Contact Us

AD694ARZ

Brand: Analog Devices
Analog Devices AD694ARZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD694ARZ — Analog & Mixed-Signal ICs | Superb Automation

AD694ARZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD694ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD694ARZ: The 4 to 20 mA Transmitter That Sets Its Own Span

The AD694ARZ is a monolithic current transmitter: it takes a voltage, buffers and scales it, and pushes a 4 to 20 mA current into a loop. The two input spans, 0 V to 2 V and 0 V to 10 V, are precalibrated and selected by pin strapping, and the on board reference can be programmed to 2.000 V or 10.000 V so the transmitter can power its own sensor bridge. Output nonlinearity is 0.002 percent typical, the output stage compliance reaches to within 2 V of the positive supply and can extend below common, and an open collector alarm flags an open loop or a noncompliant output. An external pass transistor can be added to move the dissipation out of the part and reduce self heating error, which is the difference between a 70 degree ambient and an 85 degree one in a sealed enclosure.

Published values

ParameterValue
Output4 mA to 20 mA current loop
Input spans0 V to 2 V and 0 V to 10 V, pin selectable and precalibrated
ReferenceProgrammable 2.000 V or 10.000 V
Nonlinearity0.002 percent typical
ComplianceTo within 2 V of the positive supply, extends below common
AlarmOpen collector, flags open wire or output noncompliance
Zero current control4 mA level can be switched on and off with a TTL signal
DissipationOptional external pass transistor to reduce self heating
Input bufferCan scale the input or buffer a current output DAC
BodySurface mount, R suffix, also DIP and cerdip forms

The zero and span are set by two separate mechanisms

The 4 mA point is generated internally and the span is set by the pin strapped input range, so calibrating a loop is a matter of trimming the input attenuator rather than fighting an interaction between zero and span. That separation is why a transmitter built around this part holds its 4 mA point when the span resistor drifts, and it is also why an installer can verify the zero without a pressure or temperature source: a shorted input must produce exactly 4.00 mA. The TTL input that switches the 4 mA level on and off exists for that test, and for alarm signalling in a system that reads a low loop current as a fault.

Compliance is the number that decides the loop supply

A 4 to 20 mA loop with a 250 ohm sense resistor and 100 ohm of cable needs at least 7 V of compliance at 20 mA, plus the transmitter's own drop. The published compliance to within 2 V of the supply means a 24 V loop has about 22 V available, which is comfortable; a 12 V loop has 10 V, which is only just enough once a second device is in the loop. The alarm pin reports when the output stage runs out of compliance, so a marginal loop supply shows up as an alarm rather than as a reading that is quietly 3 percent low at the top of the range.

Thermal error and the external pass transistor

At 20 mA and a 24 V loop the transmitter dissipates roughly 0.3 W, and in a sealed enclosure that is enough to shift the reference by a few tenths of a percent. Adding the external pass transistor moves most of that dissipation off the die, which is the cheapest way to buy back accuracy at high ambient. The trade is one more component and a slightly larger board area, and in a loop powered device it also has to be accounted for in the 4 mA budget. Programs that run at 25 degrees in a cabinet can skip it; programs that specify 85 degree ambient should not.

Grade and availability

The A grade in the surface mount body is the industrial order code, and the family also comes in a B grade with a tighter reference and in DIP and cerdip bodies. Because the reference accuracy and the input span calibration dominate the error budget, the grade is the first thing to pin down when a BOM is being sourced. The amplifier cross reference lists the signal conditioning families we supply, the ADI second source page covers grade equivalence, and the lead time page shows what is on the shelf.