VBE2609
Product Specifications
VBE2609
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBE2609 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBE2609: a -60 V P channel at 6 milliohm and 70 A
The VBE2609 is a single P channel MOSFET in TO252 rated at -60 V drain to source, plus or minus 20 V on the gate, -70 A of drain current and a threshold of -3 V. The catalogue gives 8 milliohm in the first resistance column and 6 milliohm in the second, on trench silicon.
A 6 milliohm P channel at 60 V is a high side switch that a logic output can drive directly, with no charge pump, no bootstrap and no floating driver. That is the whole point of a P channel at this voltage and current.
Seventy amps in a DPAK is the usual case temperature figure. At 6 milliohm it corresponds to 29 W of conduction loss, so the working current is far lower and is set by the tab and the copper.
Key data for the VBE2609
| Configuration | Single P channel |
| Package | TO252, DPAK, exposed drain tab |
| VDS | -60 V |
| VGS | Plus or minus 20 V |
| Vth | -3 V |
| ID | -70 A |
| RDS(on) | 8 milliohm and 6 milliohm in the two catalogue columns |
| Technology | Trench |
| Body diode | Intrinsic, cathode at drain |
| Thermal path | Drain tab to copper or heatsink |
| Gate charge | Not published, large die means large charge |
| Typical use | 48 V battery disconnect, reverse polarity switch, high side load control |
| Isolation | None, the tab is the drain |
Why a P channel at 60 V still makes sense
An N channel has a better figure of merit at every voltage, so the reason to use a P channel is the drive. A high side N channel needs a gate voltage above the drain, which means a charge pump or a bootstrap, and both add parts, cost and a failure mode. A P channel needs only a pull down to ground, and a resistor can hold it off when the control is unpowered.
At 60 V the penalty is acceptable because the currents are moderate and the resistance of a 6 milliohm P channel is already the same as a 100 V N channel. At 200 V or above the penalty becomes too large and the industry moves to an N channel with a driver.
The catch is the gate window. With the source at 48 V and the gate pulled to ground, the gate sees -48 V, which is well past the 20 V limit. A P channel on a 48 V rail therefore needs a resistor divider, a zener or a dedicated driver that limits the gate to source voltage, and that requirement is easy to miss.
Seventy amps and six milliohm
At 6 milliohm and 20 A the loss is 2.4 W, and with 40 degrees per watt that is a 96 C rise. At 30 A it is 5.4 W, which needs a heatsink. At 10 A it is 0.6 W, which is easy.
So the working current is 15 to 25 A with good copper and a heatsink, and the 70 A rating belongs to a case at 25 C. For a battery disconnect that closes once and carries a continuous load, 15 to 20 A is the honest figure.
In a reverse polarity protection position the part is on continuously and the body diode is in the path during a fault, so the diode has to survive the fault current for the time it takes a fuse to open. The catalogue page does not give a forward surge rating for the diode, so a fuse and a part with a known surge curve are needed.
A P channel at this current also needs a look at how the part behaves when the battery is connected in reverse. In a reverse polarity switch the body diode conducts in the fault condition and the channel is held off, so the diode carries the fault current until a fuse opens. The diode forward voltage at 50 A is around 1.2 V, which is 60 W in a DPAK for the milliseconds before the fuse goes. That is survivable for a short pulse and not for a long one, and it is the reason the fuse rating and the diode surge rating are chosen together rather than separately.
Where the part fits and where it does not
It fits a 48 V battery disconnect, a reverse polarity switch on a 24 or 48 V input, a high side load control that has to be simple, and a power path in a product that cannot afford a charge pump. It does not fit a 48 V rail without a gate clamp, and it does not fit a load that switches faster than a few kilohertz.
Our date code management page covers how a large die power part is tracked through storage, which matters when a 6 milliohm P channel sits on a shelf for a year before it is used.
The sourcing side of this part is covered on the excess inventory management. For a large die P channel bought in programme quantities, that page covers how excess is identified and how age is handled.
Questions we get on this code
Can a 3.3 V pin drive it on a 48 V rail? Not directly. The gate has to be pulled 10 V below the source for the 6 milliohm figure, and it must never go more than 20 V below. A divider plus a zener, or a small P channel driver, does the job.
Which column is 10 V? The catalogue prints two values without repeating the gate voltage. For a part of this class the 6 milliohm figure belongs to the higher gate voltage and 8 milliohm to the lower one. We confirm both from the data sheet.
Is the body diode in the way? In a battery disconnect it conducts when the battery is inserted the wrong way, which is the point. In a load switch it conducts from load to supply while the channel is off, which may not be what the circuit expects.
What should a purchase order carry? Part number, TO252, reel size and date code. We confirm availability on the quotation.