A 0.80 mm connector pin is drawn into a 0.90 mm finished hole. The boards arrive and pins will not enter. The tightest hole in the lot measures 0.855 mm after plating, which is inside the plus or minus 0.075 mm band on the drilled hole and still smaller than the pin needs.
Nothing was wrong except that the drawing gave a finished hole with no tolerance. The chart below is the arithmetic between that number and the bit.
Four numbers behind one hole
The drill diameter is what the bit cuts in the panel, a nominal size with a tolerance. On this line the hole position and diameter are held to plus or minus 0.075 mm, or 0.05 mm on a press fit position.
The plating wall is copper deposited inside the hole, 20 micrometres minimum on each side. Two walls close the hole by at least 0.04 mm on diameter, and where the line plates heavier the hole closes further.
The finished hole is what the pin, the lead or the screw sees, and it is always smaller than the drill. That is the number on the drawing and the number an inspector checks with a pin gauge.
The tolerance is what most drawings leave out. A finished hole given as 0.90 mm with no band can arrive at 0.83 mm and still meet every other note.
The chart
Each step is the finished hole plus 0.05 mm, which covers the 0.04 mm the plating removes at the 20 micrometre floor and leaves a margin. The drill column is a starting point, not a house standard.
| Finished hole (mm) | Drill to run (mm) | Where it is used |
|---|---|---|
| 0.15 | 0.20 | Smallest mechanical hole on the line; below this the laser covers 0.075 to 0.15 mm |
| 0.20 | 0.25 | Fine pitch via |
| 0.25 | 0.30 | Via inside a dense BGA fanout |
| 0.30 | 0.35 | Standard signal via |
| 0.40 | 0.45 | Via, small axial lead |
| 0.50 | 0.55 | Smallest plated slot on the line is 0.50 mm |
| 0.60 | 0.65 | Resistor and capacitor lead |
| 0.80 | 0.85 | 0.8 mm connector pin, loose fit |
| 0.90 | 0.95 | 0.8 mm pin, close fit |
| 1.00 | 1.05 | 1 mm pin, header |
| 1.20 | 1.25 | Relay and terminal pin |
| 1.50 | 1.55 | Terminal, wire lead |
| 2.00 | 2.05 | Screw terminal, standoff |
| 2.50 | 2.55 | Mounting hole |
| 3.00 | 3.05 | Mounting hole |
| 3.20 | 3.25 | M3 screw clearance |
Mechanical drilling covers 0.15 to 6.35 mm, so the chart stops there.
When the finished hole is a hard minimum
A connector pin, a press fit pin or a locating pin has a size it cannot go under. For those the drill cannot be picked from the chart alone, because the low end of the band is what matters.
Take a finished hole that must not measure less than 0.90 mm. The drilled hole may come in 0.075 mm under nominal, and the plating removes at least 0.04 mm on diameter, so the nominal drill has to be 0.90 plus 0.04 plus 0.075, which is 1.015 mm. A chart entry of 0.95 mm would put the low end of that band at 0.835 mm, under the pin, which is exactly the failure above.
On a press fit position the hole tolerance tightens to plus or minus 0.05 mm, and the pin maker publishes an insertion and retention window. Send both and the drill is chosen inside the overlap.
Where the drill has to leave the chart
Aspect ratio limits how small a hole can go in a thick board. Ten to one is the standard line and twenty five to one the high layer line, so a 3.2 mm board at 0.30 mm is already past ten to one. That trade off is worked through under how small a hole can be drilled in a thick board.
Annular ring limits the other end. A via needs 3.5 mil of ring at 1 oz and a component hole 8 mil, so a hole cannot grow past its pad. On a BGA the pad floors at 10 mil with HASL and 8 mil with ENIG.
Holes that need a flat bottom or a controlled depth are counterbored or countersunk after drilling, which is a separate operation with its own tooling and tolerance, covered under counterbore and countersink.
What the drill list should say
Give the finished diameter and its tolerance, not the drill size. A drawing that names a drill removes the room to hold the finished hole.
State plated or non plated for every hole. A non plated hole is drilled at final size and does not close, so the same number means two different tools.
Where holes sit against a datum, say which datum. Position is held to plus or minus 0.075 mm against the same reference as the drill file, which is what drill registration is measured on.
What SUPERB PCBA works to
Boards are built to print from the supplied Gerber, stack up and drill list, from 1 to 20 layers on the FR-4 line up to 68 layers on the high layer line, HDI at 1 to 3 stages, finished thickness 0.6 to 3.2 mm standard. Mechanical drilling covers 0.15 to 6.35 mm and laser drilling 0.075 to 0.15 mm. Hole wall copper is 20 micrometres minimum, plated through holes are held to plus or minus 0.075 mm and 0.05 mm on press fit, non plated holes to plus or minus 0.05 mm, and slots to plus or minus 0.10 mm. Plated slots start at 0.50 mm and non plated at 0.80 mm. The full envelope is on the PCB capability page.
What to send with the enquiry
- The drill list with finished diameter and tolerance per hole, plated or non plated.
- The stack up with finished thickness, so the aspect ratio of every hole can be checked before the order.
- Any press fit or connector position with the pin maker's insertion window.
- Whether the finished hole is a nominal or a hard minimum, because that decides how much tolerance the drill has to absorb.
Questions buyers ask
Why is the hole smaller than the drill I specified?
Because plating closes it. Copper is deposited on the wall, so the finished hole is smaller than the drilled hole by at least 0.04 mm on diameter, and more where the line plates heavier. The drawing should give the finished size, not the drill.
Can a 0.90 mm hole be guaranteed not to go under 0.90?
Yes, if the drill is chosen for the low end of the band rather than the middle. That means a nominal drill around 1.02 mm, not 0.95 mm, and it is the first thing checked when a connector will not seat.
Does the chart work for laser drilled holes?
No. Laser drilling covers 0.075 to 0.15 mm with 0.05 mm available and is used for microvias in HDI builds, where the pad and the dielectric decide the hole. The chart covers mechanical holes.
Next step
Send the drill list with finished diameters, tolerances and plated status, plus the stack up and any press fit positions. SUPERB PCBA returns the drill and plating allowance for each hole, the aspect ratio of the tightest one and the finished window the lot will be inspected against.