Contact Us

AMC1200SDUBR

Brand: Texas Instruments
Texas Instruments AMC1200SDUBR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AMC1200SDUBR — Power Management & Signal Chain | Superb Automation

AMC1200SDUBR

Texas Instruments — Power Management & Signal Chain

Product Overview

The AMC1200SDUBR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

AMC1200SDUBR: the gullwing body of a 250 mV isolation amplifier

AMC1200SDUBR is a fully differential isolation amplifier with a plus or minus 250 mV input, a fixed gain of 8 and a silicon dioxide barrier between the input and the output side. The DUB suffix is the 8 pin SOP body with gullwing leads, 9.50 mm by 6.57 mm, which is the wide body that keeps the creepage distance across the package at 7 mm. The plain AMC1200 barrier is rated 4000 VPEAK; the B grade of the same device is rated 4250 VPEAK, and the two share one document.

The part exists for shunt based current sensing. A shunt of a milliohm or two produces tens of millivolts, the amplifier multiplies that by 8 and shifts it onto a low side referenced output, and the controller reads a differential signal that is proportional to current without sharing a ground with the power stage. The offset is 1.5 mV maximum referred to the input, which on a 250 mV full scale is 0.6 percent, and the nonlinearity is 0.075 percent maximum, so the amplifier is not the limiting element in a typical drive.

The figures below are from SBAS542D, revised July 2015, and from the orderable addendum. The document has one property that matters more than any single number on the first page: it prints the insulation coordination data, the clearance and creepage for both bodies, and the surge rating against IEC 61000-4-5. On a mains connected product those rows are what a safety reviewer reads first.

The two bodies are not interchangeable on a safety file

The DUB body is the SOP with gullwing leads and 7 mm of clearance and creepage. The DWV body is the SOIC with 8 mm of both, and it costs more board area: 5.85 mm by 7.50 mm of body against 9.50 mm by 6.57 mm. The isolation voltage is the same on paper for a given grade, but the working voltage rating and the pollution degree assumptions in the safety file are tied to the package geometry, not to the device name.

That is why a substitution from DUB to DWV is a safety file change even when the silicon is identical. The creepage figure is what the standard checks, and 7 mm against 8 mm can move a product from one installation class to another. We treat the body suffix as part of the safety identity of the part, and our pin to pin cross reference page spells out the fields we compare before calling two isolation parts interchangeable.

Functionfully differential isolation amplifier
Input rangeplus or minus 250 mV, clipping at 320 mV
Fixed gain8, with 0.5 percent initial gain error
Bandwidth60 kHz minimum, 100 kHz typical
Nonlinearity0.075 percent maximum at 5 V low side supply
Offset error1.5 mV maximum, 0.2 mV typical drift of 10 microvolts per kelvin
Output noise3.1 mV RMS over the specified band
Isolation, AMC12004000 VPEAK per UL1577 and VDE V 0884-10
Isolation, AMC1200B4250 VPEAK
Working voltage1200 VPEAK
Transient immunity10 kV per microsecond minimum
Surge rating6000 V per IEC 61000-4-5
High side supply4.5 V to 5.5 V, 8 mA maximum
Low side supply2.7 V to 5.5 V, 6 mA maximum at 3.3 V
PackageSOP, DUB body, 8 pins, 9.50 mm by 6.57 mm
Clearance and creepage7 mm minimum in the DUB body
Carrier350 pieces on a large reel
Moisture levellevel 4 at 260 degrees, 72 hours floor life
Operating rangeminus 40 to plus 105 degrees Celsius

Three hundred and fifty pieces on a reel is the quiet scheduling fact

Most of the parts on this page ship 2500 or 3000 to a reel. This one ships 350. The DWV body ships 1000. The reason is mechanical: the gullwing SOP body is wider than a standard 8 pin carrier pocket at the same pitch, so fewer parts fit on a 330 mm reel.

For a production line that is not a problem, because a reel of 350 still covers a shift. For a prototype or a repair order it changes the economics, because the minimum buy is a full reel and the reel is small enough that partial quantities are available from stock. It also means the feeder setup happens four times more often per thousand parts, which a contract assembly house will price into the assembly quote if nobody mentions it.

The moisture level is the second scheduling fact. Level 4 with 72 hours of floor life is the tightest rating in this family, and it is tighter than the level 2 of the SOIC body. A line that opens a reel on Monday and finishes it on Thursday has to bake or re-seal. The floor life clock starts at the bag, not at the feeder, and it is worth writing the open date on the reel label.

What the fixed gain of 8 means at the shunt

The input range is plus or minus 250 mV and the gain is 8, so the output swings plus or minus 2 V around a common mode that is set by the low side supply: 1.29 V nominal on a 3.3 V rail and 2.55 V on a 5 V rail. That arithmetic decides the shunt value. A 1 milliohm shunt at 100 A produces 100 mV, which uses 40 percent of the input range and leaves room for a 250 percent overload before clipping.

The choice of 250 mV rather than a wider range is deliberate. A smaller full scale means the amplifier's own offset and noise are a smaller fraction of the signal at rated current, which is where accuracy matters. The price is that a fault current ten times rated will clip, and the controller sees a saturated reading rather than a proportional one. On a drive that is acceptable because the fault path is handled by a comparator, not by the current loop.

The output common mode follows the low side supply, so an ADC with a 3.3 V reference sees a signal centred at 1.29 V. That is inside the input range of most differential converters, and it means the amplifier and the converter can share a rail. On a 5 V low side the centre moves to 2.55 V, which is fine for a 5 V converter and too high for a 3.3 V one.

Where the isolation actually earns its place

The document lists shunt based current sensing in motor control, green energy, frequency inverters and uninterruptible power supplies. In each case the shunt sits on a node that moves with the switching, and the controller sits on a ground that must not move with it.

A photovoltaic inverter is the clearest example. The shunt is in the return path of a bridge that switches at 16 kHz or higher, and the common mode steps by hundreds of volts on every edge. The 10 kV per microsecond transient immunity and the 108 dB common mode rejection are what keep the current reading usable through that edge, and the 1200 V working voltage is what keeps the barrier intact over the life of the product.

A battery test system is the second. The shunt is at a potential that walks from 0 to 800 V as the pack charges, and the controller is earthed. An isolation amplifier is the only practical way to measure the current without a floating supply for every channel.

Our amplifier cross reference page covers the isolation amplifier families we hold against this function, and the medical device component sourcing page covers the parts we keep for isolated patient connected circuits, where the same barrier argument applies with a stricter standard.

Three questions buyers ask about this string

Is the DUB body a drop in replacement for the DWV body? Same silicon and same pin functions, different footprint and different creepage. The safety file has to be rechecked, so the answer is no for a qualified product.

Why is the operating range only minus 40 to plus 105? The barrier and the package set that limit, not the amplifier. A part that needs 125 degrees has to come from a different family.

Can two channels share one low side supply? Yes, the low side is ground referenced and the output common mode is set by that rail. Two amplifiers on one rail need separate decoupling, and the high side supplies must stay separate because each one floats with its own shunt.