AMC1204BDWVR
Product Specifications
AMC1204BDWVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The AMC1204BDWVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AMC1204BDWVR isolated delta sigma modulator with a 250 millivolt input for shunt current measurement
The AMC1204BDWVR is the B member of the AMC1204 family, a one bit digital output isolated delta sigma modulator clocked at up to 20 megahertz, with a 250 millivolt input optimised for a shunt resistor and a silicon dioxide barrier certified to 4250 volts peak on the B grade. Where the analogue output families hand the controller a voltage, this part hands it a bit stream and leaves the filtering to the digital side.
The reason to choose a modulator is what the digital filter can do with the stream. The document prints a signal to noise ratio of 84 decibels minimum, total harmonic distortion of 80 decibels maximum, integral nonlinearity of 8 least significant bits maximum and a gain error of 2 percent maximum, and states that with an appropriate external filter the effective number of bits reaches 14 at a data rate of 78 thousand samples per second. That combination gives a current measurement with a defined bandwidth, a defined latency and no analogue filter to drift.
Key parameters taken from the AMC1204BDWVR document
| Output | One bit digital stream, isolated |
| Clock | External clock input, up to 20 MHz, which also sets the sampling rate |
| Input range | Plus or minus 250 mV, optimised for a shunt resistor |
| Signal to noise | 84 dB minimum |
| Distortion | Total harmonic distortion 80 dB maximum |
| Linearity | Integral nonlinearity 8 LSB maximum |
| Gain error | 2 percent maximum |
| Effective resolution | 14 ENOB at 78 kSPS with a suitable external digital filter |
| Isolation | 4250 V peak basic on the B grade per DIN VDE V 0884-11, 3005 V RMS for one minute per UL1577 |
| Working voltage | 1200 V peak, transient immunity 15 kV per microsecond |
| Supplies | 5 V analogue on the high side, 3 to 5.5 V digital on the low side |
| Reference | Internal, which removes the external reference the analogue output families need |
| Package | SOIC-16, this code is the wide body tape and reel version |
| Immunity | High electromagnetic field immunity, with the application report referenced in the document |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The external clock is the engineering decision that catches teams out. Because the clock comes from the low side controller, the isolation barrier carries the clock as well as the data, and the pair has to be routed together with the barrier clearance applied to both. A board that clocks the part from a local oscillator on the high side removes the clock from the barrier but then needs a synchronisation scheme, because an unsynchronised modulator produces a stream the controller cannot filter at a fixed rate.
The digital filter is part of the measurement, not an afterthought. The order of the filter sets the latency, and the latency sets how fast the current loop can respond. A third order sinc filter gives a clean result with a few samples of delay; a first order filter responds faster and lets more of the switching ripple through. The document references the filter board and the vendor tooling, and the practical rule is to fix the loop rate first and then choose the filter that meets the noise target inside that latency budget.
The internal reference removes a component and a drift term, which is why the gain error of 2 percent is stated as a single figure. On the analogue output families the reference and the amplifier each contribute, and the two have to be calibrated together. Here a single gain calibration at the current level of interest corrects the whole chain, and because the modulator has no analogue output stage there is no offset drift from an output amplifier to add to the budget.
Isolation on a modulator part is a two sided problem: the high side needs 5 volts and the low side 3 to 5.5, and the barrier carries data and clock. The transient immunity of 15 kilovolts per microsecond is higher than the analogue output families because the digital signal is more robust to a fast common mode step, but the barrier routing still has to keep the two grounds apart by the printed distance on every layer. A modulator on a board with a poorly split plane produces a stream with bit errors, and the symptom looks like noise in the current reading rather than like an isolation problem.
- Clock frequency and jitter at the modulator pin, with the clock routed across the barrier at the production length.
- Noise and effective resolution with the filter the firmware actually implements, at the loop rate the product uses.
- Gain calibration at the current level of interest, with the shunt and the thermal drift included in the check.
- Bit error rate with the switching node active, which is the test that finds a barrier routing problem.
- Latency from a current step at the shunt to a change in the filtered value, measured through the real chain.
- High side supply current and the isolated supply's ability to hold 5 volts at the modulator's switching rate.
Which projects this part fits
This part fits motor drive and servo current control where the loop runs in the controller, solar and storage inverter current measurement, charger current regulation, and any board that wants the current measurement to be a digital number at a defined rate with no analogue filter to tune. For SUPERB customers building drives and power conversion hardware it is the choice when the controller has no spare analogue input, or when the measurement has to be shared between a control loop and a protection function without a second sensor.
Questions that come up before a purchase order is released
What replaces the analogue output stage?
A digital filter in the controller. The modulator produces a bit stream at the clock rate and the filter turns it into a number at the loop rate. That moves the analogue engineering problem into firmware, which is an advantage for teams with strong firmware and a disadvantage for teams expecting a drop in part.
Is the clock really needed on the high side?
The part is clocked from outside, and the clock is normally supplied by the low side controller and crosses the barrier with the data. That means the barrier has to carry both signals and the board routing has to treat them as a pair. The alternative, a local clock on the high side, needs a synchronisation scheme and is usually avoided.
How accurate is the current reading in practice?
The gain error of 2 percent maximum is the dominant term and it is a single calibration away from being much smaller. The noise and linearity figures then set the resolution at the bandwidth the filter allows. In a drive that regulates torque, the calibrated result is normally better than the accuracy of the shunt, which is where the next error comes from.
What is the difference between the standard and B grade?
The isolation rating and the certification figures, with the B grade carrying the higher peak isolation and the corresponding UL and VDE entries. The signal path specification is printed for the family. The choice is set by the safety requirement of the product rather than by accuracy, and it should be made from the certification file.
Can several modulators share one clock?
Yes, and that is the usual arrangement in a three phase drive, where one clock drives three modulators and the controller filters three streams in step. Sharing the clock keeps the samples aligned, which matters when the three currents are used together to compute a vector.
How SUPERB handles this line
We supply the AMC1204BDWVR from original tape and reel with lot traceability, and we confirm the grade and the body before the parts are booked to a line. Where the board is comparing isolated measurement options, the power management cross reference page sets the analogue output and modulator families side by side. Where continuity and second sourcing are the questions, component obsolescence management covers the options, and incoming inspection plan covers the arrival checks.