AMC1100DUBR
Product Specifications
AMC1100DUBR
Texas Instruments — Power Management & Signal Chain
Product Overview
The AMC1100DUBR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AMC1100DUBR isolated amplifier with a 250 millivolt input for shunt current measurement
The AMC1100DUBR is a precision isolation amplifier in the gullwing eight pin body, with a 250 millivolt input range optimised for shunt resistors, a fixed gain of 8 with 0.5 percent accuracy, and a silicon dioxide barrier certified to 4250 volts peak of basic isolation. The output is differential and its common mode is set automatically to the low side supply, which means the part works with a 3.3 volt or a 5 volt controller without a level shift stage.
The numbers that decide whether this part suits a board are the errors rather than the isolation headline: nonlinearity of 0.075 percent maximum at 5 volts, offset error of 1.5 millivolts maximum, noise of 3.1 millivolts RMS typical, and an input bandwidth of 60 kilohertz minimum. For a motor current loop those are comfortable. For a Class 0.2 energy meter they are not, and the document is clear enough that the comparison can be made before a board is built.
Key parameters taken from the AMC1100DUBR document
| Input range | Plus or minus 250 mV, optimised for a shunt resistor |
| Gain | Fixed 8, with 0.5 percent accuracy |
| Nonlinearity | 0.075 percent maximum at 5 V |
| Offset error | 1.5 mV maximum |
| Noise | 3.1 mV RMS typical |
| High side current | 8 mA maximum at 5 V, the supply on the isolated side |
| Bandwidth | 60 kHz minimum input bandwidth |
| Common mode rejection | 108 dB |
| Low side supply | 3.3 V operation, with the output common mode set to that rail |
| Isolation | 4250 V peak basic per DIN VDE V 0884-11, 3005 V RMS for one minute per UL1577 |
| Working voltage | 1200 V peak, transient immunity 2.5 kV per microsecond minimum |
| Temperature | Fully specified over minus 40 to plus 105 C, the extended industrial range |
| Package | SOIC-8 wide body DWV and gullwing-8 DUB, this code is the gullwing body |
| Certifications | VDE, UL and CSA component acceptance, with the working voltage printed for each |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The gain of 8 with a 250 millivolt input means the output spans about two volts, which is why the low side supply matters. On a 3.3 volt rail that leaves headroom of a volt and a quarter, enough for the offset and for the recovery of the output stage, and it is the configuration the document shows for a 3.3 volt controller. On a 5 volt rail the same part gives more headroom and better linearity, at the cost of a rail the controller may not have.
Shunt selection is where the accuracy is decided, and it is a thermal decision as much as an electrical one. A 1 milliohm shunt at 100 amps dissipates ten watts, which is more than most boards can carry; a 0.1 milliohm shunt dissipates a watt and produces ten millivolts, which is a small fraction of the 250 millivolt range and loses resolution. The part's 1.5 millivolt maximum offset sets the floor: below about 15 millivolts of signal the offset dominates, so the shunt should be chosen to give at least that much at the lowest current of interest.
Isolation is a certification statement and board routing statement at the same time. The document prints the creepage and clearance the barrier needs, and the board has to keep the isolated and non isolated copper apart by that distance on every layer, including the plane layers beneath the part. A board that routes a signal across the barrier under the package passes a bench test and fails a safety review, and the fix at that stage is a board spin.
The gullwing body is the one to choose when the assembly house has seen solder cracking on the wide body SOIC after thermal cycling. The gullwing leads flex and take the strain that the wide body joints otherwise absorb, which matters on a board that sees power cycling every day. The trade is a slightly larger footprint and a slightly different thermal path, neither of which changes the electrical specification.
- Offset and gain at 25 degrees and at the extremes of the printed range, with the shunt the product will use.
- Noise on the output with the shunt at zero current, measured over the bandwidth the controller actually uses.
- Linear fit over the full input range, compared against the 0.075 percent nonlinearity limit.
- Isolation barrier creepage and clearance on every copper layer, against the printed requirement.
- Common mode transient response with the switching node active, not with a static high voltage.
- Output settling after a step at the input, against the 60 kilohertz bandwidth figure and the loop rate.
Which projects this part fits
This part fits motor drive and inverter phase current measurement, solar and energy storage string current, uninterruptible power supply output sensing, battery charger current control and energy metering front ends at the accuracy class this part supports. For SUPERB customers building power electronics it is one of the two standard ways to measure a high side current with galvanic isolation, the other being a modulator with a digital filter, and the choice between them is decided by the loop rate and by whether the controller has an analogue input to spare.
Questions that come up before a purchase order is released
Can this part measure a 400 volt DC bus current?
Yes, provided the barrier working voltage of 1200 volts peak is respected and the creepage is laid out to the printed requirement. The input side sits at the bus potential and the low side at controller ground, and everything about the board routing, including the isolated supply, has to treat that as a safety boundary rather than as a signal path.
What is the difference between the DWV and DUB bodies?
Both are eight pin isolated amplifier bodies, one wide body SOIC and one gullwing. The electrical specification is the same, the footprint and the mechanical strain relief differ, and this code is the gullwing version. On a board with heavy thermal cycling the gullwing leads are the more forgiving of the two.
Does it need an isolated supply on the high side?
Yes. The barrier isolates the signal, not the power, so the high side needs its own supply referenced to the shunt. In practice that is a small isolated DC to DC converter or a bootstrap arrangement, and the 8 milliampere maximum high side current is the number that sizes it.
How does the accuracy compare with a Hall sensor?
The offset and gain numbers are tighter and do not drift with the field of a nearby conductor, which is why an isolated amplifier is preferred where the current has to be controlled rather than merely detected. The trade is that a shunt dissipates power and needs isolation, while a Hall sensor does not, so the decision is usually made on the current level and the isolation requirement together.
Is a two point calibration enough for production?
For most drive applications yes, because the offset and the gain are the two dominant errors and both are stable. Where the product carries an accuracy class, a three point calibration that includes a mid scale reading is the safer routine, because a nonlinearity problem shows up as a bow rather than as an offset.
How SUPERB handles this line
We supply the AMC1100DUBR from original tape and reel with lot traceability, and we confirm the body against the code before the parts reach a line. Where the board is comparing isolated measurement options, the power management cross reference page lists the families by input range and output type. Where continuity over a long production life is the question, component obsolescence management covers the options, and incoming inspection plan covers the incoming checks.