A six up panel reaches the router, the operator drops it on the fixture pins, and the first board comes out with the connector edge 0.3 mm long. Nothing changed in the Gerber. The tooling hole was called out at 3.0 mm and drilled at 3.0 mm, but it came out plated, so the finished hole closed to 2.9 mm on a 3.0 mm pin. The panel sat high on one side and every board followed the same error, scrapped after routing rather than after drilling.
A tooling hole is the cheapest feature on a panel drawing and the one that decides whether the panel can be held still. It is also the feature most often copied from an old drawing without a note, which is why it fails quietly and late.
Where a tooling hole sits in the build
Three processes use the same hole. The router locates the panel on it before cutting the profile. AOI and flying probe register the panel against the CAD data on it. The SMT line and the functional fixture clamp the assembly on it. Each wants a round, unplated, accurately placed hole, and each fails differently when the hole is wrong: the router cuts a profile that is offset yet still in tolerance to itself, AOI reports false calls along one side, and the fixture pushes the assembly out of position.
That is why the hole belongs to the panel and not to the product. It sits in the border, outside the board outline, and appears on no drawing of the finished board. When a customer sends a single outline with no panel, the hole is added at panelisation, and the note that travels with it is what keeps it round and clear.
Tooling hole, mounting hole and fiducial are three different jobs
| Feature | What it is for | What goes wrong if it is treated as one of the others |
|---|---|---|
| Tooling hole | Locating the panel on router pins, AOI, fixture | Plated or undersized, the pin no longer enters and every cut follows the error |
| Mounting hole | Fixing the finished assembly to a chassis | Used as a tooling hole, its tolerance is read against the product, not the panel |
| Fiducial mark | Optical registration for paste and placement | Used as a mechanical stop, the copper dot is crushed and the camera no longer sees it |
| Plated slot | Clearance or connection on the finished board | Used as a tooling feature, plating changes the width the pin has to pass |
| Board edge | Final outline after routing | Hole placed too close, the cut opens into it and the pin loses its seat |
The first two rows cause most of the trouble. A mounting hole is dimensioned from the product datum and usually carries plating and a finish, because a screw sits in it. A tooling hole is dimensioned from the panel datum and must carry neither. Sending one drawing that labels both as 3.2 mm holes invites the plated program, and the note is the only thing that separates them.
What the panel drawing has to state
- The word non plated, on the hole callout and not left to a general note.
- The diameter the pin has to pass, with its tolerance, not the drill size.
- The datum the position is measured from, and that datum should be the panel outline the router uses.
- The number of holes and their distribution. Three holes with one offset is the pattern that stops a panel being loaded the wrong way round.
- Where the hole may not sit: inside the rail, clear of the profile cut and clear of copper that will be exposed later.
On a panelised job the rail is the space that carries the hole, and the rail has a floor. Below about 3 mm the clamps have nothing to hold and the hole has no material around it, so hole and rail are agreed together rather than one after the other. The relationship between rail width and breakaway is covered under panelisation for assembly.
How the hole is held through drilling and routing
A hole drilled with the plated program comes out with copper on the wall unless it is drilled in a second pass after plating, or protected through the cycle. The note on the drawing selects the pass. A drawing without the note defaults to whichever program the panel was already set for, which is how a 3.0 mm hole becomes a 2.9 mm hole after plating.
Position is the second half. The hole has to be drilled against the same datum the router will use, otherwise the pin fits and the profile still lands off centre. Registration between drilling and the outer layers is checked on the coupon, and the same logic is set out under drill registration.
What SUPERB PCBA works to
Panels are built to print from the Gerber, the stack up and the mechanical drawing. FR-4 runs 1 to 20 layers, up to 68 layers on the high layer line, at 0.6 to 3.2 mm finished thickness standard. Tooling holes are drilled non plated and held to plus or minus 0.05 mm, position to plus or minus 0.075 mm against the panel datum, with the profile at plus or minus 0.15 mm and copper at least 0.20 mm from the routed edge. Mechanical drilling covers 0.15 to 6.35 mm. Panels run up to 622 by 1092 mm with a minimum rail of 3 mm, and warpage is held to 0.75 percent, which matters here because a panel that bows away from the pins loses the registration the hole was meant to give. The full table is on the PCB capability page.
What to send with the enquiry
- The panel drawing with the tooling holes marked, or the board outline if the panel is built here.
- The pin diameter and the fixture or router model, if it is already fixed.
- The rail width and the breakaway method, so hole and rail are checked together.
- Whether the same hole doubles as a mounting hole on the assembly, and which tolerance governs.
Questions buyers ask
Can the tooling hole be plated if the fixture pin is insulated?
It can, but there is no reason to. Plating narrows the hole, adds a finish that wears, and gives the pin a surface that can bridge to copper if the mask is thin at the edge.
Does the tooling hole count as a non plated hole in the schedule?
Yes. It is called out as non plated, held to plus or minus 0.05 mm, and listed with the other non plated holes, so a buyer can see it was drilled to the note rather than assumed.
What if the assembly drawing already has a hole in that position?
Then it is a mounting hole and it stays in the product. The tooling hole moves into the rail at panelisation, which keeps the product drawing unchanged and the panel pinned.
Next step