Contact Us

AMC3330DWER

Brand: Texas Instruments
Texas Instruments AMC3330DWER is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AMC3330DWER — Power Management & Signal Chain | Superb Automation

AMC3330DWER

Texas Instruments — Power Management & Signal Chain

Product Overview

The AMC3330DWER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

AMC3330DWER: a plus or minus 1 V isolated amplifier with the supply inside

AMC3330DWER is a precision isolated amplifier with a plus or minus 1 V input, a fixed gain of 2.0, a reinforced barrier, and an isolated DC to DC converter that lets the high side run from a single 3.3 V or 5 V low side rail. The DWE suffix is the 16 pin wide body SOIC, 10.3 mm by 10.3 mm, which is the package that carries both the signal barrier and the power barrier.

The input is built for voltage rather than current. It has a high input impedance, it is intended to connect directly to a resistor divider, and the plus or minus 1 V range maps a divider ratio rather than a shunt drop. That is the difference between this part and the 250 mV current sensing family: same barrier concept, different front end, different job.

The accuracy rows are the reason it exists. Gain error is 0.2 percent maximum, offset error 0.3 mV maximum, nonlinearity 0.02 percent maximum, and the drifts are 45 ppm per degree and 4 microvolts per degree respectively. Those are instrumentation grade numbers, and they are what a servo drive or a photovoltaic inverter needs when the voltage measurement feeds a control loop rather than a display.

Functionprecision isolated amplifier for voltage sensing
Input rangeplus or minus 1 V
Input impedancehigh, intended for a resistor divider
Fixed gain2.0
Gain error0.2 percent maximum
Gain drift45 ppm per degree maximum
Offset error0.3 mV maximum
Offset drift4 microvolts per degree maximum
Nonlinearity0.02 percent maximum
Transient immunity85 kilovolts per microsecond minimum
Isolation, VDE6000 VPK reinforced per DIN EN IEC 60747-17
Isolation, UL4250 VRMS for one minute per UL1577
Supply3.3 V or 5 V single supply on the low side
Diagnostic outputdedicated pin for converter fault reporting
EMCmeets CISPR-11 and CISPR-25
PackageSOIC, DWE body, 16 pins, 10.3 mm by 10.3 mm
Carrier2000 pieces on a large reel
Moisture levellevel 3 at 260 degrees, 168 hours floor life
Operating rangeminus 40 to plus 125 degrees Celsius

The divider is half the measurement

With a plus or minus 1 V input and a gain of 2, the output swings plus or minus 2 V around a low side common mode. To measure a 1000 V rail, the divider has to bring 1000 V down to 1 V, which is a ratio of 1000 to 1, and the top resistor then dissipates about a watt at 1 mA. That is a real thermal problem, and it is why high voltage sensing dividers are usually made from several resistors in series rather than one.

The input impedance of the amplifier is high enough that a 1 Mohm divider is not loaded, and the offset current is small enough that the error it produces across 1 Mohm stays under a millivolt. That is the arithmetic that lets a divider of a few hundred kilohms be used instead of a few tens, which cuts the dissipation by an order of magnitude.

The divider tolerance is the dominant error term in most circuits. A pair of 0.1 percent resistors gives a ratio error of 0.14 percent worst case, which is comparable to the amplifier's own 0.2 percent gain error. Spending on a better amplifier than this one while using 1 percent divider resistors is spending in the wrong place.

Single supply, and what the internal converter changes

A conventional isolated voltage measurement needs a floating supply on the high side, usually a small transformer based converter with its own regulatory evidence. This part removes that: the converter is inside the package, its output powers the high side only, and the isolation evidence is part of the device certification.

Two consequences follow. The first is that the high side cannot power anything else, so a circuit that also needs an isolated supply for, say, a gate driver still needs that supply. The second is a diagnostic output that reports converter faults, which is a feature a discrete converter rarely provides and which a safety concept can use to distinguish a measurement fault from a real overvoltage.

The converter switching frequency and its harmonics are the emission source to watch. The document states that the part meets CISPR-11 and CISPR-25, which means the reference board arrangement with the recommended decoupling passes. A board that changes the decoupling capacitor value or moves the capacitor away from the pin is no longer measuring the certified arrangement.

Reading the output and keeping the common mode honest

The output is differential, centred on a common mode that is set by the low side supply. On a 3.3 V rail that centre is around 1.65 V and the swing is plus or minus 2 V, which means the output clips against the rail before it reaches the input limit. On a 5 V rail the headroom is comfortable. A board that runs the low side at 3.3 V and expects the full plus or minus 1 V input to appear at the output will find the top of the range compressed, and the fix is either a 5 V low side or a converter with a wider input range.

The receiving converter has to be differential, or the common mode has to be removed before a single ended converter sees it. A differential converter with a 2.5 V reference and a plus or minus 2.05 V input range is the natural partner, because the amplifier output fits it almost exactly and the two share the same reference. A single ended converter needs an instrumentation amplifier in between, which spends the accuracy the isolated amplifier just bought.

Where a precision voltage channel is the requirement

The document lists isolated voltage sensing in motor drives, photovoltaic inverters, power delivery systems, EV charging infrastructure and battery energy storage. The common requirement is a control loop that closes on a measured voltage, not a monitor that displays one.

A photovoltaic inverter is the case where the accuracy pays. The maximum power point tracking loop steers the array voltage by small increments, and a measurement with 0.5 percent error produces a tracking error that costs energy every hour of the day. The 0.02 percent nonlinearity and the 45 ppm drift are what keep the loop stable across a cabinet temperature swing.

A battery energy storage system is the case where the isolation pays. The stack voltage is hundreds of volts, the controller is earthed, and the measurement has to hold its calibration for a decade. The reinforced barrier and the diagnostic output are what make that credible to a certification body.

Our amplifier cross reference page lists the isolated amplifier families by input range and barrier rating, and the obsolete part cross reference hub page covers the case where an older isolated amplifier goes end of life and the replacement has a different pinout.

The last item worth checking is the reference. The amplifier's gain is fixed and its accuracy depends on the internal reference, which the document specifies over the full temperature range. A receiving converter that uses a different reference introduces a second drift term, and on a control loop the two terms add. Sharing one reference between the amplifier's digital side and the converter removes that addition at the cost of a single trace.

Three questions buyers ask about this string

Is it pin compatible with the 250 mV current sensing family? No. Different body, different pin count and different input structure.

Does the gain of 2 limit the input? It sets the output swing: plus or minus 1 V in becomes plus or minus 2 V out. The input range is fixed and cannot be changed by external resistors.

What happens if the high side supply fails? The diagnostic pin reports the fault. The output then sits at a defined level rather than floating, which is what lets the controller distinguish a failed measurement from a genuine zero.