AD737JRZ
Product Specifications
AD737JRZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD737JRZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD737JRZ: True RMS From a 200 mV Full Scale Input and No External Trims
The AD737JRZ is a low cost, low power true rms to dc converter with a 200 mV full scale input range, an input impedance of 10 to the twelfth ohms, and a maximum input bias current of 25 pA. It computes true rms, average rectified value and absolute value, works with signal crest factors up to 5 without external trimming, and its output is negative going, which is the difference from the AD736 whose output goes positive. The high input impedance is what lets it be connected across a high value attenuator without loading it, so a 200 V range can be built from a divider and this part without a buffer. Larger inputs are handled by scaling at the input, and the accuracy is specified without any external adjustment.
Published values
| Parameter | Value |
|---|---|
| Full scale input | 200 mV rms |
| Input impedance | 10 to the twelfth ohms |
| Input bias current | 25 pA maximum |
| Functions | True rms, average rectified, absolute value |
| Crest factor | Specified to 5 |
| External trims | None required for specified accuracy |
| Output polarity | Negative going, the AD736 is the positive going version |
| Body | Surface mount, R suffix |
| Application class | Panel meters, handheld instruments, level measurement |
Output polarity is not a detail
Because the output is negative going, a single supply system sees the converter drive toward ground as the input rises, which is convenient for a converter referenced to ground but wrong for an amplifier stage that expects a positive signal. The positive going version of the same converter exists for that case, and the two are not interchangeable on a board without accounting for the sign in firmware. Programs that migrate between the two parts discover this in the calibration step, and it is the single most common mistake around this family.
Why no external trim matters in production
An rms converter with a trim potentiometer needs an adjustment per board, a calibration fixture and a procedure that survives a supplier change. This part is specified without external trims, so the accuracy is a function of the part and not of the assembly line. For a handheld meter built in the thousands that is the difference between a two minute and a ten minute test, and it removes the drift that a potentiometer brings over life.
Where the accuracy stops and a better converter starts
The 200 mV full scale range and the crest factor limit of 5 define the application: a mains waveform, a motor current or an audio level fits comfortably, while a switching supply current with a crest factor of 10 does not. The next step up in the family is a converter with a wider dynamic range and a dB output, and the step after that is a part specified to 0.02 percent nonlinearity. Choosing between them is a matter of the crest factor of the signal and the accuracy the reading has to carry. The amplifier cross reference lists the rms converter families we supply, the medical device components page covers the patient monitor and diagnostic cases, and the lead time page shows stock positions.