INA105KU/2K5
Product Specifications
INA105KU/2K5
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA105KU/2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA105KU/2K5: Unity gain difference amplifier with 72 dB of rejection in a SOIC-8
INA105KU/2K5 is a precision difference amplifier in the eight pin SO body with a fixed gain of one, 72 dB of common mode rejection as a minimum, 0.025 percent gain error and a 1 MHz bandwidth in a SOIC-8 body of 8 pins. The INA105 is a monolithic difference amplifier built from an operational amplifier and four thin film resistors, with a fixed gain of one and no external components. It is specified on plus and minus 15 V supplies and operates from plus and minus 5 V to plus and minus 18 V with derated performance, with a common mode range of plus and minus 20 V at the nominal supply. Offset is 500 uV maximum with 20 uV per degree of drift, and the input survives 10 V beyond either supply as long as the current is limited to 1 mA.
Order code and package
| Order code | INA105KU/2K5 |
| Gain | 1 V per V, fixed |
| Common mode rejection | 72 dB minimum |
| Gain error | 0.025 percent maximum |
| Supply voltage | plus and minus 5 V to plus and minus 18 V |
| Common mode range at plus and minus 15 V | plus and minus 20 V |
| Package | eight pin SOIC, SO body |
| Packing | 2500 pieces per reel |
Electrical parameters that decide the application
| Gain drift | 5 ppm per degree maximum |
| Non linearity | 0.001 percent maximum |
| Bandwidth | 1 MHz typical |
| Offset voltage | 500 uV maximum |
| Offset drift | 20 uV per degree maximum |
| Quiescent current | plus or minus 1.5 mA typical, plus or minus 2 mA maximum |
| Settling time to 0.01 percent | 5 us on a 10 V step |
| Settling time to 0.1 percent | 4 us on a 10 V step |
| Input overvoltage | 10 V beyond either supply, input current limited to 1 mA |
| Output current | 10 mA minimum at the specified swing |
Points to check before this part goes on a BOM
A gain of one is a constraint that is easy to board around and easy to get wrong. The part cannot amplify, so the signal has to arrive at a level the converter can use, and the common mode range of plus and minus 20 V is the space in which it may arrive. A shunt signal of 50 mV stays 50 mV, which on a 3.3 V converter is 1.5 percent of the range. A board that needs the signal at a volt has to add a second stage, and the offset of that second stage then enters the budget that the 105 uV of this part was chosen to protect.
Seventy two decibels of rejection is a factor of 3981. A 10 V common mode step at the input therefore appears as 2.5 mV at the output, which is five times the maximum offset of the part. That is the arithmetic that decides whether a difference amplifier or an instrumentation amplifier is the right choice: an instrumentation amplifier with 100 dB of rejection turns the same step into 100 uV, and it costs a second amplifier and a gain resistor. At 60 Hz the 105 is adequate; near a switching node at 100 kHz the rejection falls with frequency and the 72 dB figure no longer describes the behaviour.
The offset of 500 uV is large compared with a modern zero drift amplifier, and its drift of 20 uV per degree is larger still. Over a 40 degree rise that drift alone is 800 uV, which is more than the offset. That combination rules the part out of a measurement that has to resolve a millivolt, and it is perfectly adequate for a control loop that works at a volt. The reason to still choose it is the resistor matching: four discrete resistors at 0.1 percent give at best 66 dB of rejection, and their tracking over temperature is worse than the thin film network on the die.
The 1 MHz bandwidth is quoted at unity gain, so it is the full closed loop bandwidth of the difference amplifier rather than a gain bandwidth product. A 10 V step settles to 0.01 percent in 5 us, which is a slew limited behaviour rather than a small signal one. In a multiplexed data acquisition system the settling time sets the channel to channel acquisition window, and 5 us per channel limits a 16 channel scan to about 12 kHz, before the converter's own conversion time is added.
The input protection is 10 V beyond either supply with a 1 mA current limit, which is a specification that assumes the current is limited by something other than the part. On a plus and minus 15 V supply the input can reach plus and minus 25 V, and at that point the internal diodes conduct. A 24 V industrial signal applied to the input of a 15 V supplied part is inside the rating only if the series resistance limits the current, so the resistor is part of the board rather than a protection afterthought.
The quiescent current of 1.5 mA typical on a plus and minus 15 V supply is 45 mW, which is more than some signal chains can afford on a battery product. The part is specified at plus and minus 15 V and operates down to plus and minus 5 V, where the quiescent current is lower and the common mode range shrinks with the supply. A plus and minus 5 V board has plus and minus 10 V of common mode range in principle, and the datasheet's typical characteristics show how much of that survives at the extremes.
The eight pin SOIC with a fixed gain has no external components, which is a reliability argument as much as a cost one. There is no resistor divider to drift, no ratio to match and no node to pick up noise. On the other hand there is no way to trim the gain, so a system that needs 0.1 percent of gain accuracy has to either select the part or calibrate the channel in production, and the second option is what most teams do because the calibration also removes the offset of the following stage.
Where this order code fits
This order code belongs on battery cell formation and test equipment, servo drive position feedback, level transmitters and string inverters, where a differential signal from a remote sensor has to be converted to a single ended one without a resistor network on the board. It is also the part chosen where the four resistors have to track: the thin film network on the die matches to a fraction of the tolerance that four discrete 0.1 percent resistors achieve, and that matching is what holds the rejection over temperature. Teams comparing it with a neighbouring part start from our Amplifier Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
Why use this instead of four resistors and an op amp? The four resistors on the die are laser trimmed to a ratio and track over temperature, which is what gives 72 dB of rejection. Four discrete 0.1 percent resistors give about 66 dB at room temperature and less over temperature, because their temperature coefficients do not match. The part also removes the settling and stability questions that a discrete difference stage brings.
Can it measure a 50 mV shunt directly? It can, but the 500 uV offset is 1 percent of that signal and the 20 uV per degree drift adds another 1.6 percent over a 40 degree rise. That is not a measurement, it is an indication. A shunt signal at that level belongs on an instrumentation amplifier or a dedicated current sense amplifier with a much lower offset.
Does it work on a single supply? The part is specified on bipolar supplies and operates from plus and minus 5 V to plus and minus 18 V. A single supply board has to deal with the fact that the output cannot swing below its negative rail, so a signal that goes to zero at the input drives the output to the rail and loses the bottom of the range. A single supply difference amplifier is the right part for that case.
What limits the common mode range? The supply voltage. At plus and minus 15 V the range is plus and minus 20 V, which is 5 V beyond either rail. At plus and minus 5 V it shrinks with the supply. A signal that sits at 24 V needs a supply that supports it, and this part is not the one for a high side measurement above 20 V.
SUPERB holds and sources this amplifier line against the exact order code, with the reel, date code and country of origin stated on the offer. When a signal chain has to move to a second part, the Component Lead Time Solutions page sets out the checks that separate a working substitute from one that fails on the bench.