VBA1615
Product Specifications
VBA1615
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBA1615 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBA1615: a 60 V N channel at 12 A in SOP8
The VBA1615 is a single N channel MOSFET in an SOP8 body with a 60 V drain to source rating, a plus or minus 20 V gate window, a 1.7 V threshold, 12 A and 15 milliohm at 4.5 V against 12 milliohm at 10 V, on trench silicon.
Sixty volts is where the application set changes. A 48 V telecom or PoE rail, a 36 V battery pack, a 24 V system with a wide transient window and a 12 V system with a hot plug event all want a part in this class, and none of them can use a 30 V device with confidence.
The price of the extra voltage is visible in the resistance. The 4.5 V column at 15 milliohm is close to the 30 V part at 29 milliohm for the same current, which sounds like a win until the die area is considered: a 60 V die that reaches 12 milliohm at 10 V is a much larger piece of silicon than a 30 V die at the same figure, and the difference comes out of the cost.
Key data for the VBA1615
| Configuration | Single N channel |
| Package | SOP8, surface mount, 1.27 mm pitch |
| VDS | 60 V |
| VGS | Plus or minus 20 V |
| Vth | 1.7 V |
| ID | 12 A |
| RDS(on) at 4.5 V | 15 milliohm |
| RDS(on) at 10 V | 12 milliohm |
| Technology | Trench |
| Gate charge | Not published on the catalogue page |
| Body diode | Intrinsic, reverse recovery has to be checked on the data sheet |
| Thermal path | Eight leads, no exposed pad |
| Avalanche rating | Not published on the catalogue page, do not assume one |
A 20 per cent gap between the gate columns
Fifteen against twelve is a narrow spread, and narrow spreads carry information. A die whose resistance barely moves between 4.5 V and 10 V is either already close to full enhancement at 4.5 V or has a channel whose geometry limits the current rather than the gate field. Either way, the practical reading is that a 5 V gate drive gets most of the available performance out of this part, and a 10 V rail adds a little margin rather than a different behaviour.
That makes the part friendly to systems that only have 5 V or 12 V available. It also means the gate resistor and the driver current matter more than the gate voltage, because the switching loss is set by how fast the gate crosses the plateau, and the plateau height is fixed by the die.
At 12 A and 15 milliohm the conduction loss is 2.16 W, which is above what an SOP8 can pass in still air. The honest continuous figure is nearer 6 to 8 A, where the loss sits between 540 mW and 960 mW and the junction stays inside its limit on a board with reasonable copper under the leads.
Sixty volts, a hot plug and the drain spike
A 48 V rail is the natural home for this part, and the thing that kills parts on a 48 V rail is not the steady voltage but the cable inductance during a plug event. A metre of cable at roughly 1 microhenry per metre, interrupted at 10 A in 100 ns, produces 100 V across the switch before anything else happens, and no 60 V die survives that without help.
The usual answers are a transient suppressor across the input, a capacitor close to the switch, and a controlled turn on that limits the di/dt. All three act on the same physics: the spike is the inductance times the current slope, so either the inductance is clamped or the slope is slowed. A part rating is not a substitute for either.
The body diode matters in the same application. On a reverse polarity event the diode conducts and the loss is the forward drop times the current, which is a different thermal problem from channel conduction and is limited by the diode area rather than the channel. The catalogue page does not publish a forward voltage curve for the diode, so the figure has to come from the data sheet.
On a 48 V rail the switching loss is usually the larger term, and it is the one the catalogue page cannot help with. The loss is set by the gate charge, the driver current and the drain voltage at the moment of crossover, and the only way to see it is to measure the switch node with a short ground lead and a low capacitance probe. A part whose 4.5 V and 10 V columns are 20 per cent apart usually has a moderate gate charge, so a 10 ohm gate resistor and a driver that can source half an amp is a reasonable first attempt. A snubber across the switch node is the second lever, and it trades efficiency for a quieter waveform rather than for a colder die.
Where it fits
It fits a 48 V hot swap stage at a few amps, a 36 V battery disconnect, a boost converter switch in a 12 V to 48 V stage, and a relay replacement on an industrial 24 V rail. It does not fit a 48 V rail without clamping, and it does not fit a load that freewheels into the switch node without a diode or a synchronous partner.
Our component lead time solutions page covers what can be done when a 60 V part in this body is quoted long, which for this class usually means accepting a different body size rather than a different die.
The sourcing side of this part is covered on the obsolete part cross reference hub. For a 60 V part in a small body that rarely has a second source, that page covers the route when the original ends.
Questions we get on this code
Will it work at 48 V nominal? Yes, with 12 V of margin over the rail and none over a plug spike. Clamp the input and keep the loop short.
Is the part avalanche rated? Not according to the catalogue page, and a trench die without a published rating should not be used to absorb inductive energy. Add a clamp or a freewheel path.
Can it replace a 60 V part in a DPAK? Electrically often yes, thermally often no. The DPAK has a tab that dumps heat into the board, and the SOP8 does not.
What does a quotation need? Part number, body, quantity and the rail it switches. The last item lets us confirm that the class is right before the price is discussed.