ADM3053BRWZ-REEL7
Product Specifications
ADM3053BRWZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM3053BRWZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADM3053BRWZ-REEL7: isolated CAN transceiver with an integrated isolated supply
The ADM3053BRWZ-REEL7 is a CAN physical layer transceiver with both the signal isolation and an isolated DC to DC converter on the die, in the 20-lead wide body SOIC on tape and reel. It runs from a single 5 V supply on the bus side, with VIO at 5 V or 3.3 V on the logic side, provides 2.5 kV RMS of isolation, complies with ISO 11898, and moves data at up to 1 Mbps across a bus that can carry 110 or more nodes. The value is the single package: a board that would otherwise need a transceiver, a digital isolator and an isolated supply gets all three with one isolation barrier to qualify.
Published values
| Parameter | Value |
|---|---|
| Isolation | 2.5 kV RMS signal and power, UL 1577 for one minute |
| Working voltage | 560 V peak per VDE 0884-17, approval pending at the time of the datasheet revision |
| Bus standard | ISO 11898, CAN physical layer |
| Data rate | Up to 1 Mbps |
| Supplies | VCC 5 V, VIO 5 V or 3.3 V |
| Node count | 110 or more nodes on one bus |
| Common mode transient immunity | Above 25 kV per microsecond |
| Unpowered nodes | Do not disturb the bus |
| Protection | Current limiting, thermal shutdown, slope control for emissions |
| Other approvals | IEC/EN/CSA 62368-1, IEC/CSA 61010-1, CQC GB4943.1 |
| Temperature range | Minus 40 C to plus 85 C |
| Package | 20-lead wide body SOIC |
2.5 kV is not 5 kV
The isolation rating on this part is 2500 V RMS for one minute, and the working voltage is 560 V peak. Parts in the same catalogue reach 5 kV RMS and 1000 V peak working voltage, and the difference decides which installations the part can serve. A 560 V peak working voltage covers a 400 V three phase drive bus with margin, which is the usual industrial case. It does not cover a 690 V bus or a medical application with a reinforced requirement. Because the isolated supply is inside the same barrier, the whole 2.5 kV is the number that has to be qualified, not just the data path, and a system that assumed a higher figure from a sibling part has a documentation problem rather than a component problem.
The converter inside the barrier
The isolated DC to DC converter is an isoPower stage: an on-chip oscillator drives a small transformer to move power across the barrier, and that switching is the reason the datasheet spends a paragraph pointing at the vendor's application note on controlling radiated emissions. The practical consequence is that the isolated side of the board is a switching power supply with a small transformer, and it has to be treated as one: keep the loop area small, keep the isolated ground plane solid, and do not run sensitive analog traces under the converter. The payoff is a fully isolated CAN node that takes 5 V in on one side and needs nothing on the other except the bus and its termination.
Fail-safe behaviour on a real bus
An unpowered node does not disturb the bus, which matters in a vehicle or a machine where one module loses power while the network keeps running. Slope control on the driver edges reduces emissions at the cost of a slower edge, and that setting is a trade against the maximum data rate and the cable length. Thermal shutdown and current limiting protect the driver against a shorted bus, which is the most common field failure on a CAN line. The 1 Mbps ceiling and the 110 node count are both ISO 11898 limits for the physical layer rather than arbitrary numbers.
Isolated CAN parts in the same family
The choice between this part and a discrete transceiver plus isolator plus supply comes down to board area, certification count and how much of the isolation work the project wants to own. A part that carries signal and power through one barrier qualifier is cheaper to certify and harder to second source. The selection criteria are set out on the CAN bus transceiver selection page, the shortage route for a single line is BOM shortage recovery, and holding the whole interface set with one supplier is described on one stop BOM sourcing.