VBC6N2005
Product Specifications
VBC6N2005
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBC6N2005 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBC6N2005: two 20 V N channels with a common drain in TSSOP8
The VBC6N2005 is a common drain N channel pair in a TSSOP8 body rated at 20 V, with a plus or minus 12 V gate window, a threshold window of 0.5 to 1.5 V, a current figure of 11 A and resistances of 7 milliohm at 2.5 V and 5 milliohm at 4.5 V.
Common drain is the configuration that makes a pair into a bidirectional switch. The two channels share their drain connection inside the package, and each source comes out separately, so the pair conducts in both directions when both gates are on and blocks in both directions when both are off, because each body diode is opposed by the other channel.
Seven and five milliohm are low numbers for a 20 V pair, and 11 A in a TSSOP8 with an exposed pad is consistent with them. The body is wider than an SOP8 and the pad is on the underside, which is where the heat goes.
Key data for the VBC6N2005
| Configuration | Two N channels, common drain |
| Package | TSSOP8 with exposed pad, 0.65 mm pitch |
| VDS | 20 V |
| VGS | Plus or minus 12 V |
| Vth | 0.5 to 1.5 V |
| ID | 11 A |
| RDS(on) at 2.5 V | 7 milliohm |
| RDS(on) at 4.5 V | 5 milliohm |
| Technology | Trench |
| Gate charge | Not published on the catalogue page |
| Body diodes | Opposed through the common drain, which is what gives the block |
| Thermal path | Exposed pad, both dies on one pad |
| Gate drive | Two gates, one per channel, both referenced to their own source |
Five milliohms and a bidirectional block
In a common drain pair used as a bidirectional switch, the current passes through both channels when on, so the on resistance of the switch is the sum, 10 milliohm at 4.5 V and 14 at 2.5 V. A 5 A load therefore dissipates 250 mW in the pair at 10 milliohm, which is modest for a body with an exposed pad.
When off, each channel's body diode is oriented so that the other channel blocks it, and the pair holds off in both directions up to the 20 V rating. That is the property a battery path needs: a single N channel in a positive rail can never block reverse current because its diode conducts.
The gate drive is the complication. Each gate is referenced to its own source, which sits at a different potential during conduction, so a single gate signal cannot drive both unless the two sources are at the same potential. In a battery path the two sources sit on either side of the switch, and one of them is the pack and the other the system, so the gates have to be driven independently or through a charge pump arrangement.
Eleven amps, a pad and a 12 V gate window
At 10 milliohm total and 5 A the loss is 250 mW. At 11 A the loss in the pair is 1.2 W, which the exposed pad can pass on a good copper landing and not in still air on a small one. The 11 A figure applies to one channel conducting; in a bidirectional switch both conduct, so the working current is lower.
The 12 V gate window matches the low voltage nature of the part. It is comfortable with a 5 V or 10 V drive and not tolerant of a 12 V rail that rings. The 0.5 to 1.5 V threshold window means the part turns on from a low voltage rail and needs the gate pulled down firmly to stay off.
The threshold window is wide, which matters in a bidirectional switch because both channels have to be off at the same time. A channel that turns on early, at 0.5 V, wastes current through the pair before the other channel is fully on, and the switching sequence has to tolerate that.
A common drain part usually ties the exposed pad to the drain, which makes the copper under the body a live node rather than a ground. That changes the board in three ways: the pour under the part cannot be shared with a ground plane, the vias in it carry the switch potential to the inner layers, and any test point or probe pad on that copper is at the switch node. The data sheet confirms the connection, and until it is read the pad should be treated as live and kept clear of everything else.
Where it fits
It fits a battery isolation switch on a single cell or a 5 V pack, a bidirectional load switch, a USB power path, and a protection stage where a true block is required. It does not fit a 12 V rail with transients, and it does not fit a bridge where the two drains need to be separate.
Our vendor consolidation page covers which lines stay dual sourced, and a common drain pair is usually a single source item, which argues for holding it with a second source or a buffer.
The sourcing side of this part is covered on the supplier scorecard. For a common drain pair that is a single source item, that page covers how a source is scored across a programme.
Questions we get on this code
Can one gate drive both channels? Only if the two sources sit at the same potential. In a battery path they do not, so each gate needs its own drive.
What is the on resistance of the switch? The sum of the two channels, 10 milliohm at 4.5 V and 14 at 2.5 V.
Does it block in both directions when off? Yes, that is the reason for the common drain configuration.
Is the pad connected to the drain? In a common drain part it usually is, and the data sheet answers it. If it is, the pad is a live node and the copper under it has to be treated as such.