TMP113AIYBGR
Product Specifications
TMP113AIYBGR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP113AIYBGR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP113AIYBGR: a third of a degree from a six ball package
The TMP113AIYBGR is a digital temperature sensor in a six ball wafer level package measuring 1.5 mm by 1.0 mm by 0.525 mm, with an I2C interface and a supply range of 1.4 V to 5.5 V. Accuracy is plus or minus 0.3 C maximum from minus 25 to 85 C and plus or minus 0.5 C from minus 40 to 125 C, with a typical figure of plus or minus 0.1 C at 25 C.
Average current is 3.4 microamps at 4 Hz conversion and 1.4 microamps at 1 Hz, with 70 nanoamps in shutdown. That combination is aimed at products that run from a small cell and still want a real temperature reading rather than a rough one.
The device supports on demand conversion. A host that needs a reading once a minute can leave the part in shutdown and start a single conversion, which keeps the average current near the shutdown figure and makes the accuracy independent of how often the bus is polled.
Key data for the TMP113AIYBGR
| Function | Digital temperature sensor with an I2C interface |
| Accuracy | Plus or minus 0.3 C maximum from minus 25 to 85 C |
| Typical accuracy | Plus or minus 0.1 C at 25 C |
| Resolution | 0.0625 C per step |
| Supply | 1.4 V to 5.5 V |
| Current | 3.4 microamps at 4 Hz, 1.4 microamps at 1 Hz, 70 nanoamps in shutdown |
| Conversion | On demand, one shot supported |
| Package | DSBGA, 6 balls, 1.5 mm by 1.0 mm by 0.525 mm |
| Interface | I2C and SMBus compatible |
| Calibration | Production units tested against NIST traceable references |
| Temperature range | Minus 40 to 125 C operation |
| Ordering | TMP113AIYBGR, large tape and reel |
What NIST traceable calibration is worth to a customer
Every production unit is tested against a reference that traces to a national standard, and the test equipment itself is calibrated through a laboratory accredited to ISO 17025. For most consumer products that is more than the application needs, and it is paid for anyway.
For a medical device or a piece of test equipment, it is the difference between a claim and a record. A temperature reading that is part of a patient monitor or a calibration bench has to be defensible, and a sensor whose accuracy is only a typical number from a data sheet is not.
The record does not replace a system calibration. A board with a sensor, a self heating term and a thermal path still has to be validated as a system. What the traceable sensor does is remove one term from the error budget, and it removes the need to calibrate every board on the line.
Self heating, and why 1.4 microamps is not the whole number
A sensor that converts continuously warms itself. At 4 Hz with 3.4 microamps average, the dissipation is a fraction of a microwatt, and the rise above ambient is negligible. At a high conversion rate in still air, the number grows, and a sensor in a sealed enclosure with no thermal path will read its own temperature.
On demand conversion changes the arithmetic. A conversion every minute, each lasting a few milliseconds, gives an average current close to the shutdown figure and a self heating term that is effectively zero. For a battery product that reports temperature to a phone once a minute, this is the right mode.
The trade is latency. A one shot conversion has to complete before the result is valid, and the host has to wait or poll. A product that needs a reading instantly on demand should keep the part converting continuously and accept the current.
Where it fits in a build
Wearables, medical patches, battery packs, portable instruments. The 0.525 mm height matters on a board that has to fit behind a display, and the 1.4 V minimum supply matters on a product that runs from a single cell down to its cut off.
Parts at this accuracy are bought on the strength of the test record, so the receiving check is a document check as much as a measurement. The incoming inspection plan page sets out what we verify at the dock, and the safety stock planning page covers how buffer is held for a part that a build cannot run without.
The sourcing side of this part is covered on the supplier scorecard. For a part that is bought on the strength of a calibration record, that page covers how a source is scored across a programme.
Questions we get on this code
Does the accuracy hold over the full supply range? The figures are specified across 1.4 V to 5.5 V, which is why the part is useful on both a single cell and a 5 V rail.
Can it be used in a sealed enclosure? Yes, but the reading will be the temperature of the board around it. Self heating is negligible at low conversion rates, so the main error is the thermal path rather than the electrical one.
How is it addressed? Through the bus address set by the order code and the package connections. The six ball body leaves little room for address pins, so the number of devices on one bus is limited.
What happens after shutdown? The registers retain their configuration and the part returns to the same settings when it is addressed again. A one shot conversion can be started without a full reconfiguration.