Contact Us

AD8629ARMZ

Brand: Analog Devices
Analog Devices AD8629ARMZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD8629ARMZ — Analog & Mixed-Signal ICs | Superb Automation

AD8629ARMZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD8629ARMZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD8629ARMZ: dual zero drift amplifier in an 8-lead MSOP

The AD8629ARMZ is the two channel member of the AD8628/AD8629/AD8630 auto-zero family in an 8-lead MSOP body. Two 1 uV offset channels in one 3 mm wide package are what a load cell or a bridge front end needs, because the two halves of a differential signal then sit on the same die, at the same temperature, with the same correction loop.

Published values

ParameterValue
Offset voltage1 uV typical, 5 uV maximum
Offset voltage drift0.002 uV/C typical, 0.02 uV/C maximum, -40 to +125 C
Input bias current30 pA typical, 100 pA maximum per channel
Input offset current50 pA typical, 200 pA maximum
Supply current per amplifier0.75 mA typical, 1.0 mA maximum at 2.7 V
Gain bandwidth2 MHz at 5 V, 1.8 MHz at 2.7 V
Slew rate1.0 V/us
Voltage noise density22 nV/root Hz at 1 kHz, 0.5 uV p-p over 0.1 to 10 Hz
CMRR115 dB minimum at 2.7 V, 120 dB minimum at 5 V
Large signal gain110 dB minimum at 2.7 V
Overload recovery50 us
Output swing2.68 V minimum high into 100 k at 2.7 V supply
Short circuit current10 mA typical, 15 mA maximum at 2.7 V
Package8-lead MSOP (RM-8)

Two channels on one die

The two amplifiers sit on the same silicon and share one auto-zero clock, so their offsets are corrected by the same mechanism at the same time. For an instrumentation stage built from two of these instead of one integrated in-amp, that is the practical gain: the residual offsets of the two halves track, and the difference between them stays small over temperature instead of drifting apart the way two separate packages can.

That is still not a published matching specification. A product that has to state a differential offset limit must measure it, and the data sheet will not do the work for it. What the die does guarantee is 5 uV maximum per channel, which bounds the pair at 10 uV worst case before any correlation is assumed.

1 uV offset against 2 MHz of bandwidth

Two channels at 1.0 mA maximum are 2 mA, which is 17.5 mAh over a year and too much for a coin cell but comfortable in a 4 mA loop. The 2 MHz gain bandwidth at a gain of 100 leaves 20 kHz, so a bridge channel sampled at 1 kSPS has 1 ms and settles with room to spare, while a 100 kSPS channel is limited by the 40 us time constant rather than by the converter.

The 50 us overload recovery is what to check on a multiplexed front end: a channel that is driven off scale by a fault takes 50 us to return, and a scanner that switches in 10 us per channel will read that recovery as data. Give each channel a slot longer than 50 us or clamp the input before the switch.

Why MSOP rather than SOIC

The MSOP body is half the area of an 8-lead SOIC and the lead pitch is 0.65 mm against 1.27 mm, so the same two channels take a third of the board space. The trade is rework and probing: 0.65 mm pitch is not a hand soldering job on a dense board, and the thermal resistance is higher, which matters when 2 mA runs in a hot enclosure.

Both packages come from the same die and are rated to 125 C, so the choice is mechanical. A production board at volume takes the MSOP, a prototype and a low volume instrument take the SOIC, and the analog values around the part do not change between them.

Buyers usually arrive at how to verify a drop in replacement to find the family alternatives, then use the amplifier cross reference to confirm a substitute before it is fitted; medical device components is the routine for a part that has already stopped shipping.

Two questions buyers ask

Can two channels of one AD8629 replace an instrumentation amplifier? For a DC bridge with modest common mode range, yes: two 1 uV channels build a difference stage with a CMRR set by the resistors, not by the amplifier. Where the bridge sits on a large common mode voltage, a true in-amp with trimmed internal resistors is the better answer because the resistor matching, not the amplifier offset, becomes the error.

What supply current should a two channel board budget? 1.0 mA maximum per amplifier at 2.7 V, so 2 mA for the pair, plus the load current. At 5 V the same part draws 1.1 mA per amplifier.