Contact Us

AD7740YRMZ

Brand: Analog Devices
Analog Devices AD7740YRMZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7740YRMZ — Analog & Mixed-Signal ICs | Superb Automation

AD7740YRMZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7740YRMZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7740YRMZ: A Voltage to Frequency Converter Whose Accuracy Is a Counting Question

The AD7740 is a single channel, single ended synchronous voltage to frequency converter in an 8-lead MSOP or an 8-lead SOT-23, operating from 3.0 V to 3.6 V or 4.75 V to 5.25 V at about 0.9 mA and 3 mW. It is not a converter in the usual sense: it puts out a square wave whose frequency is proportional to the input voltage, and the digital side of the system counts that frequency over a known gate time. Everything about its accuracy therefore depends on the clock and the gate, not on a conversion register, and that is what makes it useful in places where a conventional converter is awkward, such as a signal that sits on a high common mode voltage and has to cross an isolation barrier.

The transfer function is set by the external clock

An input from 0 V to VREF produces an output from 10 percent to 90 percent of the clock frequency on CLKIN, and CLKIN can come from a crystal, a resonator or a CMOS compatible source up to 1 MHz. At a 1 MHz clock the output spans 100 kHz to 900 kHz, so 800 kHz covers the full input range, which is 360 Hz per millivolt for a 2.5 V reference. Counting that output for 100 ms yields about 80,000 counts across full scale, which is 16.3 bits of quantisation, and counting for 20 ms yields about 16,000 counts, which is 14 bits. The resolution is bought with gate time, which is exactly the trade a temperature or pressure channel can usually afford and a vibration channel cannot.

Bipolar input without a charge pump

The part accepts its input to 150 mV below ground without a negative supply, and in unbuffered mode the input window is minus 0.15 V to VDD plus 0.15 V. In buffered mode the input impedance becomes very high and the window narrows to 0.1 V to VDD minus 0.2 V. The mode is a pin selection, and it decides whether the source sees a light load or a wide window: a high impedance sensor wants the buffer, a signal that can swing slightly below ground on a single supply wants the unbuffered path.

ParameterValueWhat it decides
FunctionVoltage to frequency, single channelResolution comes from the counting gate
Output span10 percent to 90 percent of CLKIN800 kHz of span on a 1 MHz clock
ClockUp to 1 MHz, crystal or CMOS sourceEvery reading is ratiometric to this clock
Input range0 V to VREF, or minus 150 mV below groundTrue bipolar sensing without a negative rail
Reference2.5 V on chip, or external from 2.5 V to VDDThe full scale follows the reference directly
Supply3.0 V to 3.6 V or 4.75 V to 5.25 VTwo narrow windows, not a continuous range
Current0.9 mA typical, 3 mWAutomatic power-down between gates is available
Buffered input0.1 V to VDD minus 0.2 V, very high impedanceLight load for a high impedance source
Package8-lead MSOP or 8-lead SOT-23Two footprints for the same die

Why a frequency output helps with isolation

A frequency can cross a barrier through a single optocoupler or a pulse transformer, while an analogue level needs either a linear isolator or a remote converter with its own supply. That is why isolating a high common mode voltage is the first application the vendor lists: the converter sits on the floating side, its output is a pulse train, and the isolated side counts pulses without needing to know anything about the floating ground. The counting clock must then come from the isolated side or be transferred across the same barrier, because the reading is a ratio of the output frequency to the gate clock, and a clock that drifts shifts the scale factor.

Where the part is the wrong answer

A frequency output needs a counter, and a counter needs time. Any requirement for simultaneous sampling, for a defined sample interval shorter than a few milliseconds, or for a reading that does not depend on a gate boundary is better served by a sigma-delta converter. Anything that needs absolute accuracy better than the reference and the clock allow is also out of reach, since both terms enter the scale factor directly. Where a build needs the isolated measurement anyway, this part plus a digital isolator is often cheaper than an isolated amplifier plus a remote converter, which is why it survives in battery monitoring and automotive sensing.

For a mixed converter BOM, the ADC and DAC cross reference page lists comparable parts, the component lead time solutions page covers allocation on small outline parts, and the how to reduce component cost page covers the counting side of the system.