A twelve layer board passes electrical test, yet the buried vias in one quadrant sit 45 micrometres off the pad centre and the ring on the tightest layer is down to 2 mil. The drill program is correct and the panel is square. What moved is the inner layer stack, and the offset only shows when the board is X-rayed against the tooling holes.
Drill registration is the alignment between the hole and what it has to connect. Artwork, tooling and the press set it before the drill touches the panel, so it is measured on a coupon, not argued after a reject.
Four alignments that share one name
Buyers say registration and mean one of four things. Sorting them out first decides who fixes the problem:
- Drill to copper. Each hole has to land inside the pad on every layer it passes through.
- Layer to layer. Inner layer patterns have to sit on one axis after lamination, which sets whether a buried via connects or misses.
- Drill to drill. Depth controlled holes, back drill in particular, have to start and stop on the right layer.
- Panel to tooling. The panel has to sit on the same pins at drill, imaging and routing, or every step adds its own shift.
A board can be perfect on the first and fail the second. That is the common case on high layer counts, and it is why an X-ray of the finished panel says more than a hole position check alone.
Where the offset comes from
Registration error is not random. Each cause leaves a different pattern, and the pattern tells you where to look.
Uniform shift on every layer. The panel moved on the tooling pins, or the drill origin is off. One correction at the drill machine settles it.
Shift that grows from the centre outwards. The artwork did not match the shrink of the laminate. Each prepreg and copper combination moves a different amount in the press, so the film has to be scaled to match. A 0.05 percent error across a 500 mm panel is 0.25 mm at the edge, far outside any ring allowance.
One layer out, others correct. That layer was exposed or laminated against a different tooling reference.
Shift that appears only after reflow. Moisture expansion and stress release at solder temperature. The board measures inside tolerance cold and drifts when heated, so the coupon is read after a reflow pass.
Plotting the offset vector per layer and per panel position separates these four. A spread that changes with position usually arrives with a thickness spread across the panel, which belongs to copper balance.
The numbers that decide accept or reject
Each value below is measured on a different feature, so a report with one number does not cover the other three:
| Feature | Working target | How it is checked |
|---|---|---|
| Layer to layer registration | Plus or minus 0.025 to 0.06 mm on high layer and HDI builds | X-ray of the registration coupon, cross section at the worst layer |
| Hole position to pad | Plus or minus 0.075 mm | X-ray drill target check, hole inspection, cross section |
| Plated hole diameter | Plus or minus 0.075 mm, plus or minus 0.05 mm on press fit holes | Pin gauge, cross section |
| Non plated hole and slot | Plus or minus 0.05 mm, plus or minus 0.10 mm on slots | Pin gauge, optical measurement |
| Annular ring left after drill | 3.5 mil on vias at 1 oz, 4.5 mil at 2 oz, 8 mil on component holes | Cross section, AOI after drilling |
| Back drill stub | 0.25 mm or less, depth held to plus or minus 0.05 mm | Cross section on the stub coupon |
The ring is what is left after every other error has been spent, which is why it is the number a buyer should ask for. Two builds can hold the same hole position and differ in ring if one carries a smaller pad.
How registration is held through the process
Three controls do most of the work. Tooling: a four slot pin system on every panel, with X-ray targets drilled into the inner layers so each layer is exposed to the same reference. Scaling: the artwork is compensated for the measured shrink of that stack up, rechecked on the first panel of every new material combination. The coupon: a registration coupon on the panel border, read by X-ray and cross section. On HDI, laser vias are drilled stage by stage against targets opened after each press, so registration is measured between presses. Back drill depth is a separate setting with its own coupon.
What SUPERB PCBA works to
Boards are built to print from the buyer's Gerber and stack up. The published envelope covers 1 to 20 layers on the FR-4 line and up to 68 layers on the high layer line, HDI at 1 to 3 stages, finished thickness 0.6 to 3.2 mm standard and up to 12 mm extended, mechanical drilling from 0.15 to 6.35 mm and laser drilling from 0.075 to 0.15 mm with 0.05 mm available. Aspect ratio is 10 to 1 as standard and up to 25 to 1 on the high layer line, and plated copper in the barrel is 20 micrometres or more.
Layer to layer registration is held to plus or minus 0.025 to 0.06 mm on those builds, and hole position to plus or minus 0.075 mm, which leaves ring on a 0.45 mm pitch BGA pad at 8 mil with ENIG. The full envelope sits on the PCB capability page, and the stage by stage sequence on the HDI build page.
When a stack up needs a hole smaller than the drill can hold in that thickness, the limit is the aspect ratio rather than the bit, covered under how small a hole can be drilled in a thick board.
What to send with the enquiry
- Gerber per layer, plus the drill file with plated and non plated holes separated.
- The stack up with prepreg type and count, finished thickness and tolerance.
- The via table: pad diameter, finished hole size and the ring needed on the tightest layer.
- Any back drill hole, with the layer it must stop on and the stub limit.
Questions buyers ask
How much layer shift is acceptable?
It depends on the pad and the ring you need, not on a fixed number. Send the pad diameter and the minimum ring on the tightest via and the allowed shift follows. On a 0.45 mm pitch BGA the answer is tighter than on a 1.27 mm pitch connector.
Can registration be held after reflow?
That is the number that matters for assembly, and it is measured after a reflow pass on the coupon. A cold measurement is optimistic, especially on a thick board or one with a large copper plane on one side.
Next step
Send the Gerber, the drill file, the stack up and the ring you need on the tightest via. SUPERB PCBA returns the achievable registration band for that build, the drill sizes it will hold in that thickness and the coupon plan for the lot, so the tolerance is agreed before the first panel is drilled.