divided by 20 times the adapter sense resistor.
| Set point | Equation from the document | Example |
| Charge voltage | 2.1 V times one plus R2 over R1 | R2 300 kOhm, R1 100 kOhm gives 8.4 V |
| Fast charge current | ISET1 divided by 20 times the sense resistor | 2 V on ISET1 with 10 mOhm gives 10 A |
| Adapter current limit | ACSET divided by 20 times the adapter sense resistor | 0.8 V on ACSET with 10 mOhm gives 4 A |
| Precharge and termination | Set by ISET2, fast charge must be at least twice termination | Termination 0.3 A needs a fast charge above 0.6 A |
The worked numbers show why the 2.1 V reference is not a problem for divider accuracy: at 8.4 V out the divider carries about 21 uA, which is low enough to leave connected in a battery powered product, and the ratio is a simple 4 to 1. They also show why ISET2 is the pin that gets forgotten. A charge current reduced for a smaller adapter without a matching ISET2 change breaks the rule that fast charge must be at least twice the termination current, and the pack then terminates early at a partial charge that looks like a weak cell.
The first article list for this controller has four items: charge voltage at the pack terminals after termination, charge current at two set points, adapter current limit with the system loaded, and the sleep transition when the adapter is removed, which should show the system moving to the battery without a reset. The last item is the one that catches a power path that was assembled with the wrong FET polarity, a fault that otherwise only appears when a customer unplugs the adapter.
Questions that come up before a purchase order is released
Why use a controller instead of an integrated charger?
Because the power level and the cell count do not fit inside one package. A six cell pack at 8 A needs external FETs for thermal reasons and for the voltage rating, and an integrated part would either be limited to 2 A or need a much larger body. The controller keeps the loop and the protection integrated and leaves the heat to parts that can be cooled.
Can the charge voltage be changed for a different chemistry?
Yes, through the feedback divider. Because the reference is 2.1 V, the divider ratio changes with the pack voltage, and the same board can be built for four, five or six cells by changing two resistors. That is also the reason the divider tolerance has to be checked on the first article rather than assumed.
What happens if the thermistor is missing?
The TS pin sits on a divider that expects the thermistor. If it is open, the pin voltage moves outside the window and the charger treats the pack as out of temperature range, so it does not charge. That is the safe direction, but it looks like a dead charger on the bench, so the thermistor is one of the first things to check when a board will not charge.
How SUPERB handles this line
We supply the BQ24616RGER together with the external FETs, inductor and sense resistors as a matched kit, because the current limit and the thermal result depend on all of them. If a product is moving from an integrated charger to this controller, the FET selection and the current set resistors are the parts that decide whether the 10 A claim holds. Send the pack specification and the adapter rating and we will price the complete power stage. Start from the one stop BOM sourcing page.