VBP18R35S
Product Specifications
VBP18R35S
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBP18R35S from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBP18R35S: 800 V and 35 A in a TO247
The VBP18R35S is a single N channel MOSFET rated at 800 V drain to source with a plus or minus 30 V gate window and a threshold of 3.5 V. It carries 35 A and its on resistance is 110 milliohm at a 10 V gate. The silicon is a multi epitaxial super junction structure and the body is the TO247 through hole package.
One hundred and ten milliohm at 800 V and 35 A is a converter switch for a real power level. At 10 A it drops 1.1 V and dissipates 11 watt; at 20 A it is 44 watt. The 35 A rating assumes a case at 25 C and a die that can take the current, which in practice means a heatsink with forced air or a cold plate.
The voltage class covers a 400 V rectified bus, a 480 V industrial rail and the primary side of a three phase input supply. It also covers a 600 V solar string with margin for the open circuit voltage at low temperature, which is the case that catches people out with a 650 V part.
Key data for the VBP18R35S
| Configuration | Single N channel |
| Package | TO247, three lead through hole with tab |
| VDS | 800 V |
| VGS | Plus or minus 30 V |
| Vth | 3.5 V typical |
| ID | 35 A |
| RDS(on) at 10 V | 110 milliohm |
| Technology | Multi epitaxial super junction |
| Gate charge | Not published on the catalogue page |
| Body diode | Intrinsic, with an abrupt recovery that needs a snubber in a bridge |
| Thermal path | Tab to heatsink, with an insulating pad on an earthed sink |
| Isolation | TO247 tab is the drain, so the pad and the mounting hardware carry the voltage rating |
One hundred and ten milliohm at 800 V is a loss curve
At 5 A the loss is 2.75 watt and a clip on sink is enough. At 10 A it is 11 watt and the sink has to be a real one. At 20 A it is 44 watt, which is a heatsink with a fan. At 35 A it is 135 watt, which no TO247 sheds in air and which is the reason the 35 A figure is a die limit rather than an operating point.
That curve is what separates this part from a 270 milliohm device at the same voltage. The lower resistance part carries twice the current for the same loss, and it costs more because it is a larger die. A converter that only ever delivers 5 A is better served by the higher resistance part, which is smaller, faster and cheaper, and it will run cooler at that current because the switching loss is lower.
The switching loss at 800 V is not small. Even at 5 A a 100 kHz converter with 40 nC of gate charge spends about 4 watt per transition pair at 400 V of swing. That is more than the conduction loss at that current, and it is why offline converters with a low current output run at 50 to 70 kHz rather than at 500.
Eight hundred volts and the spacing it demands
The TO247 tab is the drain at the full bus potential plus the switching overshoot, which on a 400 V bus can reach 600 V in a hard switched bridge. The insulating pad under the tab, the screw or the clip, and the distance from the tab to the gate lead are all part of the insulation coordination.
The gate loop is the other half. A 110 milliohm die at 800 V switches a large voltage in a short time, and the gate return has to be separate from the power return or the source inductance will lift the gate and produce a false turn on. A Kelvin source connection, where available, or a short gate loop with a resistor at the gate pin, is the standard answer.
Thermally, a TO247 with a 1.5 degree per watt sink and a good pad handles 11 watt with a junction about 60 degrees above ambient. Beyond that the sink grows faster than the part.
Planning supply for a converter programme
Converter programmes tend to run for years and to buy the same part for the whole life, which means the planning question is about the buffer rather than about the price. Our one stop BOM sourcing page covers how a bill of material is grouped so that a single shortage does not stop a line.
At 800 V the number of true equivalents is smaller than at 60 V, and a substitute usually means a different die with a different gate charge. That is a re-qualification, not a substitution, and it is worth recording before it is needed rather than after a part goes on allocation.
The sourcing side of this part is covered on the material requirements planning. For an 800 V switch that a converter programme holds for years, that page covers how the buffer is set and reviewed.
Questions we get on this code
Is 35 A continuous? No. At 110 milliohm the continuous current is about 10 A with a heatsink and 5 A without one.
Can it run on a 600 V solar string? Yes, because the string voltage rises at low temperature and 800 V leaves margin where 650 V does not.
Does the body diode need a snubber? In a hard switched bridge, yes. The recovery is abrupt and the overshoot at 800 V is significant.
How is it packed? TO247 normally ships in tubes with a fixed count. We confirm the tube count and the date code on the quotation.