On our FR-4 line the floor is 0.20 mm from the copper edge to the finished profile, and that is a capability limit rather than a preference. It is enough for a board that is routed, masked and never touched along the edge. As soon as the edge is V-scored, bolted to a metal chassis, slid into a housing or used as a ground contact, the working number is 0.5 mm, because the profile is allowed to move 0.15 mm either way and the copper edge travels with it.
Two tolerances explain the gap. Profile tolerance is plus or minus 0.15 mm on a routed outline, so a 0.20 mm nominal clearance is 0.05 mm at the worst position on the panel, and 0.05 mm of laminate between copper and air is a coin toss decided by where the router lands. The second is etch tolerance, plus or minus 20 percent of the feature width.
What the 0.20 mm floor is built on
The floor exists because the outline is cut after the copper is already there. A router bit of 1.6 to 2.4 mm follows the profile at 20,000 to 30,000 rpm and does three things at once: it removes laminate, it leaves a burr of copper and glass on the side the bit exits, and it opens a surface that has never been through a plating bath. Registration between the panel, the drill program and the routing program is what sets the floor, and our profile tolerance of plus or minus 0.15 mm covers panel scale, laminate movement through lamination and the routing offset together.
Copper at the edge also changes the plating step: any copper that reaches the cut line can wick plating solution under the mask edge, and it is the first place a burr forms. That is why the rule applies to pads, pours and via rings and not only to traces. A via whose ring touches the profile is a hole that gets cut open at the worst case registration.
Where the edge moves after the files are fixed
V-score is the larger mechanical risk. Scoring cuts a V into both faces and leaves a web of 0.25 to 0.50 mm, plus or minus 0.10 mm, which is snapped by hand or by a blade. The board bends before the web breaks and the strain concentrates close to the score line, so a trace running parallel to a V-cut 0.2 mm away sits inside that field. Copper work hardens: the first snap may only bend it, a later rework cycle cracks it, and the crack reads as an intermittent open.
Routing has a different risk profile. A routed edge is clean and square, but the exit side carries a burr that is taken off with a brush. A pour taken to 0.2 mm from a routed edge therefore ends up with a copper lip that brushing exposes, and an exposed lip is a short waiting for a metal housing.
Panel geometry decides how much of this reaches the customer board. Panels run to 622 by 1092 mm, with finished boards of 520 by 600 mm on 1 to 4 layers and 400 by 500 mm from 6 layers up, on a process edge of at least 3 mm. The process edge is where the burr and the worst registration live, which is why a clearance measured from the panel outline always looks better than the one the finished board has. The full list sits on the FR-4 process parameters page.
When the edge stops being mechanical
Below about 50 V the number is mechanical. Above it, the distance from copper to the edge is a creepage question and the answer comes from a table in IEC 60664-1, indexed by working voltage and pollution degree. A cut laminate edge is worse than a moulded surface because it exposes glass fibres and micro-cracks that hold moisture, and because the panel collects drilling dust and ionic residue on the same cut. On a 400 V board, 0.5 mm is the start of the conversation.
Radio boards add a third case, because a ground pour is often taken to the edge to close a cavity. That works when the edge is plated and the plating is continuous, as on a castellated module where our floor is a 0.50 mm half hole on a 0.90 mm pitch. It does not work when the pour stops 0.2 mm short of a routed edge and is expected to shield: a 0.2 mm gap along the edge of a 2.4 GHz cavity is a slot, and the pour becomes an antenna.
Three ways the clearance goes wrong
Using 0.20 mm as a universal value. It passes the fabrication review and fails in the field. The boards that fail carry a V-score line, a connector that wipes the edge or a chassis screw within 2 mm, and all three are visible on the mechanical drawing.
Running a pour to the edge for shielding. A pour 0.2 mm from a routed edge leaves a copper sliver under the mask that brushing opens, and once the sliver touches a housing the fault appears after assembly, not at goods in.
Checking the clearance against the panel. A 3 mm process edge, a route channel and a 0.15 mm profile tolerance mean the panel edge is not the board edge. A check run against the panel outline reports a number the finished board never had, and the difference shows up as breakout on the vias nearest the cut.
What SUPERB PCB holds
Published figures for the FR-4 line: trace to board edge 0.20 mm minimum, profile tolerance plus or minus 0.15 mm, V-cut at 30, 45 or 60 degrees with up to 30 cuts per panel and a remaining web of 0.25 to 0.50 mm, castellated half holes from 0.50 mm diameter on 0.90 mm spacing, minimum board 50 by 50 mm, process edge 3 mm. Boards run 1 to 20 layers on the standard line and up to 68 on the high layer count line, 0.6 to 3.2 mm thick, panel up to 622 by 1092 mm. The same figures are on the capability page, and SUPERB Assembly inherits them on the assembly drawing and the stencil.
The honest boundary: 0.20 mm is a fabrication floor and it does not shrink because one order asks for 0.1 mm. If a mechanical drawing calls for 0.1 mm to a routed edge we quote it only after a capability review on that stack. Where the edge carries a ground contact or a screw boss, we say so in the quote instead of accepting the order and scrapping the panel.
What to send with the drawing
Finished outline with its tolerance, how the board leaves the panel (routed, V-score, tab), which edges touch metal in the assembly, the highest voltage on the board and the pollution degree if it is a mains product, copper weight on the layer nearest the edge, and whether any copper is meant to reach the edge for plating. Those six items settle the clearance before the first panel, which is the only point where changing it costs nothing.